mirror of
https://github.com/home-assistant/home-assistant.io.git
synced 2025-07-19 07:17:14 +00:00
Add documentation for new bosch alarm integration (#37458)
This commit is contained in:
parent
974b66e1a3
commit
9ea29620c3
65
source/_integrations/bosch_alarm.markdown
Normal file
65
source/_integrations/bosch_alarm.markdown
Normal file
@ -0,0 +1,65 @@
|
|||||||
|
---
|
||||||
|
title: Bosch Alarm
|
||||||
|
description: Integrate Bosch Alarms.
|
||||||
|
ha_category:
|
||||||
|
- Alarm
|
||||||
|
ha_release: 2025.4
|
||||||
|
ha_iot_class: Local Push
|
||||||
|
ha_config_flow: true
|
||||||
|
ha_codeowners:
|
||||||
|
- '@mag1024'
|
||||||
|
- '@sanjay900'
|
||||||
|
ha_domain: bosch_alarm
|
||||||
|
ha_platforms:
|
||||||
|
- alarm_control_panel
|
||||||
|
ha_integration_type: integration
|
||||||
|
---
|
||||||
|
|
||||||
|
The **Bosch Alarm Panel** {% term integration %} allows you to connect your [Bosch Alarm Panel](https://www.boschsecurity.com) to Home Assistant to control and monitor your Bosch Alarm Panel.
|
||||||
|
|
||||||
|
{% include integrations/config_flow.md %}
|
||||||
|
|
||||||
|
## Supported devices
|
||||||
|
|
||||||
|
- _Solution 2000/3000/4000_
|
||||||
|
- B Series: _B3512/B4512/B5512/B6512_
|
||||||
|
- G Series: _B8512G/B9512G_
|
||||||
|
- _AMAX 2100/3000/4000_
|
||||||
|
- _D7412GV4/D9412GV4_ [^1]
|
||||||
|
|
||||||
|
[^1]: Firmware 2.0+
|
||||||
|
|
||||||
|
## Provided entities
|
||||||
|
|
||||||
|
The following {% term entities %} are provided:
|
||||||
|
|
||||||
|
- [Alarm Control Panel](#alarm-control-panel)
|
||||||
|
|
||||||
|
### Alarm Control Panel
|
||||||
|
|
||||||
|
This integration adds an Alarm Control Panel device for each configured area, with the ability to issue arm/disarm commands.
|
||||||
|
This entity reports state (_disarmed_, _armed_away_, etc.).
|
||||||
|
|
||||||
|
## Authentication
|
||||||
|
|
||||||
|
The primary means of authentication for the _Mode 2_ API is the _Automation_ passcode. It needs to be at least 10 characters long, and it is different from the _User_ code -- a shorter numeric pin used to arm/disarm the panel.
|
||||||
|
The integration will prompt for the required passcodes, which depend on the panel type.
|
||||||
|
|
||||||
|
| Panel | Code |
|
||||||
|
| --- | --- |
|
||||||
|
| Solution | User [^2] |
|
||||||
|
| B Series | Automation |
|
||||||
|
| G Series | Automation |
|
||||||
|
| AMAX | Both |
|
||||||
|
|
||||||
|
[^2]: The user needs to have the "master code functions" authority if you wish to interact with history events.
|
||||||
|
|
||||||
|
{% important %}
|
||||||
|
Since the _Mode 2_ automation user has "superuser" privileges, it bypasses the regularly configured alarm pin: you will _not_ be prompted for a _User_ code when arming/disarming through the integration.
|
||||||
|
{% endimportant %}
|
||||||
|
|
||||||
|
## Removing the integration
|
||||||
|
|
||||||
|
This integration follows standard integration removal. No extra steps are required.
|
||||||
|
|
||||||
|
{% include integrations/remove_device_service.md %}
|