Improve one-wire sensor (#3656)

* Improve one-wire sensor

* Minor changes
This commit is contained in:
Hugo Gresse 2017-10-17 21:11:42 +02:00 committed by Fabian Affolter
parent 4b3b28af41
commit 9da7eeddea
No known key found for this signature in database
GPG Key ID: DDF3D6F44AAB1336

View File

@ -25,22 +25,35 @@ Supported devices:
- [DS2406/TAI-8570](https://datasheets.maximintegrated.com/en/ds/DS2406.pdf) Temperature and pressure sensor made by AAG
- [DS2438/B1-R1-A](https://datasheets.maximintegrated.com/en/ds/DS2438.pdf) Temperature, pressure and humidity sensor by AAG
The 1-Wire bus can be connected directly to the IO pins of Raspberry Pi or using dedicated interface adapter (e.g [DS9490R](https://datasheets.maximintegrated.com/en/ds/DS9490-DS9490R.pdf)). When an interface adapter is used, sensors can be accessed on Linux hosts via [owfs 1-Wire file system](http://owfs.org/). When using an interface adapter and the owfs, the 'mount_dir' option must be configured to correspond a directory, where owfs device tree has been mounted. If you are using Raspberry Pi and IO pin connected bus setup, don't use the 'mount_dir' option.
The 1-Wire bus can be connected directly to the IO pins of Raspberry Pi or using dedicated interface adapter (e.g [DS9490R](https://datasheets.maximintegrated.com/en/ds/DS9490-DS9490R.pdf)).
#### Raspberry Pi setup
In order ot setup 1-Wire support on Raspberry Pi, you'll need to edit `/boot/config.txt` following [this documentation](https://www.waveshare.com/wiki/Raspberry_Pi_Tutorial_Series:_1-Wire_DS18B20_Sensor#Enable_1-Wire). Don't use the `mount_dir` option.
#### Interface adapter setup
When an interface adapter is used, sensors can be accessed on Linux hosts via [owfs 1-Wire file system](http://owfs.org/). When using an interface adapter and the owfs, the `mount_dir` option must be configured to correspond a directory, where owfs device tree has been mounted.
<p class='note warning'>
This component has been modified to work with devices with multiple sensors which will cause a discontinuity in recorded values. Existing devices will receive a new ID and therefore show up as new devices.
If you wish to maintain continuity it can be resolved in the database by renaming the old devices to the new names.
Connect to your database using the instructions from https://home-assistant.io/docs/backend/database/
Check the names of sensors:
Connect to your database using the instructions from [home-assistant.io/docs/backend/database/](https://home-assistant.io/docs/backend/database/). Check the names of sensors:
```sql
SELECT entity_id, COUNT(*) as count FROM states GROUP BY entity_id ORDER BY count DESC LIMIT 10;
```
Alter the names of sensors using the following examples:
```sql
UPDATE states SET entity_id='sensor.<sensor_name>_temperature' WHERE entity_id LIKE 'sensor.<sensor_name>%' AND attributes LIKE '%\u00b0C%';
UPDATE states SET entity_id='sensor.<sensor_name>_pressure' WHERE entity_id LIKE 'sensor.<sensor_name>%' AND attributes LIKE '%mb%';
UPDATE states SET entity_id='sensor.<sensor_name>_humidity' WHERE entity_id LIKE 'sensor.<sensor_name>%' AND attributes LIKE '%%%' ESCAPE '';
Remember to replace <sensor_name> with the actual name of the sensor as seen in the SELECT query.
```
Remember to replace `<sensor_name>` with the actual name of the sensor as seen in the `SELECT` query.
</p>
#### Home Assistant setup
To enable One wire sensors in your installation, add the following to your `configuration.yaml` file:
```yaml