diff --git a/source/_integrations/nibe_heatpump.markdown b/source/_integrations/nibe_heatpump.markdown index 1297a0665b7..a4b5cbb29ab 100644 --- a/source/_integrations/nibe_heatpump.markdown +++ b/source/_integrations/nibe_heatpump.markdown @@ -22,18 +22,16 @@ The Nibe Heat Pump integration allows you to control and monitor [Nibe Heat Pump Supported devices: -- F1145 -- F1155 -- F1245 -- F1255 -- F1345 -- F1355 +- F1145/F1155 +- S1145/S1155 +- F1245/F1255 +- F1355/F1355 - F370 - F470 - F730 - F750 -- SMO20 - SMO40 +- SMOS40 - VVM225 - VVM310 - VVM320 @@ -46,7 +44,14 @@ Supported devices: To communicate with the pump there are a few different connection methods available depending on hardware. At the moment the following methods are supported. -- [UDP Gateway using NibeGw](#udp-gateway-using-nibegw) +- [Connection Methods](#connection-methods) + - [UDP Gateway using NibeGw](#udp-gateway-using-nibegw) + - [ESPHome](#esphome) + - [Arduino](#arduino) + - [Raspberry Pi / Linux](#raspberry-pi--linux) + - [Modbus Connection](#modbus-connection) + - [TCP/IP](#tcpip) + - [RCU](#rcu) ### UDP Gateway using NibeGw @@ -75,3 +80,25 @@ A standard Linux application for running the Nibe Gateway software is also avail - [Documentation from OpenHAB](https://www.openhab.org/addons/bindings/nibeheatpump/#raspberry-pi-or-other-linux-unix-based-boards) - [Source code in OpenHAB Contrib](https://github.com/openhab/openhab-addons/tree/main/bundles/org.openhab.binding.nibeheatpump/contrib/NibeGW/RasPi) + +### Modbus Connection + +Home Assistant support connecting to Nibe heat pumps over Modbus over either TCP or RCU like connections. When connecting to the pump inside a Home Assistant, the Modbus connection string must be specified. + +#### TCP/IP + +The newer S-series pump exposes a built-in TCP Modbus server that can be used to communicate with the pump. To enable support for this integration, the pump must be connected to your local network and network (5.2 - Network settings) and Modbus (7.5.9 - Modbus TCP/IP) must be enabled. More details on the Modbus support in the pump can be found in Nibe document [M12676EN](https://partner.nibe.eu/nibedocuments/29795/M12676EN.pdf). + +- `tcp://[IP OR HOSTNAME]` +- `tcp://[IP OR HOSTNAME]:502` + +#### RCU + +If your system is equipped with a MODBUS40 accessory, this can be used to control your pump. To connect Home Assistant to the MODBUS40 accessory, a RS485 USB dongle is needed, which can be locally connected to your Home Assistant system, or on a separate computer exposed via [ser2net](https://linux.die.net/man/8/ser2net) + +- `serial://[DEVICE PATH]` for direct local connection +- `rfc2217://[IP OR HOSTNAME]:[PORT]` for a [ser2net](https://linux.die.net/man/8/ser2net) type proxy + +
+Support for RCU-based communication is currently untested. +