Update nuheat for new climate platform (#12341)
* Update nuheat for new climate platform * Update source/_integrations/nuheat.markdown Co-Authored-By: Franck Nijhof <git@frenck.dev> * Update source/_integrations/nuheat.markdown Co-Authored-By: Franck Nijhof <git@frenck.dev> * Update source/_integrations/nuheat.markdown Co-Authored-By: Franck Nijhof <git@frenck.dev> Co-authored-by: Franck Nijhof <git@frenck.dev>
This commit is contained in:
parent
8ef56f04cf
commit
6f40c966c3
@ -136,28 +136,19 @@ Returns the maximum supported temperature by the thermostat
|
||||
|
||||
The following services are provided by the NuHeat Thermostat: `set_temperature`, `set_hvac_mode`, `set_preset_mode`, `resume_program`.
|
||||
|
||||
The services `fan_min_on_time`, `set_aux_heat`, `set_away_mode`, `set_humidity`, `set_fan_mode`, and `set_swing_mode` offered by the [Climate component](/integrations/climate/) are not implemented for this thermostat.
|
||||
### Service `climate.set_hvac_mode` ([Climate integration](/integrations/climate/))
|
||||
|
||||
### Service `set_temperature`
|
||||
NuHeat Thermostats do not have an off concept. Setting the temperature to `min_temp` and changing the mode to `heat` will cause the device to enter a `Permanent Hold` preset and will stop the thermostat from turning on unless you happen to live in a freezing climate.
|
||||
|
||||
Puts the thermostat into an indefinite hold at the given temperature.
|
||||
### Service `climate.set_temperature` ([Climate integration](/integrations/climate/))
|
||||
|
||||
| Service data attribute | Optional | Description |
|
||||
| ---------------------- | -------- | ----------- |
|
||||
| `entity_id` | yes | String or list of strings that point at `entity_id`'s of climate devices to control. Use `entity_id: all` to target all.
|
||||
| `temperature` | no | Desired target temperature (when not in auto mode)
|
||||
If the thermostat is in auto mode, it puts the thermostat into a temporary hold at the given temperature.
|
||||
|
||||
Only the target temperatures relevant for the current operation mode need to
|
||||
be provided.
|
||||
If the thermostat is in heat mode, it puts the thermostat into a permanent hold at the given temperature.
|
||||
|
||||
### Service `set_preset_mode`
|
||||
### Service `climate.set_preset_mode` ([Climate integration](/integrations/climate/))
|
||||
|
||||
Sets the thermostat's preset mode. Without a preset mode set it run the thermostat's programmed schedule, "temperature" (to indefinitely hold the thermostat's current target temperature), or "temporary_temperature" (to hold the thermostat's current target temperature until the thermostat's next scheduled event).
|
||||
|
||||
| Service data attribute | Optional | Description |
|
||||
| ---------------------- | -------- | ----------- |
|
||||
| `entity_id` | yes | String or list of strings that point at `entity_id`'s of climate devices to control. Use `entity_id: all` to target all.
|
||||
| `hold_mode` | no | New value of hold mode.
|
||||
The following presets are available: `Run Schedule`, `Temporary Hold`, `Permanent Hold`.
|
||||
|
||||
### Service `nuheat.resume_program`
|
||||
|
||||
|
Loading…