add support for momentary beep/blink configuration options (#6016)

This commit is contained in:
Nate Clark 2018-08-14 15:15:50 -04:00 committed by Paulus Schoutsen
parent a80732c1f1
commit b673a41b16

View File

@ -74,7 +74,7 @@ devices:
description: The number corresponding to the _IO index_ of the labeled pin on the NodeMCU dev board. See the [NodeMCU GPIO documentation](https://nodemcu.readthedocs.io/en/master/en/modules/gpio/) for more details. Valid values are 1, 2, 5, 6, 7 and 9.
required: exclusive
zone:
description: The number corresponding to the labeled zone on the [Konnected Alarm Panel](https://konnected.io) board. Valid values are 1, 2, 3, 4, 5 and 6.
description: The number corresponding to the labeled zone on the [Konnected Alarm Panel](https://konnected.io) board. Valid values are `1`, `2`, `3`, `4`, `5` and `6`.
required: exclusive
type:
description: Any [binary sensor](/components/binary_sensor/) class, typically `door`, `window`, `motion` or `smoke`.
@ -92,16 +92,25 @@ devices:
description: The number corresponding to the _IO index_ of the labeled pin on the NodeMCU dev board. See the [NodeMCU GPIO documentation](https://nodemcu.readthedocs.io/en/master/en/modules/gpio/) for more details. Valid values are 1, 2, 5, 6, 7 and 8.
required: exclusive
zone:
description: The number corresponding to the labeled zone on the [Konnected Alarm Panel](https://konnected.io) board or the word `out` to specify the dedicated ALARM/OUT terminal on the Konnected board. Valid values are 1, 2, 3, 4, 5 and out.
description: The number corresponding to the labeled zone on the [Konnected Alarm Panel](https://konnected.io) board or the word `out` to specify the dedicated ALARM/OUT terminal on the Konnected board. Valid values are `1`, `2`, `3`, `4`, `5` and `out`.
required: exclusive
name:
description: The name of the device used in the front end.
required: false
default: automatically generated
activation:
description: Either "low" or "high" to specify the state when the switch is turned on.
description: Either `low` or `high` to specify the state when the switch is turned on.
default: high
required: false
momentary:
description: Duration of the momentary pulse in milliseconds. To make a half-second momentary contact using a relay for a garage door opener, set this value to `500`.
required: false
pause:
description: Time of the pause between pulses in milliseconds when also used with _momentary_ and _repeat_. To make a door chime "beep" with piezo buzzer, set this value to `55`, set _momentary_ to `65`, and _repeat_ to `3` or `4`.
required: false
repeat:
description: Number of times to repeat a momentary pulse. Set to `-1` to make an infinite repeat. This is useful as an alarm or warning when used with a piezo buzzer.
required: false
{% endconfiguration%}
#### {% linkable_title Configuration Notes %}
@ -109,7 +118,7 @@ devices:
- Either **pin** or **zone** is required for each actuator or sensor. Do not use both in the same definition.
- Pin `D8` or the `out` zone will only work when activation is set to high (the default).
## {% linkable_title Full configuration %}
## {% linkable_title Full Configuration %}
```yaml
# Example configuration.yaml entry
@ -121,12 +130,25 @@ konnected:
- zone: 1
type: door
name: 'Front Door'
- zone: 2
type: smoke
name: 'Bedroom Smoke Detector'
- zone: 3
type: motion
name: 'Test Motion'
switches:
- zone: out
name: siren
- zone: 5
name: 'Beep Beep'
momentary: 65
pause: 55
repeat: 4
- zone: 5
name: Warning
momentary: 65
pause: 55
repeat: -1
- id: 438a38
binary_sensors:
- pin: 1
@ -139,6 +161,9 @@ konnected:
- pin: 5
name: 'Garage Door'
activation: low
momentary: 500
- pin: 8
name: LED Light
```