@ -62,12 +62,12 @@ min_cycle_duration:
|
||||
required: false
|
||||
type: [time, integer]
|
||||
dry_tolerance:
|
||||
description: Set a minimum amount of difference between the humidity read by the sensor specified in the *target_sensor* option and the target humidity that must change prior to being switched on. For example, if the target humidity is 45 and the tolerance is 3 the humidifier will start when the sensor equals or goes below 42. It is advised to set this parameter equal or above your sensor precision. This parameter is only used on *target_sensor* changes and is ignored on initialization or manual operation.
|
||||
description: Set a minimum amount of difference between the humidity read by the sensor specified in the *target_sensor* option and the target humidity that must change prior to being switched on. For example, if the target humidity is 45 and the tolerance is 3 the humidifier will start when the sensor equals or goes below 42. It is advised to set this parameter equal or above your sensor precision. This parameter is only used on *target_sensor* changes and is ignored on initialization, on manual operation or `humidifier.turn_on` service.
|
||||
required: false
|
||||
default: 3
|
||||
type: float
|
||||
wet_tolerance:
|
||||
description: Set a minimum amount of difference between the humidity read by the sensor specified in the *target_sensor* option and the target humidity that must change prior to being switched off. For example, if the target humidity is 45 and the tolerance is 3 the humidifier will stop when the sensor equals or goes above 48. It is advised to set this parameter equal or above your sensor precision. This parameter is only used on *target_sensor* changes and is ignored on initialization or manual operation.
|
||||
description: Set a minimum amount of difference between the humidity read by the sensor specified in the *target_sensor* option and the target humidity that must change prior to being switched off. For example, if the target humidity is 45 and the tolerance is 3 the humidifier will stop when the sensor equals or goes above 48. It is advised to set this parameter equal or above your sensor precision. This parameter is only used on *target_sensor* changes and is ignored on initialization, on manual operation or `humidifier.turn_on` service.
|
||||
required: false
|
||||
default: 3
|
||||
type: float
|
||||
|