Add support of modbus input registers query (#2423)

* Add support of modbus input registers query

Documentation updated according pull request.
Add support of modbus input registers query

* Update sensor.modbus.markdown

Removed some extra space.

* Update according main PR change

config option name was changed.
This commit is contained in:
LvivEchoes 2017-04-21 19:04:34 +03:00 committed by Paulus Schoutsen
parent af0537278a
commit 5e6235d80e

View File

@ -35,6 +35,8 @@ sensor:
unit_of_measurement: °C
slave: 1
register: 120
register_type: input
data_type: float
scale: 0.01
offset: -273.16
precision: 2
@ -46,8 +48,10 @@ Configuration variables:
- **name** (*Required*): Name of the sensor.
- **slave** (*Required*): The number of the slave (Optional for tcp and upd Modbus).
- **register** (*Required*): Register number.
- **register_type** (*Optional*): Modbus register type (holding, input), default holding
- **unit_of_measurement** (*Optional*): Unit to attach to value.
- **count** (*Optional*): Number of registers to read.
- **scale** (*Optional*): Scale factor (output = scale * value + offset), default 1
- **offset** (*Optional*): Final offset (output = scale * value + offset), default 0
- **precision** (*Optional*): Number of valid decimals, default 0
- **data_type** (*Optional*): Response representation (int, float). If float selected, value will be converted to IEEE 754 floating point format. default int