@ -90,7 +90,7 @@ config_file:
|
||||
required: false
|
||||
type: string
|
||||
individual_address:
|
||||
description: The KNX individual address (IA) that shall be used for routing or if a tunnelling server doesn't assign an IA at connection.
|
||||
description: The KNX individual address (IA) that shall be used for routing or if a tunneling server doesn't assign an IA at connection.
|
||||
required: false
|
||||
type: string
|
||||
default: "15.15.250"
|
||||
@ -122,7 +122,7 @@ Under normal conditions no connection configuration should be needed. The integr
|
||||
|
||||
### Tunneling
|
||||
|
||||
If you want to connect to a sepcific tunnelling server or if the auto detection of the KNX/IP device does not work the IP or/and port of the tunneling device can be configurated.
|
||||
If you want to connect to a specific tunneling server or if the auto detection of the KNX/IP device does not work the IP or/and port of the tunneling device can be configurated.
|
||||
|
||||
```yaml
|
||||
knx:
|
||||
@ -178,10 +178,10 @@ event_filter:
|
||||
|
||||
Every telegram that matches the filter with its destination field will be announced on the event bus as a `knx_event` event containing data attributes
|
||||
|
||||
- `data` contains the raw payload data (eg. 1 or "[12, 55]").
|
||||
- `destination` the KNX group address the telegram is sent to as string (eg. "1/2/3).
|
||||
- `data` contains the raw payload data (e.g., 1 or "[12, 55]").
|
||||
- `destination` the KNX group address the telegram is sent to as string (e.g., "1/2/3).
|
||||
- `direction` the direction of the telegram as string ("Incoming" / "Outgoing"). Currently only incoming telegrams generate the event.
|
||||
- `source` the KNX indidividual address of the sender as string (eg. "1.2.3").
|
||||
- `source` the KNX individual address of the sender as string (e.g., "1.2.3").
|
||||
- `telegramtype` the APCI service of the telegram. "GroupValueWrite", "GroupValueRead" or "GroupValueResponse" generate a knx_event.
|
||||
|
||||
## Services
|
||||
@ -214,7 +214,7 @@ You can also use the `homeassistant.update_entity` service call to issue GroupVa
|
||||
|
||||
### Register Event
|
||||
|
||||
The `knx.event_register` service can be used to register (or unregister) group addresses to fire `knx_event` Events. Events for group addresses matching the `event_filter` attribute in `configuration.yaml` can not be unregistered. See [knx_event](#events)
|
||||
The `knx.event_register` service can be used to register (or unregister) group addresses to fire `knx_event` Events. Events for group addresses matching the `event_filter` attribute in `configuration.yaml` cannot be unregistered. See [knx_event](#events)
|
||||
|
||||
{% configuration %}
|
||||
address:
|
||||
@ -275,12 +275,12 @@ entity_id:
|
||||
required: false
|
||||
attribute:
|
||||
description: Attribute of the entity that shall be sent to the KNX bus. If not set (or `None`) the state will be sent.
|
||||
Eg. for a light the state is eigther "on" or "off". With `attribute` you can expose its "brightness".
|
||||
For example for a light the state is either "on" or "off". With `attribute` you can expose its "brightness".
|
||||
type: string
|
||||
required: false
|
||||
default:
|
||||
description: Default value to send to the bus if the state or attribute value is `None`.
|
||||
Eg. a light with state "off" has no brightness attribute so a default value of `0` could be used.
|
||||
For example a light with state "off" has no brightness attribute so a default value of `0` could be used.
|
||||
If not set (or `None`) no value would be sent to the bus and a GroupReadRequest to the address would return the last known value.
|
||||
type: [boolean, string, integer, float]
|
||||
default: None
|
||||
@ -384,7 +384,7 @@ name:
|
||||
required: false
|
||||
type: string
|
||||
counter:
|
||||
description: Set to 2 if your only want the action to be executed if the button was pressed twice. To 3 for three times button pressed.
|
||||
description: Set to 2 if you only want the action to be executed if the button was pressed twice. Set to 3 for three times button pressed.
|
||||
required: false
|
||||
type: integer
|
||||
default: 1
|
||||
@ -657,7 +657,7 @@ move_long_address:
|
||||
required: false
|
||||
type: string
|
||||
move_short_address:
|
||||
description: KNX group address for moving the cover short time up or down. *DPT 1*
|
||||
description: KNX group address for moving the cover short time up or down. Used by some covers also as the means to stop the cover, if no dedicated `stop_address` exists on the actuator. *DPT 1*
|
||||
required: false
|
||||
type: string
|
||||
stop_address:
|
||||
@ -691,7 +691,7 @@ travelling_time_up:
|
||||
default: 25
|
||||
type: integer
|
||||
invert_position:
|
||||
description: Set this to `true` if your actuator report fully closed as 0% in KNX.
|
||||
description: Set this to `true` if your actuator reports fully closed as 0% in KNX.
|
||||
required: false
|
||||
default: false
|
||||
type: boolean
|
||||
|