From 8bf76ff580a706326e55453d2bbcd460698b9f85 Mon Sep 17 00:00:00 2001 From: Marlon Date: Mon, 14 Apr 2025 15:30:04 +0200 Subject: [PATCH] Add note on flash endurance for APsystems integration (#38313) Co-authored-by: Franck Nijhof --- source/_integrations/apsystems.markdown | 3 +++ 1 file changed, 3 insertions(+) diff --git a/source/_integrations/apsystems.markdown b/source/_integrations/apsystems.markdown index 8c155974c8f..6aad8bc603b 100644 --- a/source/_integrations/apsystems.markdown +++ b/source/_integrations/apsystems.markdown @@ -53,6 +53,9 @@ The **APsystems** {% term integration %} allows you to read the data from your [ | output_limit | number | Sets the max output of the inverter +## Flash Endurance + +There has been a discussion about the inverter's lifetime being shortened when using the `output_limit` setting excessively. APsystems officially confirmed this to me while also acknowledging that newer hardware versions don't have this issue, while older ones should be updated at most every 300 seconds. Newer inverters have a serial number starting with `Ex701` and thus aren't at risk of flash wear when setting the `output_limit` more frequently than every 300 seconds. ## Prerequisites