@ -47,12 +47,6 @@ The [KNX](https://www.knx.org) integration for Home Assistant allows you to conn
|
||||
|
||||
The integration requires a local KNX/IP interface or router. Through this, it will establish a connection between Home Assistant and your KNX bus.
|
||||
|
||||
<div class='note warning'>
|
||||
|
||||
Please note, the KNX platform does not support KNX Secure.
|
||||
|
||||
</div>
|
||||
|
||||
There is currently support for the following device types within Home Assistant:
|
||||
|
||||
- [Binary Sensor](#binary-sensor)
|
||||
@ -122,6 +116,31 @@ Connection parameters are set up when adding the integration and can be changed
|
||||
|
||||
Use `route back` if your tunneling server is located on a different network.
|
||||
|
||||
### KNX Secure
|
||||
|
||||
The KNX integration currently supports IP secure tunneling.
|
||||
IP secure via routing and data secure are currently not supported.
|
||||
|
||||
In order to use IP Secure you will have to chose "Tunneling" -> "TCP with IP Secure" in the config flow.
|
||||
|
||||
You can configure the IP Secure credentials either manually or by providing a `.knxkeys` file, which you can obtain by exporting the keyring in ETS as seen in the screenshot below.
|
||||
|
||||

|
||||
|
||||
The `.knxkeys` file has to be placed in `config/.storage/knx/yourfile.knxkeys`.
|
||||
|
||||
If you decide to configure IP Secure manually you will need the user ID, the user password and the device authentication password.
|
||||
|
||||
The user id 0 is reserved and the user id 1 is used for management tasks, thus you will need to specify a user id that is 2 or higher according to the tunneling channel you would like to use.
|
||||
|
||||
The following screenshot will show how you can get the device authentication password in ETS.
|
||||
|
||||

|
||||
|
||||
The user password can be obtained almost the same way as seen in the below screenshot.
|
||||
|
||||

|
||||
|
||||
## Events
|
||||
|
||||
```yaml
|
||||
|
Binary file not shown.
After Width: | Height: | Size: 22 KiB |
BIN
source/images/integrations/knx/export_keyring_ets.png
Normal file
BIN
source/images/integrations/knx/export_keyring_ets.png
Normal file
Binary file not shown.
After Width: | Height: | Size: 49 KiB |
BIN
source/images/integrations/knx/user_password.png
Normal file
BIN
source/images/integrations/knx/user_password.png
Normal file
Binary file not shown.
After Width: | Height: | Size: 42 KiB |
Loading…
x
Reference in New Issue
Block a user