Merge branch 'current' into next

This commit is contained in:
Franck Nijhof 2019-07-18 19:22:22 +02:00
commit 6a2284729a
No known key found for this signature in database
GPG Key ID: D62583BA8AB11CA3
5 changed files with 20 additions and 16 deletions

View File

@ -17,7 +17,7 @@ The `arcam_fmj` integration allows you to control [Arcam FMJ Receveivers](https:
Supported devices:
- AVR 380
- AVR 380
- AVR 450
- AVR 750
- Likely other AVRs
@ -49,15 +49,18 @@ zone:
type: map
keys:
ZONE_INDEX:
name:
description: Name of zone
required: false
type: string
default: Arcam FMJ - ZONE_INDEX
turn_on:
description: Service to use when turning on device when no connection is established
required: false
type: action
description: Zone index number.
type: map
keys:
name:
description: Name of zone
required: false
type: string
default: Arcam FMJ - ZONE_INDEX
turn_on:
description: Service to use when turning on device when no connection is established
required: false
type: action
{% endconfiguration %}
```yaml

View File

@ -80,7 +80,7 @@ Set target temperature of climate device
| `temperature` | no | New target temperature for hvac
| `target_temp_high` | yes | New target high temperature for hvac
| `target_temp_low` | yes | New target low temperature for hvac
| `operation_mode` | yes | Operation mode to set temperature to. This defaults to current_operation mode if not set, or set incorrectly.
| `hvac_mode` | yes | HVAC mode to set temperature to. This defaults to current HVAC mode if not set, or set incorrectly.
#### Automation example
@ -94,7 +94,7 @@ automation:
data:
entity_id: climate.kitchen
temperature: 24
operation_mode: Heat
hvac_mode: heat
```
### Service `climate.set_humidity`
@ -163,7 +163,7 @@ automation:
- service: climate.set_hvac_mode
data:
entity_id: climate.kitchen
operation_mode: heat
hvac_mode: heat
```
### Service `climate.set_swing_mode`

View File

@ -200,6 +200,7 @@ hold_state_template:
hold_modes:
description: A list of available hold modes.
required: false
type: list
aux_command_topic:
description: The MQTT topic to publish commands to switch auxiliary heat.
required: false
@ -281,7 +282,7 @@ climate:
name: Study
modes:
- "off"
- "on"
- "heat"
- "auto"
mode_command_topic: "study/ac/mode/set"
mode_state_topic: "study/ac/mode/state"

View File

@ -84,7 +84,7 @@ vacuum:
fan_speeds:
description: List of fan speeds supported by the vacuum.
required: false
type: string list
type: [string, list]
{% endconfiguration %}
## {% linkable_title Examples %}

View File

@ -50,7 +50,7 @@ longitude:
radius:
description: The radius around your location to monitor; defaults to 25 km or mi (depending on the unit system defined in your `configuration.yaml`).
required: false
type: int
type: integer
window:
description: The amount of time before now for which strikes should be considered "active" and shown in the UI.
required: false