@ -18,20 +18,42 @@ ha_codeowners:
|
|||||||
- '@SonnenladenGmbH'
|
- '@SonnenladenGmbH'
|
||||||
---
|
---
|
||||||
|
|
||||||
The **APsystems** {% term integration %} allows you to read the data from your [APsystems EZ1](https://emea.apsystems.com/diy/ez1/) microinverter. It also allows you to set the output limit to any number between 30 and 800 watts.
|
The **APsystems** {% term integration %} allows you to read the data from your [APsystems EZ1](https://emea.apsystems.com/diy/ez1/) microinverter. It also allows you to set the output limit to anything above 30 watts.
|
||||||
The following data is provided by the integration:
|
|
||||||
|
## Sensors
|
||||||
|
|
||||||
|
### Numerical sensors
|
||||||
|
|
||||||
|
| Sensor ID | Unit | Description
|
||||||
|
|---|---| ---|
|
||||||
|
| total_power | W | Total current output of the inverter
|
||||||
|
| lifetime_production_p1 | kWh | Lifetime production of first input
|
||||||
|
| lifetime_production_p2 | kWh | Lifetime production of second input
|
||||||
|
| lifetime_production | kWh | Lifetime production of both inputs combined
|
||||||
|
| total_power_p1 | W | Current input on first input
|
||||||
|
| total_power_p2 | W | Current input on second input
|
||||||
|
| today_production | kWh | Today's production of both inputs combined
|
||||||
|
| today_production_p1 | kWh | Today's production of first input
|
||||||
|
| today_production_p2 | kWh | Today's production of second input
|
||||||
|
|
||||||
|
### Binary sensors
|
||||||
|
|
||||||
|
| Sensor ID | Description
|
||||||
|
|---|---|
|
||||||
|
| off_grid_status | On when the inverter is not connected to the power grid
|
||||||
|
| dc_1_short_circuit_error_status | Short circuit detected on first input
|
||||||
|
| dc_2_short_circuit_error_status | Short circuit detected on second input
|
||||||
|
| output_fault_status | Output because of any error deactivated
|
||||||
|
|
||||||
|
## Settings
|
||||||
|
|
||||||
|
| Setting ID | Type | Description
|
||||||
|
|---|---|---|
|
||||||
|
| inverter_status | switch | Enables or disables the inverter's output
|
||||||
|
| output_limit | number | Sets the max output of the inverter
|
||||||
|
|
||||||
- Lifetime production (Per input and in total)
|
|
||||||
- Current production (Per input and in total)
|
|
||||||
- Today's production (Per input and in total)
|
|
||||||
- Short circuit error status (per input)
|
|
||||||
- Off grid status
|
|
||||||
- Output status
|
|
||||||
|
|
||||||
The following data can be set by the integration:
|
|
||||||
|
|
||||||
- Maximal output in watts
|
|
||||||
- Inverter status (on or off)
|
|
||||||
|
|
||||||
## Prerequisites
|