The `sma` sensor will poll a [SMA](http://www.sma-solar.com/) [(US)](http://www.sma-america.com/) solar inverter and present the values as sensors (or attributes of sensors) in Home Assistant.
This sensor uses the web interface and in order to use it you have to be able to connect to the solar inverter from your favorite web browser.
This sensor uses the web interface and to use it, you have to be able to connect to the solar inverter from your favorite web browser.
## Configuration
To enable this sensor, add the following lines to your `configuration.yaml` file:
```yaml
# Example configuration.yaml entry
# Example configuration.yaml entry (http)
sensor:
- platform: sma
host: IP_ADDRESS_OF_DEVICE
password: YOUR_SMA_PASSWORD
sensors:
current_consumption: [total_consumption]
pv_power:
total_yield:
- current_consumption
- total_consumption
- pv_power
- total_yield
# Example configuration.yaml entry (https)
sensor:
- platform: sma
host: IP_ADDRESS_OF_DEVICE
ssl: true
verify_ssl: false
password: YOUR_SMA_PASSWORD
sensors:
- current_consumption
- total_consumption
- pv_power
- total_yield
```
{% configuration %}
@ -55,50 +69,10 @@ group:
default: user
type: string
sensors:
description: A list of sensors that will be added. The value of the list can include a list of sensor names that will be used as attributes.
description: A list of sensors that will be added. Refer to the table in the Sensors section below. If not specified all the sensors in the library will be added.
required: false
default: All sensors
type: list
keys:
pv_power:
description: Current power generated by the inverter (W).
pv_gen_meter:
description: Total kWh generated to date (kWh)
total_yield:
description: Total power yield from solar installation (kWh).
daily_yield:
description: The yield for today (Wh)
current_consumption:
description: Power that you are currently drawing, depending on your installation it can be a combination of the inverter and the grid (W).
total_consumption:
description: Total power consumption (kWh).
grid_power_supplied:
description: Power supplied (W)
grid_power_absorbed:
description: Power absorbed (W)
grid_total_yield:
description: Total power fom the grid (kWh)
grid_total_absorbed:
description: Total power supplied to the grid
grid_power:
description: Power supplied by the grid (W)
frequency:
description: Grid frequency (W)
voltage_l1:
description: Voltage for phase 1 (V)
voltage_l2:
description: Voltage for phase 2 (V)
voltage_l2:
description: Voltage for phase 3 (V)
status:
description: Status of the solar plant.
your-custom-sensor:
description: Any sensor name defined in the `custom:` section
custom:
description: A dictionary of custom sensor key values and units.
required: false
@ -117,16 +91,36 @@ custom:
required: false
default: 1
type: float
path:
description: A custom JMESpath to extract the sensor value (typically not required, advanced use only).
required: false
type: string
{% endconfiguration %}
You can create composite sensors, where the sub-sensors will be attributes of the main sensor. E.g.,
## Sensors
```yaml
sensors:
- current_power: [total_power, total_consumption]
```
Sensors available in the library:
The SMA WebConnect module supports a wide variety of sensors, and not all these have been mapped to standard sensors. Custom sensors can be defined by using the `custom` section of the configuration. You will need: A sensor name (no spaces), the SMA sensor key and the unit
| name | Unit | Description |
|--------------|------|:-------------------------------------------|
| pv_power | W | Current power generated by the inverter. |
| pv_gen_meter | kWh | Total kWh generated to date. |
| total_yield | kWh | Total power yield from a solar installation. |
| daily_yield | Wh | The solar plant's yield for today. !
| current_consumption | W | Power that you are currently drawing, depending on your installation it can be a combination of the inverter and the grid. |
| total_consumption | kWh | Total power consumption. |
| grid_power_supplied | W | Power supplied. |
| grid_power_absorbed | W | Power absorbed. |
| grid_total_yield | kWh | Total power from the grid. |
| grid_total_absorbed | Wh | Total power supplied to the grid
| grid_power | W | Power supplied by the grid. |
| frequency | Hz | Grid frequency. |
| voltage_l1 | V | Voltage for phase 1. |
| voltage_l2 | V | Voltage for phase 2. |
| voltage_l2 | V | Voltage for phase 3. |
| status | | Status of the solar plant. |
The SMA WebConnect module supports a wide variety of sensors, and not all these have been mapped in the `pysma` library. Custom sensors can be defined by using the `custom` section of the configuration. You will need: A sensor name (no spaces), the SMA sensor key and the unit.
Example: