honeywell - Fix issue 18932 & clean up the mess (#9587)
* clean up docs * less notes * ad first warning back in * ✏️ Tweak * ✏️ Tweak
This commit is contained in:
parent
d4fcdc3860
commit
86c0ec830f
@ -16,54 +16,67 @@ redirect_from:
|
||||
- /components/climate.honeywell/
|
||||
---
|
||||
|
||||
The `honeywell` climate platform lets you control Honeywell TCC (Total Connect Comfort) climate systems from Home Assistant. It does not integrate with Honeywell TCC alarm systems.
|
||||
|
||||
The `honeywell` climate platform let you control Honeywell Connected thermostats from Home Assistant.
|
||||
<p class='note'>
|
||||
There is some potential confusion over this integration because it is currently implemented as a combination of two _distinct_ climate systems, one being US-based, the other is EU-based.
|
||||
|
||||
To set it up, add the following information to your `configuration.yaml` file:
|
||||
These two regions are _not_ interchangeable, so you must be clear which applies to your climate system.
|
||||
</p>
|
||||
|
||||
## {% linkable_title US-based Systems %}
|
||||
|
||||
These systems are based in North America, and temperatures are usually in Fahrenheit. They would likely be HVAC systems. They always use the [somecomfort](https://github.com/kk7ds/somecomfort) client library. In this integration, this is called the `us` region.
|
||||
|
||||
If your system is US-based, then you can access your system via [https://mytotalconnectcomfort.com/portal/](https://mytotalconnectcomfort.com/portal/) (note the `/portal/`).
|
||||
|
||||
## {% linkable_title EU-based Systems %}
|
||||
|
||||
These systems are based in Europe (including the UK & Ireland), and temperatures are usually in Celsius. They would likely be heating-only systems. They always use the [evohome-client](https://github.com/watchforstock/evohome-client) client library. In this integration, this is called the `eu` region.
|
||||
|
||||
If your system is US-based, then you can access it via [https://international.mytotalconnectcomfort.com/](https://international.mytotalconnectcomfort.com/) (note the `international`).
|
||||
|
||||
The `eu` region is soon to be deprecated, and ongoing support for such systems is available via the [evohome](/components/evohome/) integration.
|
||||
|
||||
## {% linkable_title Configuration %}
|
||||
|
||||
To set up this integration, first confirm your region, then add the following information to your **configuration.yaml** file (the below example is for US-based systems):
|
||||
|
||||
```yaml
|
||||
climate:
|
||||
- platform: honeywell
|
||||
username: YOUR_USERNAME
|
||||
password: YOUR_PASSWORD
|
||||
scan_interval: 600
|
||||
region: us
|
||||
```
|
||||
<p class='note'>
|
||||
Scan interval is expressed in seconds. Omitting or mis-configuring `scan_interval` may result in too-frequent polling and cause you to be rate-limited by Honeywell.
|
||||
</p>
|
||||
|
||||
{% configuration %}
|
||||
username:
|
||||
description: The username of an user with access.
|
||||
description: Email address of an account with access the TCC website for your region.
|
||||
required: true
|
||||
type: string
|
||||
password:
|
||||
description: The password for your given admin account.
|
||||
description: Password for the account.
|
||||
required: true
|
||||
type: string
|
||||
region:
|
||||
description: Region identifier (either 'eu' or 'us'). Use the `somecomfort` client library for `us`, and evohome-client for `eu`.
|
||||
description: Region identifier, either 'eu' or 'us'.
|
||||
required: false
|
||||
default: eu
|
||||
type: string
|
||||
scan_interval:
|
||||
description: Scan interval is expressed in seconds. Recommended value of 600 seconds. Omitting scan_interval may result in too-frequent polling and cause you to rate-limited by Honeywell.
|
||||
required: false
|
||||
default: 120
|
||||
type: integer
|
||||
away_temperature:
|
||||
description: "(*only for eu region*) Heating setpoint when away mode is on, in deg C."
|
||||
description: "(*only for the EU region*) Heating setpoint when away mode is on, in degrees Celsius."
|
||||
required: false
|
||||
default: 16.0
|
||||
type: float
|
||||
away_cool_temperature:
|
||||
description: "(*only for us region*) Cooling setpoint when away mode is on, in deg C."
|
||||
description: "(*only for the US region*) Cooling setpoint when away mode is on, in degrees Fahrenheit."
|
||||
required: false
|
||||
default: 30.0
|
||||
type: float
|
||||
default: 88
|
||||
type: integer
|
||||
away_heat_temperature:
|
||||
description: "(*only for us region*) Heating setpoint when away mode is on, in deg C."
|
||||
description: "(*only for the US region*) Heating setpoint when away mode is on, in degrees Fahrenheit."
|
||||
required: false
|
||||
default: 16.0
|
||||
type: float
|
||||
default: 61
|
||||
type: integer
|
||||