@ -10,6 +10,7 @@ footer: true
logo: ecobee.png logo: ecobee.png
ha_category: Climate ha_category: Climate
ha_release: 0.9 ha_release: 0.9
ha_iot_class: "Cloud Push"
--- ---
To get your Ecobee thermostats working with Home Assistant, follow the instructions for the general [Ecobee component](/components/ecobee/). To get your Ecobee thermostats working with Home Assistant, follow the instructions for the general [Ecobee component](/components/ecobee/).

View File

@ -57,8 +57,15 @@ to the start function of /etc/init.d/hass-daemon.
```yaml ```yaml
# Example configuration.yaml entry # Example configuration.yaml entry
climate: climate:
platform: eq3btsmart - platform: eq3btsmart
devices: devices:
room1: room1:
mac: '00:11:22:33:44:55' mac: '00:11:22:33:44:55'
``` ```
Configuration variables:
- **devices** array (*Required*): List of thermostats.
- **[device-name]** (*Required*): The name to use for the thermostat.
- **mac** (*Required*): MAC address of the thermostat.

View File

@ -9,6 +9,7 @@ sharing: true
footer: true footer: true
logo: heat-control.png logo: heat-control.png
ha_category: Climate ha_category: Climate
ha_release: pre 0.7
--- ---
@ -17,29 +18,35 @@ The `generic_thermostat` climate platform is a thermostat implemented in Home As
```yaml ```yaml
# Example configuration.yaml entry # Example configuration.yaml entry
climate: climate:
platform: generic_thermostat - platform: generic_thermostat
name: Study name: Study
heater: switch.study_heater heater: switch.study_heater
target_sensor: sensor.study_temperature target_sensor: sensor.study_temperature
min_temp: 15
max_temp: 21
target_temp: 15
min_cycle_duration:
# At least one of these must be specified:
days: 2
hours: 1
minutes: 10
seconds: 5
milliseconds: 20
``` ```
Configuration variables: Configuration variables:
- **name** (*Required*): Name of thermostat - **name** (*Required*): Name of thermostat
- **heater** (*Required*: `entity_id` for heater switch, must be a toggle device. - **heater** (*Required*): `entity_id` for heater switch, must be a toggle device.
- **target_sensor** (*Required*): `entity_id` for a temperature sensor, target_sensor.state must be temperature. - **target_sensor** (*Required*): `entity_id` for a temperature sensor, target_sensor.state must be temperature.
- **min_temp** (*Optional*): Set minimum set point available (default: 7) - **min_temp** (*Optional*): Set minimum set point available (default: 7)
- **max_temp** (*Optional*): Set maximum set point available (default: 35) - **max_temp** (*Optional*): Set maximum set point available (default: 35)
- **target_temp** (*Optional*): Set intital target temperature. Failure to set this variable will result in target temperature being set to null on startup. - **target_temp** (*Optional*): Set intital target temperature. Failure to set this variable will result in target temperature being set to null on startup.
- **ac_mode** (*Optional*): Set the switch specified in the *heater* option to be treated as a cooling device instead of a heating device. - **ac_mode** (*Optional*): Set the switch specified in the *heater* option to be treated as a cooling device instead of a heating device.
- **min_cycle_duration** (*Optional*): Set a minimum amount of time that the switch specified in the *heater* option must be in it's current state prior to being switched either off or on. - **min_cycle_duration** (*Optional*): Set a minimum amount of time that the switch specified in the *heater* option must be in it's current state prior to being switched either off or on.
A full configuration example looks like the one below. `min_cycle_duration` must contains at least one of the following entries: `days:`, `hours:`, `minutes:`, `seconds:` or `milliseconds:`.
```yaml
# Full example configuration.yaml entry
climate:
- platform: generic_thermostat
name: Study
heater: switch.study_heater
target_sensor: sensor.study_temperature
min_temp: 15
max_temp: 21
target_temp: 17
min_cycle_duration:
seconds: 5
```

View File

@ -20,8 +20,6 @@ To set it up, add the following information to your `configuration.yaml` file:
climate: climate:
platform: honeywell platform: honeywell
username: YOUR_USERNAME username: YOUR_USERNAME
password: YOUR_PASSWORD
region: REGION
``` ```
Configuration variables: Configuration variables:

View File

@ -24,15 +24,14 @@ To use your KNX thermostats in your installation, add the following to your `con
# Example configuration.yaml entry # Example configuration.yaml entry
climate: climate:
- platform: knx - platform: knx
name: KNX Thermostat
address : KNX_ADDRESS address : KNX_ADDRESS
temperature_address: 0/1/1 temperature_address: 0/1/1
setpoint_address: 0/1/0 setpoint_address: 0/1/0
``` ```
- **name** (*Optional*): A name for this devices used within Home assistant
- **address** (*Required*): The KNX group address that is used to turn on/off this actuator channel - **address** (*Required*): The KNX group address that is used to turn on/off this actuator channel
- **temperature_address** (*Required*): The group address that is used to communicate the current temperature. Data format must be datapoint type 9.001 DPT_Value_Temp (2-Octet float value), check [details](http://www.knx.org/fileadmin/template/documents/downloads_support_menu/KNX_tutor_seminar_page/Advanced_documentation/05_Interworking_E1209.pdf). - **temperature_address** (*Required*): The group address that is used to communicate the current temperature. Data format must be datapoint type 9.001 DPT_Value_Temp (2-Octet float value), check [details](http://www.knx.org/fileadmin/template/documents/downloads_support_menu/KNX_tutor_seminar_page/Advanced_documentation/05_Interworking_E1209.pdf).
- **setpoint_address** (*Required*): The group address that is used to set/read the target temperature. Data format must be datapoint type 9.001 DPT_Value_Temp (2-Octet float value). Make sure, you set the read-flag for the thermostat to allow Home Assistant to read the target temperature. - **setpoint_address** (*Required*): The group address that is used to set/read the target temperature. Data format must be datapoint type 9.001 DPT_Value_Temp (2-Octet float value). Make sure, you set the read-flag for the thermostat to allow Home Assistant to read the target temperature.
- **name** (*Optional*): A name for this devices used within Home Assistant
With the current version of the module, no advanced KNX thermostat functionalities (e.g. HVAC mode) are supported. With the current version of the module, no advanced KNX thermostat functionalities (e.g. HVAC mode) are supported.

View File

@ -24,12 +24,9 @@ The underlaying library supports:
To set it up, add the following information to your `configuration.yaml` file: To set it up, add the following information to your `configuration.yaml` file:
```yaml ```yaml
# Example configuration.yaml entry
climate: climate:
platform: radiotherm platform: radiotherm
host:
- 192.168.99.137
- 192.168.99.202
hold_temp: True
``` ```
Configuration variables: Configuration variables:
@ -39,3 +36,12 @@ Configuration variables:
Temperature settings from Home Assistant will be sent to thermostat and then hold at that temperature. Set to `False` if you set a thermostat schedule on the thermostat itself and just want Home Assistant to send temporary temperature changes. Temperature settings from Home Assistant will be sent to thermostat and then hold at that temperature. Set to `False` if you set a thermostat schedule on the thermostat itself and just want Home Assistant to send temporary temperature changes.
Multiple thermostats could be assigned by using `host:` if auto-detetion is not used.
```yaml
climate:
platform: radiotherm
host:
- 192.168.99.137
- 192.168.99.202
```