Add 'alarm_event_occurred' attribute definition to AlarmDecoder documentation (#14060)

Add the "alarm_event_occurred" attribute's definition to the AlarmDecoder alarm panel entity. The PR for the change itself is immediately following.
This commit is contained in:
melyux 2020-08-03 09:23:32 -05:00 committed by GitHub
parent 10acbf0c24
commit a23e43eeaf
No known key found for this signature in database
GPG Key ID: 4AEE18F83AFDEB23

View File

@ -129,6 +129,7 @@ zones:
There are several attributes available on the alarm panel to give you more information about your alarm.
- `ac_power`: Set to `true` if your system has AC power supplying it.
- `alarm_event_occurred`: Set to `true` if your system was recently triggered. When `alarm_event_occurred` is `true`, it must be cleared by entering your code + 1 (or calling the `alarm_control_panel.alarm_disarm` service) before attempting to arm your alarm.
- `backlight_on`: Set to `true` if your keypad's backlight is on.
- `battery_low`: Set to `true` if your system's back-up battery is low.
- `check_zone`: Set to `true` if your system detects a problem with a zone.