Updated docs of climate.knx (#7899)
This commit is contained in:
parent
9df4872718
commit
c0217b9f08
@ -47,6 +47,25 @@ climate:
|
||||
operation_mode_comfort_address: '5/1/7'
|
||||
```
|
||||
|
||||
If you want to overwrite the supported operation modes use:
|
||||
|
||||
```yaml
|
||||
# Example configuration.yaml entry
|
||||
climate:
|
||||
- platform: knx
|
||||
name: HASS-Kitchen.Temperature
|
||||
temperature_address: '5/1/1'
|
||||
setpoint_shift_address: '5/1/2'
|
||||
setpoint_shift_state_address: '5/1/3'
|
||||
target_temperature_address: '5/1/4'
|
||||
operation_mode_frost_protection_address: '5/1/5'
|
||||
operation_mode_comfort_address: '5/1/7'
|
||||
override_supported_operation_modes:
|
||||
- "Night"
|
||||
- "Standby"
|
||||
- "Comfort"
|
||||
```
|
||||
|
||||
{% configuration %}
|
||||
name:
|
||||
description: A name for this device used within Home Assistant.
|
||||
@ -112,6 +131,41 @@ operation_mode_comfort_address:
|
||||
description: KNX address for switching on/off comfort mode.
|
||||
required: false
|
||||
type: string
|
||||
override_supported_operation_modes:
|
||||
description: Defines the supported operation modes.
|
||||
required: false
|
||||
type: array
|
||||
on_off_address:
|
||||
description: KNX address for switching the device on/off.
|
||||
required: false
|
||||
type: string
|
||||
on_off_state_address:
|
||||
description: Explicit KNX address for reading the current on/off status.
|
||||
required: false
|
||||
type: string
|
||||
{% endconfiguration %}
|
||||
|
||||
`operation_mode_frost_protection_address` / `operation_mode_night_address` / `operation_mode_comfort_address` are not necessary if `operation_mode_address` is specified.
|
||||
|
||||
`override_supported_operation_modes` is an array that can contain any of the following values:
|
||||
|
||||
- Auto
|
||||
- Comfort
|
||||
- Standby
|
||||
- Night
|
||||
- Frost Protection
|
||||
- Heat
|
||||
- Morning Warmup
|
||||
- Cool
|
||||
- Night Purge
|
||||
- Precool
|
||||
- Off
|
||||
- Test
|
||||
- Emergency Heat
|
||||
- Fan only
|
||||
- Ice
|
||||
- Dry
|
||||
- NoDem
|
||||
|
||||
Also check [this](https://github.com/XKNX/xknx/blob/master/xknx/knx/dpt_hvac_mode.py#L13-L30) page for more information.
|
||||
|
||||
|