Documentation for OpenTherm Gateway climate platform (#6118)

* Add documentation for component climate.opentherm_gw

* Update to adhere to standards

* Changed wording from "component" to "device" as it is not a component

* Minor changes

* Add quotes

* Fix location of space
This commit is contained in:
mvn23 2018-09-08 00:04:09 +02:00 committed by Fabian Affolter
parent c8f7e3f9bb
commit 60b694bf0f
2 changed files with 61 additions and 0 deletions

View File

@ -0,0 +1,61 @@
---
layout: page
title: "OpenTherm Gateway"
description: "Control your OpenTherm Gateway from Home Assistant."
date: 2018-08-29 16:23
sidebar: true
comments: false
sharing: true
footer: true
logo: opentherm.png
ha_category: Climate
ha_release: 0.78
ha_iot_class: "Local Push"
---
The `opentherm_gw` climate platform is used to control the [OpenTherm Gateway](http://otgw.tclcode.com/) from Home Assistant.
# {% linkable_title Configuration %}
```yaml
# Example configuration.yaml entry
climate:
- platform: opentherm_gw
device: /dev/ttyUSB0
```
{% configuration %}
device:
description: "Path to OpenTherm Gateway device as supported by [PySerial](https://pythonhosted.org/pyserial/url_handlers.html)."
required: true
type: string
name:
description: The name for the device within Home Assistant.
required: false
type: string
default: OpenTherm Gateway
precision:
description: "The desired precision for this device. Can be used to match your actual thermostat's precision. Supported values are `0.1`, `0.5` and `1.0`."
required: false
type: float
default: "`0.5` for Celsius and `1.0` for Fahrenheit."
floor_temperature:
description: Some thermostats round all temperatures down to the lower value according to their precision. Default behaviour for Home Assistant is to round temperatures to the nearest value. Set this to `True` to override Home Assistant and round to the lower value according to the configured `precision`.
required: false
type: boolean
{% endconfiguration %}
# {% linkable_title Example %}
A full configuration example with the OpenTherm Gateway connected to a remote host running `ser2net` looks like the one below.
```yaml
# Full example configuration.yaml entry
climate:
- platform: opentherm_gw
device: socket://otgw.example.org:2345
name: Thermostat
precision: 0.5
floor_temperature: True
```

Binary file not shown.

After