Add climate.modbus module documentation (#4593)
* Added climate.modbus module documentation
* Update climate.modbus.markdown
Updated IOT class Local Push to Local Polling.
* Reviewed comments for changes
Added configuration tags, removed optional configuration values, and set the correct release version.
* Fixed formatting with the configuration settings
* ⬆️ ha_release -> 0.68
This commit is contained in:
parent
e607d1bf39
commit
70af38b086
70
source/_components/climate.modbus.markdown
Normal file
70
source/_components/climate.modbus.markdown
Normal file
@ -0,0 +1,70 @@
|
||||
---
|
||||
layout: page
|
||||
title: "Modbus"
|
||||
description: "Instructions how to integrate a Modbus thermostat within Home Assistant."
|
||||
date: 2018-01-29 9:35
|
||||
sidebar: true
|
||||
comments: false
|
||||
sharing: true
|
||||
footer: true
|
||||
logo: modbus.png
|
||||
ha_category: Thermostat
|
||||
ha_release: 0.68
|
||||
ha_iot_class: "Local Polling"
|
||||
---
|
||||
|
||||
|
||||
The `modbus` thermostat allows you to use a sensor value (current temperature)
|
||||
and target value (target temperature) from [Modbus](http://www.modbus.org/)
|
||||
registers.
|
||||
|
||||
To use your Modbus thermostat in your installation, add the following to your `configuration.yaml` file:
|
||||
|
||||
```yaml
|
||||
climate:
|
||||
- platform: modbus
|
||||
name: Watlow F4T
|
||||
slave: 1
|
||||
target_temp_register: 2782
|
||||
current_temp_register: 27586
|
||||
|
||||
```
|
||||
|
||||
{% configuration %}
|
||||
name:
|
||||
description: Name of the device
|
||||
required: true
|
||||
type: string
|
||||
slave:
|
||||
description: The number of the slave (Optional for tcp and upd Modbus, use 1).
|
||||
required: true
|
||||
type: int
|
||||
target_temp_register:
|
||||
description: Register number for target temperature (Setpoint).
|
||||
required: true
|
||||
type: int
|
||||
current_temp_register:
|
||||
description: Register number for current temperature (Process value).
|
||||
required: true
|
||||
type: int
|
||||
data_type:
|
||||
description: Response representation (int, uint, float, custom). If float selected, value will converted to IEEE 754 floating point format.
|
||||
Default float.
|
||||
required: false
|
||||
type: string
|
||||
count:
|
||||
description: Number of registers to read.
|
||||
required: false
|
||||
type: int
|
||||
precision:
|
||||
description: Number of valid decimals, default 0.
|
||||
required: false
|
||||
type: int
|
||||
{% endconfiguration %}
|
||||
|
||||
|
||||
### {% linkable_title Services %}
|
||||
|
||||
| Service | Description |
|
||||
| ------- | ----------- |
|
||||
| set_temperature | Set Temperature. Requires `value` to be passed in, which is the desired target temperature. `value` should be in the same type as `data_type` |
|