Update Knx climate component configuration (#7093)
* Update Knx climate component configuration * Minor fix
This commit is contained in:
parent
0c9758cb63
commit
bf3f7b7387
@ -13,7 +13,6 @@ ha_release: 0.25
|
||||
ha_iot_class: "Local Polling"
|
||||
---
|
||||
|
||||
|
||||
The `knx` climate platform is used as in interface with KNX thermostats.
|
||||
|
||||
The `knx` component must be configured correctly, see [KNX Component](/components/knx).
|
||||
@ -48,29 +47,71 @@ climate:
|
||||
operation_mode_comfort_address: '5/1/7'
|
||||
```
|
||||
|
||||
Configuration variables:
|
||||
{% configuration %}
|
||||
name:
|
||||
description: A name for this device used within Home Assistant.
|
||||
required: false
|
||||
default: KNX Climate
|
||||
type: string
|
||||
temperature_address:
|
||||
description: KNX group address for reading current room temperature from KNX bus.
|
||||
required: true
|
||||
type: string
|
||||
target_temperature_address:
|
||||
description: KNX group address for reading current target temperature from KNX bus.
|
||||
required: true
|
||||
type: string
|
||||
setpoint_shift_address:
|
||||
description: KNX address for setpoint_shift.
|
||||
required: false
|
||||
type: string
|
||||
setpoint_shift_state_address:
|
||||
description: Explicit KNX address for reading setpoint_shift.
|
||||
required: false
|
||||
type: string
|
||||
setpoint_shift_step:
|
||||
description: Defines for step size in Kelvin for each step of setpoint_shift.
|
||||
required: false
|
||||
default: 0.5
|
||||
type: float
|
||||
setpoint_shift_min:
|
||||
description: Minimum value of setpoint shift.
|
||||
required: false
|
||||
default: -6
|
||||
type: integer
|
||||
setpoint_shift_max:
|
||||
description: Maximum value of setpoint shift.
|
||||
required: false
|
||||
default: 6
|
||||
type: integer
|
||||
operation_mode_address:
|
||||
description: KNX address for operation mode (Frost protection/night/comfort).
|
||||
required: false
|
||||
type: string
|
||||
operation_mode_state_address:
|
||||
description: Explicit KNX address for reading operation mode.
|
||||
required: false
|
||||
type: string
|
||||
controller_status_address:
|
||||
description: KNX address for HVAC controller status (in accordance with KNX AN 097/07 rev 3).
|
||||
required: false
|
||||
type: string
|
||||
controller_status_state_address:
|
||||
description: Explicit KNX address for reading HVAC controller status.
|
||||
required: false
|
||||
type: string
|
||||
operation_mode_frost_protection_address:
|
||||
description: KNX address for switching on/off frost/heat protection mode.
|
||||
required: false
|
||||
type: string
|
||||
operation_mode_night_address:
|
||||
description: KNX address for switching on/off night mode.
|
||||
required: false
|
||||
type: string
|
||||
operation_mode_comfort_address:
|
||||
description: KNX address for switching on/off comfort mode.
|
||||
required: false
|
||||
type: string
|
||||
{% endconfiguration %}
|
||||
|
||||
- **name** (*Optional*): A name for this device used within Home Assistant.
|
||||
- **temperature_address**: KNX group address for reading current room temperature from KNX bus.
|
||||
- **target_temperature_address**: KNX group address for reading current target temperature from KNX bus.
|
||||
|
||||
The `knx` component sets the desired target temperature by modifying the setpoint_shift. The module provides the following configuration options:
|
||||
|
||||
* **setpoint_shift_address**: (*Optional*) KNX address for setpoint_shift
|
||||
* **setpoint_shift_state_address**: (*Optional*) Explicit KNX address for reading setpoint_shift.
|
||||
* **setpoint_shift_step**: (*Optional*) Defines for step size in Kelvin for each step of setpoint_shift. Default is 0.5 K.
|
||||
* **setpoint_shift_min**: (*Optional*) Minimum value of setpoint shift. Default is "-6".
|
||||
* **setpoint_shift_max**: (*Optional*) Maximum value of setpoint shift. Default is "6".
|
||||
|
||||
The operation modes may be controlled with the following directives:
|
||||
|
||||
- **operation_mode_address** (*Optional*): KNX address for operation mode (Frost protection/night/comfort).
|
||||
- **operation_mode_state_address** (*Optional*): Explicit KNX address for reading operation mode
|
||||
- **controller_status_address** (*Optional*): KNX address for HVAC controller status (in accordance with KNX AN 097/07 rev 3)
|
||||
- **controller_status_state_address** (*Optional*): Explicit KNX address for reading HVAC controller status
|
||||
|
||||
- **operation_mode_frost_protection_address** (*Optional*): KNX address for switching on/off frost/heat protection mode.
|
||||
- **operation_mode_night_address** (*Optional*): KNX address for switching on/off night mode.
|
||||
- **operation_mode_comfort_address** (*Optional*): KNX address for switching on/off comfort mode.
|
||||
|
||||
`operation_mode_frost_protection_address` / `operation_mode_night_address` / `operation_mode_comfort_address` are not necessary if `operation_mode_address` was specified.
|
||||
`operation_mode_frost_protection_address` / `operation_mode_night_address` / `operation_mode_comfort_address` are not necessary if `operation_mode_address` is specified.
|
||||
|