layout: page
|
||||
title: "OpenUV Binary Sensor"
|
||||
description: "Instructions on how to integrate OpenUV binary sensors within Home Assistant."
|
||||
date: 2018-07-31 22:01
|
||||
sidebar: true
|
||||
comments: false
|
||||
sharing: true
|
||||
footer: true
|
||||
logo: openuv.jpg
|
||||
ha_category: Binary Sensor
|
||||
ha_release: 0.76
|
||||
ha_iot_class: "Cloud Polling"
|
||||
---
|
||||
|
||||
The `openuv` binary sensor platform allows you to view binary sensor data from
|
||||
[OpenUV](http://openuv.io).
|
||||
|
||||
<p class='note'>
|
||||
You must have the [OpenUV component](/components/openuv/) configured to use
|
||||
this platform. After configuring that component, binary sensors will
|
||||
automatically appear.
|
||||
</p>
|
126
source/_components/openuv.markdown
Normal file
126
source/_components/openuv.markdown
Normal file
@ -0,0 +1,126 @@
|
||||
---
|
||||
layout: page
|
||||
title: "OpenUV"
|
||||
description: "Instructions on how to integrate OpenUV within Home Assistant."
|
||||
date: 2018-07-31 22:01
|
||||
sidebar: true
|
||||
comments: false
|
||||
sharing: true
|
||||
footer: true
|
||||
logo: openuv.jpg
|
||||
ha_category: Hub
|
||||
ha_release: 0.76
|
||||
ha_iot_class: "Cloud Polling"
|
||||
---
|
||||
|
||||
The `openuv` component displays UV and Ozone data from
|
||||
[openuv.io](http://openuv.io).
|
||||
|
||||
## {% linkable_title Generating an API Key %}
|
||||
|
||||
To generate an API key, [simply log in to the OpenUV website](https://www.openuv.io/auth/google).
|
||||
|
||||
<p class='note warning'>
|
||||
The "Limited" plan (which is what new users are given by default) is limited to
|
||||
500 API requests per day. In order to leave a buffer, the `openuv` component
|
||||
queries the API every 30 minutes by default. This value can be modifed (via the
|
||||
`scan_interval` key), but please note that over-running the API will require
|
||||
you to upgrade to a paid plan (and may disable your access in the meantime).
|
||||
</p>
|
||||
|
||||
## {% linkable_title Base Configuration %}
|
||||
|
||||
To retrieve data from OpenUV, add the following to your `configuration.yaml`
|
||||
file:
|
||||
|
||||
```yaml
|
||||
openuv:
|
||||
api_key: YOUR_OPENUV_API_KEY
|
||||
```
|
||||
|
||||
To configure additional functionality, add configuration options beneath
|
||||
a `binary_sensor` and/or `sensor` key within the `openuv` section of
|
||||
`configuration.yaml` as below:
|
||||
|
||||
```yaml
|
||||
openuv:
|
||||
api_key: YOUR_OPENUV_API_KEY
|
||||
binary_sensors:
|
||||
# binary sensor configuration options...
|
||||
sensors:
|
||||
# sensor configuration options...
|
||||
```
|
||||
|
||||
{% configuration %}
|
||||
api_key:
|
||||
description: your OpenUV API key
|
||||
required: true
|
||||
type: string
|
||||
scan_interval:
|
||||
description: the frequency (in seconds) between data updates
|
||||
required: false
|
||||
type: int
|
||||
default: 1800
|
||||
binary_sensors:
|
||||
description: binary sensor-related configuration options
|
||||
required: false
|
||||
type: map
|
||||
keys:
|
||||
monitored_conditions:
|
||||
description: the conditions to create sensors from
|
||||
required: false
|
||||
type: list
|
||||
default: all (`uv_protection_window`)
|
||||
sensors:
|
||||
description: sensor-related configuration options
|
||||
required: false
|
||||
type: map
|
||||
keys:
|
||||
monitored_conditions:
|
||||
description: the conditions to create sensors from
|
||||
required: false
|
||||
type: list
|
||||
default: all ( `current_ozone_index`, `current_uv_index`, `max_uv_index`, `safe_exposure_time_type_1`, `safe_exposure_time_type_2`, `safe_exposure_time_type_3`, `safe_exposure_time_type_4`, `safe_exposure_time_type_5`, `safe_exposure_time_type_6` )
|
||||
{% endconfiguration %}
|
||||
|
||||
## {% linkable_title Binary Sensor Types %}
|
||||
|
||||
### {% linkable_title `uv_protection_window` %}
|
||||
|
||||
This sensor displays `true` if UV protection (sunscreen, etc.) is recommended
|
||||
at the current date and time; displays `false` otherwise.
|
||||
|
||||
## {% linkable_title Sensor Types %}
|
||||
|
||||
### {% linkable_title `current_ozone_level` %}
|
||||
|
||||
This sensor displays the current ozone level in du (Dobson Units).
|
||||
|
||||
### {% linkable_title `current_uv_index` %}
|
||||
|
||||
This sensor displays the current UV index.
|
||||
|
||||
### {% linkable_title `max_uv_index` %}
|
||||
|
||||
This sensor displays the maximum UV index that will be encountered that day (at
|
||||
solar noon).
|
||||
|
||||
### {% linkable_title `safe_exposure_time_type_X` %}
|
||||
|
||||
These sensors display the approximate number of minutes a particular skin type
|
||||
can be exposed to the sun before burning/tanning starts. Each sensor depicts
|
||||
a skin type based on the
|
||||
[Fitzpatrick scale](https://en.wikipedia.org/wiki/Fitzpatrick_scale):
|
||||
|
||||
* Skin Type I
|
||||
* Skin Type II
|
||||
* Skin Type III
|
||||
* Skin Type IV
|
||||
* Skin Type V
|
||||
* Skin Type VI
|
||||
|
||||
<p class='note warning'>
|
||||
The above guidelines constitude estimates and are intended to help informed
|
||||
decision making. They should not replace analysis, advice, or diagnosis from a
|
||||
trained medical professional.
|
||||
</p>
|
23
source/_components/sensor.openuv.markdown
Normal file
23
source/_components/sensor.openuv.markdown
Normal file
@ -0,0 +1,23 @@
|
||||
---
|
||||
layout: page
|
||||
title: "OpenUV Sensor"
|
||||
description: "Instructions on how to integrate OpenUV sensors within Home Assistant."
|
||||
date: 2018-07-31 22:01
|
||||
sidebar: true
|
||||
comments: false
|
||||
sharing: true
|
||||
footer: true
|
||||
logo: openuv.jpg
|
||||
ha_category: Sensor
|
||||
ha_release: 0.76
|
||||
ha_iot_class: "Cloud Polling"
|
||||
---
|
||||
|
||||
The `openuv` sensor platform allows you to view sensor data from
|
||||
[OpenUV](http://openuv.io).
|
||||
|
||||
<p class='note'>
|
||||
You must have the [OpenUV component](/components/openuv/) configured to use
|
||||
this platform. After configuring that component, sensors will automatically
|
||||
appear.
|
||||
</p>
|
BIN
source/images/supported_brands/openuv.jpg
Normal file
BIN
source/images/supported_brands/openuv.jpg
Normal file
Binary file not shown.
After Width: | Height: | Size: 3.5 KiB |
Loading…
x
Reference in New Issue
Block a user