Update Knx climate component configuration (#7093)
* Update Knx climate component configuration * Minor fix
This commit is contained in:
parent
0c9758cb63
commit
bf3f7b7387
@ -13,7 +13,6 @@ ha_release: 0.25
|
|||||||
ha_iot_class: "Local Polling"
|
ha_iot_class: "Local Polling"
|
||||||
---
|
---
|
||||||
|
|
||||||
|
|
||||||
The `knx` climate platform is used as in interface with KNX thermostats.
|
The `knx` climate platform is used as in interface with KNX thermostats.
|
||||||
|
|
||||||
The `knx` component must be configured correctly, see [KNX Component](/components/knx).
|
The `knx` component must be configured correctly, see [KNX Component](/components/knx).
|
||||||
@ -48,29 +47,71 @@ climate:
|
|||||||
operation_mode_comfort_address: '5/1/7'
|
operation_mode_comfort_address: '5/1/7'
|
||||||
```
|
```
|
||||||
|
|
||||||
Configuration variables:
|
{% configuration %}
|
||||||
|
name:
|
||||||
|
description: A name for this device used within Home Assistant.
|
||||||
|
required: false
|
||||||
|
default: KNX Climate
|
||||||
|
type: string
|
||||||
|
temperature_address:
|
||||||
|
description: KNX group address for reading current room temperature from KNX bus.
|
||||||
|
required: true
|
||||||
|
type: string
|
||||||
|
target_temperature_address:
|
||||||
|
description: KNX group address for reading current target temperature from KNX bus.
|
||||||
|
required: true
|
||||||
|
type: string
|
||||||
|
setpoint_shift_address:
|
||||||
|
description: KNX address for setpoint_shift.
|
||||||
|
required: false
|
||||||
|
type: string
|
||||||
|
setpoint_shift_state_address:
|
||||||
|
description: Explicit KNX address for reading setpoint_shift.
|
||||||
|
required: false
|
||||||
|
type: string
|
||||||
|
setpoint_shift_step:
|
||||||
|
description: Defines for step size in Kelvin for each step of setpoint_shift.
|
||||||
|
required: false
|
||||||
|
default: 0.5
|
||||||
|
type: float
|
||||||
|
setpoint_shift_min:
|
||||||
|
description: Minimum value of setpoint shift.
|
||||||
|
required: false
|
||||||
|
default: -6
|
||||||
|
type: integer
|
||||||
|
setpoint_shift_max:
|
||||||
|
description: Maximum value of setpoint shift.
|
||||||
|
required: false
|
||||||
|
default: 6
|
||||||
|
type: integer
|
||||||
|
operation_mode_address:
|
||||||
|
description: KNX address for operation mode (Frost protection/night/comfort).
|
||||||
|
required: false
|
||||||
|
type: string
|
||||||
|
operation_mode_state_address:
|
||||||
|
description: Explicit KNX address for reading operation mode.
|
||||||
|
required: false
|
||||||
|
type: string
|
||||||
|
controller_status_address:
|
||||||
|
description: KNX address for HVAC controller status (in accordance with KNX AN 097/07 rev 3).
|
||||||
|
required: false
|
||||||
|
type: string
|
||||||
|
controller_status_state_address:
|
||||||
|
description: Explicit KNX address for reading HVAC controller status.
|
||||||
|
required: false
|
||||||
|
type: string
|
||||||
|
operation_mode_frost_protection_address:
|
||||||
|
description: KNX address for switching on/off frost/heat protection mode.
|
||||||
|
required: false
|
||||||
|
type: string
|
||||||
|
operation_mode_night_address:
|
||||||
|
description: KNX address for switching on/off night mode.
|
||||||
|
required: false
|
||||||
|
type: string
|
||||||
|
operation_mode_comfort_address:
|
||||||
|
description: KNX address for switching on/off comfort mode.
|
||||||
|
required: false
|
||||||
|
type: string
|
||||||
|
{% endconfiguration %}
|
||||||
|
|
||||||
- **name** (*Optional*): A name for this device used within Home Assistant.
|
`operation_mode_frost_protection_address` / `operation_mode_night_address` / `operation_mode_comfort_address` are not necessary if `operation_mode_address` is specified.
|
||||||
- **temperature_address**: KNX group address for reading current room temperature from KNX bus.
|
|
||||||
- **target_temperature_address**: KNX group address for reading current target temperature from KNX bus.
|
|
||||||
|
|
||||||
The `knx` component sets the desired target temperature by modifying the setpoint_shift. The module provides the following configuration options:
|
|
||||||
|
|
||||||
* **setpoint_shift_address**: (*Optional*) KNX address for setpoint_shift
|
|
||||||
* **setpoint_shift_state_address**: (*Optional*) Explicit KNX address for reading setpoint_shift.
|
|
||||||
* **setpoint_shift_step**: (*Optional*) Defines for step size in Kelvin for each step of setpoint_shift. Default is 0.5 K.
|
|
||||||
* **setpoint_shift_min**: (*Optional*) Minimum value of setpoint shift. Default is "-6".
|
|
||||||
* **setpoint_shift_max**: (*Optional*) Maximum value of setpoint shift. Default is "6".
|
|
||||||
|
|
||||||
The operation modes may be controlled with the following directives:
|
|
||||||
|
|
||||||
- **operation_mode_address** (*Optional*): KNX address for operation mode (Frost protection/night/comfort).
|
|
||||||
- **operation_mode_state_address** (*Optional*): Explicit KNX address for reading operation mode
|
|
||||||
- **controller_status_address** (*Optional*): KNX address for HVAC controller status (in accordance with KNX AN 097/07 rev 3)
|
|
||||||
- **controller_status_state_address** (*Optional*): Explicit KNX address for reading HVAC controller status
|
|
||||||
|
|
||||||
- **operation_mode_frost_protection_address** (*Optional*): KNX address for switching on/off frost/heat protection mode.
|
|
||||||
- **operation_mode_night_address** (*Optional*): KNX address for switching on/off night mode.
|
|
||||||
- **operation_mode_comfort_address** (*Optional*): KNX address for switching on/off comfort mode.
|
|
||||||
|
|
||||||
`operation_mode_frost_protection_address` / `operation_mode_night_address` / `operation_mode_comfort_address` are not necessary if `operation_mode_address` was specified.
|
|
||||||
|