diff --git a/source/_integrations/greeneye_monitor.markdown b/source/_integrations/greeneye_monitor.markdown index c655ae01a76..43d26d0af41 100644 --- a/source/_integrations/greeneye_monitor.markdown +++ b/source/_integrations/greeneye_monitor.markdown @@ -34,6 +34,9 @@ greeneye_monitor: temperature_sensors: - number: 1 name: back_porch_temperature + voltage: + - number: 1 + name: house_volts ``` By default, GEM will send updates every 5 seconds. That's a lot of data, and the databases used by the [`recorder`](/integrations/recorder) integration for history don't do well with that much data, so it is recommended to configure the [`influxdb`](/integrations/influxdb) integration and exclude the GEM sensors from `recorder`. @@ -70,6 +73,18 @@ monitors: required: false type: boolean default: false + voltage: + description: Configuration for voltage sensor + required: false + keys: + number: + description: A channel number that exists in the GEM. There is only one voltage sensor on current models of the GEM. + required: true + type: integer + name: + description: The name that should be used for the voltage sensor in Home Assistant. + required: true + type: string temperature_sensors: description: Configuration for temperature sensors required: false