mirror of
https://github.com/home-assistant/home-assistant.io.git
synced 2025-07-22 16:56:50 +00:00
Multiple values per modbus hvac mode (#28719)
This commit is contained in:
parent
c8083a2dfe
commit
9bda57b88b
@ -613,7 +613,8 @@ climates:
|
|||||||
required: true
|
required: true
|
||||||
type: integer
|
type: integer
|
||||||
write_registers:
|
write_registers:
|
||||||
description: "Request type, use `write_registers` if true else `write_register`."
|
description: "Request type, use `write_registers` if true else `write_register`.
|
||||||
|
If more than one value is specified for a specific mode, only the first one is used for writing to the register."
|
||||||
required: false
|
required: false
|
||||||
type: boolean
|
type: boolean
|
||||||
default: false
|
default: false
|
||||||
@ -625,15 +626,15 @@ climates:
|
|||||||
state_off:
|
state_off:
|
||||||
description: "Value corresponding to HVAC Off mode."
|
description: "Value corresponding to HVAC Off mode."
|
||||||
required: false
|
required: false
|
||||||
type: integer
|
type: [integer, list]
|
||||||
state_heat:
|
state_heat:
|
||||||
description: "Value corresponding to HVAC Heat mode."
|
description: "Value corresponding to HVAC Heat mode."
|
||||||
required: false
|
required: false
|
||||||
type: integer
|
type: [integer, list]
|
||||||
state_cool:
|
state_cool:
|
||||||
description: "Value corresponding to HVAC Cool mode."
|
description: "Value corresponding to HVAC Cool mode."
|
||||||
required: false
|
required: false
|
||||||
type: integer
|
type: [integer, list]
|
||||||
state_auto:
|
state_auto:
|
||||||
description: "Value corresponding to HVAC Auto mode."
|
description: "Value corresponding to HVAC Auto mode."
|
||||||
required: false
|
required: false
|
||||||
@ -641,15 +642,15 @@ climates:
|
|||||||
state_dry:
|
state_dry:
|
||||||
description: "Value corresponding to HVAC Dry mode."
|
description: "Value corresponding to HVAC Dry mode."
|
||||||
required: false
|
required: false
|
||||||
type: integer
|
type: [integer, list]
|
||||||
state_fan_only:
|
state_fan_only:
|
||||||
description: "Value corresponding to HVAC Fan only mode."
|
description: "Value corresponding to HVAC Fan only mode."
|
||||||
required: false
|
required: false
|
||||||
type: integer
|
type: [integer, list]
|
||||||
state_heat_cool:
|
state_heat_cool:
|
||||||
description: "Value corresponding to HVAC Heat/Cool mode."
|
description: "Value corresponding to HVAC Heat/Cool mode."
|
||||||
required: false
|
required: false
|
||||||
type: integer
|
type: [integer, list]
|
||||||
hvac_onoff_register:
|
hvac_onoff_register:
|
||||||
description: "Address of On/Off state.
|
description: "Address of On/Off state.
|
||||||
When zero is read from this register, the HVAC state is set to Off, otherwise the `hvac_mode_register`
|
When zero is read from this register, the HVAC state is set to Off, otherwise the `hvac_mode_register`
|
||||||
|