@ -9,19 +9,35 @@ ha_domain: enphase_envoy
ha_zeroconf: true
ha_config_flow: true
ha_codeowners:
- '@gtdiehl'
- '@bdraco'
- '@cgarwood'
- '@dgomes'
- '@joostlek'
ha_platforms:
- binary_sensor
- diagnostics
- sensor
ha_integration_type: integration
---
A sensor platform for the [Enphase Envoy](https://enphase.com/en-us/products-and-services/envoy-and-combiner) solar energy gateway. Works with older models that only have production metrics (ie. Envoy-C) and newer models that offer both production and consumption metrics (ie. Envoy-S).
An integration for the [Enphase Envoy](https://enphase.com/en-us/products-and-services/envoy-and-combiner) solar energy gateway. This integration works with older models that only have production metrics (ie. Envoy-C) and newer models that offer both production and consumption metrics (ie. Envoy-S). Firmware version 3.9 or newer is required.
{% include integrations/config_flow.md %}
### Obtaining the password
## Capabilities
For newer models, the username `envoy` without a password will grant access to the device. For older models, the password for the `installer` user can be obtained with this: [tool](https://thecomputerperson.wordpress.com/2016/08/28/reverse-engineering-the-enphase-installer-toolkit/).
This integration will offer various sensors depending on the configuration of your Enphase system. Sensors are available for the following:
In some cases, you need to use the username `envoy` with the last 6 digits of the unit's serial number as password. See [the enphase documentation](https://support.enphase.com/s/article/What-is-the-Username-and-Password-for-the-Administration-page-of-the-Envoy-local-interface) for more details on other units.
- Current energy production & consumption
- Historical energy production & consumption
- Power production per-inverter
_Consumption sensors require your Envoy to be properly configured with consumption CT sensors installed._
For Enphase Ensemble systems with the Enpower/IQ System Controller and Encharge/IQ Batteries installed, additional sensors are available for battery status and usage.
## Envoy authentication requirements
For newer models running firmware 7 and greater, you will need your Enlighten cloud username and password. The integration will use these credentials to obtain an Envoy access token from the Enlighten cloud.
For models running firmware 5 and older, use `installer` for the username. No password is required. The integration will automatically detect the `installer` password.