NUT sensor enhancements (#5411)
This commit is contained in:
parent
e49e5917e2
commit
82425ff96b
@ -28,56 +28,83 @@ sensor:
|
||||
- battery.runtime
|
||||
```
|
||||
|
||||
Configuration variables:
|
||||
|
||||
- **name** (*Optional*): Name prefix for defined sensors. Defaults to 'NUT UPS'.
|
||||
- **host** (*Optional*): The host name or address of the device that is running NUT. Defaults to localhost.
|
||||
- **port** (*Optional*): The port number. Defaults to 3493.
|
||||
- **alias** (*Optional*): Name of the ups on the NUT server. Will default to the first UPS name listed.
|
||||
- **username** (*Optional*): Username to login to the NUT server. Default is none.
|
||||
- **password** (*Optional*): Password to login to the NUT server. Default is none.
|
||||
- **resources** array (*Required*): Contains all entries to display.
|
||||
{% configuration %}
|
||||
name:
|
||||
description: Name prefix for defined sensors.
|
||||
required: false
|
||||
default: 'NUT UPS'
|
||||
type: string
|
||||
host:
|
||||
description: The host name or IP address of the device that is running NUT.
|
||||
required: false
|
||||
default: localhost
|
||||
type: string
|
||||
port:
|
||||
description: The port number.
|
||||
required: false
|
||||
default: 3493
|
||||
type: int
|
||||
alias:
|
||||
description: Name of the ups on the NUT server.
|
||||
required: false
|
||||
default: Will default to the first UPS name listed.
|
||||
type: string
|
||||
username:
|
||||
description: Username to login to the NUT server.
|
||||
required: false
|
||||
default: none
|
||||
type: string
|
||||
password:
|
||||
description: Password to login to the NUT server.
|
||||
required: false
|
||||
default: none
|
||||
type: string
|
||||
resources:
|
||||
description: Contains all entries to display.
|
||||
required: true
|
||||
type: list
|
||||
{% endconfiguration %}
|
||||
|
||||
### {% linkable_title Example %}
|
||||
|
||||
Given the following example output from NUT (Your variables may differ):
|
||||
Given the following example output from NUT (your variables may differ):
|
||||
|
||||
```yaml
|
||||
'ups.timer.reboot': '0',
|
||||
'battery.voltage': '27.0',
|
||||
'ups.firmware.aux': 'L3 -P ',
|
||||
'ups.mfr': 'American Power Conversion',
|
||||
'battery.runtime.low': '120',
|
||||
'ups.delay.shutdown': '20',
|
||||
'ups.load': '19',
|
||||
'ups.realpower.nominal': '600',
|
||||
'battery.charge.warning': '50',
|
||||
'battery.charge.low': '10',
|
||||
'ups.vendorid': '051d',
|
||||
'ups.timer.shutdown': '-1',
|
||||
'ups.test.result': 'No test initiated',
|
||||
'ups.firmware': '868.L3 -P.D',
|
||||
'battery.mfr.date': '2015/05/08',
|
||||
'ups.serial': '3B1519X19994 ',
|
||||
'ups.productid': '0002',
|
||||
'battery.runtime': '2552',
|
||||
'battery.date': '2001/09/25',
|
||||
'battery.voltage.nominal': '24.0',
|
||||
'battery.type': 'PbAc',
|
||||
'ups.mfr.date': '2015/05/08',
|
||||
'ups.status': 'OL',
|
||||
'ups.model': 'Back-UPS RS1000G',
|
||||
'ups.beeper.status': 'disabled',
|
||||
'battery.charge': '100',
|
||||
'input.sensitivity': 'medium',
|
||||
'ups.timer.reboot': '0'
|
||||
'battery.voltage': '27.0'
|
||||
'ups.firmware.aux': 'L3 -P '
|
||||
'ups.mfr': 'American Power Conversion'
|
||||
'battery.runtime.low': '120'
|
||||
'ups.delay.shutdown': '20'
|
||||
'ups.load': '19'
|
||||
'ups.realpower.nominal': '600'
|
||||
'battery.charge.warning': '50'
|
||||
'battery.charge.low': '10'
|
||||
'ups.vendorid': '051d'
|
||||
'ups.timer.shutdown': '-1'
|
||||
'ups.test.result': 'No test initiated'
|
||||
'ups.firmware': '868.L3 -P.D'
|
||||
'battery.mfr.date': '2015/05/08'
|
||||
'ups.serial': '3B1519X19994 '
|
||||
'ups.productid': '0002'
|
||||
'battery.runtime': '2552'
|
||||
'battery.date': '2001/09/25'
|
||||
'battery.voltage.nominal': '24.0'
|
||||
'battery.type': 'PbAc'
|
||||
'ups.mfr.date': '2015/05/08'
|
||||
'ups.status': 'OL'
|
||||
'ups.model': 'Back-UPS RS1000G'
|
||||
'ups.beeper.status': 'disabled'
|
||||
'battery.charge': '100'
|
||||
'input.sensitivity': 'medium'
|
||||
'input.transfer.low': '88'
|
||||
'input.transfer.high': '147',
|
||||
'input.voltage': '121.0',
|
||||
'input.voltage.nominal': '120',
|
||||
'input.transfer.reason': 'input voltage out of range',
|
||||
'input.transfer.high': '147'
|
||||
'input.voltage': '121.0'
|
||||
'input.voltage.nominal': '120'
|
||||
'input.transfer.reason': 'input voltage out of range'
|
||||
```
|
||||
|
||||
Use the values from the left hand column. Support is included for most values with 'ups', 'battery', and 'input' prefixes.
|
||||
Use the values from the left hand column. Support is included for most values with 'ups', 'battery', and 'input' prefixes.
|
||||
|
||||
```yaml
|
||||
sensor:
|
||||
@ -94,3 +121,14 @@ sensor:
|
||||
- input.voltage
|
||||
- battery.runtime
|
||||
```
|
||||
|
||||
### {% linkable_title UPS Status - human-readable version %}
|
||||
|
||||
An additional virtual sensor type `ups.status.display` is available translating the UPS status value retrieved from `ups.status` into a human-readable version.
|
||||
|
||||
```yaml
|
||||
sensor:
|
||||
- platform: nut
|
||||
resources:
|
||||
- ups.status.display
|
||||
```
|
||||
|
Loading…