Add periodically resetting utility meter config option (#26306)
Co-authored-by: Franck Nijhof <frenck@frenck.nl>
This commit is contained in:
parent
f034cd8fdd
commit
9ffa429785
@ -55,6 +55,10 @@ Net consumption:
|
|||||||
Delta values:
|
Delta values:
|
||||||
description: >
|
description: >
|
||||||
Enable this if the source values are delta values since the last reading instead of absolute values. When this option is enabled, each new value received will be added as-is to the utility meter instead of adding the _difference_ between the new value and previous value.
|
Enable this if the source values are delta values since the last reading instead of absolute values. When this option is enabled, each new value received will be added as-is to the utility meter instead of adding the _difference_ between the new value and previous value.
|
||||||
|
Periodically resetting:
|
||||||
|
description: >
|
||||||
|
Enable this if the source sensor state is expected to reset to 0, for example, a smart plug that resets on boot.
|
||||||
|
When this option is disabled (for example, if the source sensor is a domestic utility meter that never resets during the device's lifetime), the _difference_ between the new value and the last valid value is added to the utility meter, which avoids the loss of a meter reading after the source sensor becomes available after being unavailable.
|
||||||
{% endconfiguration_basic %}
|
{% endconfiguration_basic %}
|
||||||
|
|
||||||
If the meter reset cycle and reset offsets are to limited for your use case,
|
If the meter reset cycle and reset offsets are to limited for your use case,
|
||||||
@ -117,6 +121,11 @@ tariffs:
|
|||||||
required: false
|
required: false
|
||||||
default: []
|
default: []
|
||||||
type: list
|
type: list
|
||||||
|
periodically_resetting:
|
||||||
|
description: Enable this if the source sensor state is expected to reset to 0, for example, a smart plug that resets on boot. When this option is disabled (for example, if the source sensor is a domestic utility meter that never resets during the device's lifetime), the _difference_ between the new value and the last valid value is added to the utility meter, which avoids the loss of a meter reading after the source sensor becomes available after being unavailable.
|
||||||
|
required: false
|
||||||
|
default: true
|
||||||
|
type: boolean
|
||||||
{% endconfiguration %}
|