Fix broken links in enphase envoy docs (#37862)

This commit is contained in:
Arie Catsman 2025-03-07 19:25:35 +01:00 committed by GitHub
parent 2743ce0d24
commit c13d3cf00c
No known key found for this signature in database
GPG Key ID: B5690EEEBB952194

View File

@ -42,7 +42,7 @@ This integration does not work with:
## Prerequisites
- The <abbr title="IQ Gateway">Envoy</abbr> must be configured and commissioned.
- The <abbr title="IQ Gateway">Envoy</abbr> must be on your local network with IPV4 connectivity from Home Assistant. (Also See troubleshooting, [single network](#single-network))
- The <abbr title="IQ Gateway">Envoy</abbr> must be on your local network with IPV4 connectivity from Home Assistant. (Also See troubleshooting, [periodic network connection issues](#periodic-network-connection-issues))
- <abbr title="IQ Gateway">Envoy</abbr> firmware version 3.9 or newer.
- With <abbr title="IQ Gateway">Envoy</abbr> firmware 7 and greater:
- an Enlighten cloud username and password.
@ -193,7 +193,7 @@ CT measure multiple properties of the energy exchange which are available as Env
- **Envoy <abbr title="Envoy serial number">SN</abbr> Production CT current**: Current in A.
- **Envoy <abbr title="Envoy serial number">SN</abbr> Powerfactor production CT**: Powerfactor, ratio of active to apparent power.
- **Envoy <abbr title="Envoy serial number">SN</abbr> Metering status production CT**: Status of the metering process: `normal`, `not-metering`, `check-wiring`.
- **Envoy <abbr title="Envoy serial number">SN</abbr> Meter status flags active production CT**: Count of CT status flags active. See troubleshooting [CT Active flag count](#ct-active-flag-count) when non-zero.
- **Envoy <abbr title="Envoy serial number">SN</abbr> Meter status flags active production CT**: Count of CT status flags active. See troubleshooting [CT Active flag count is non-zero](#ct-active-flag-count-is-non-zero) when non-zero.
##### Net-consumption CT sensor entities
@ -202,7 +202,7 @@ CT measure multiple properties of the energy exchange which are available as Env
- **Envoy <abbr title="Envoy serial number">SN</abbr> net consumption CT current**: Current in A.
- **Envoy <abbr title="Envoy serial number">SN</abbr> Powerfactor net consumption CT**: Power factor, ratio of active to apparent power.
- **Envoy <abbr title="Envoy serial number">SN</abbr> Metering status net consumption CT**: Status of the metering process: `normal`, `not-metering`, `check-wiring`.
- **Envoy <abbr title="Envoy serial number">SN</abbr> Meter status flags active net consumption CT**: Count of CT status flags active. See troubleshooting [CT Active flag count](#ct-active-flag-count) when non-zero.
- **Envoy <abbr title="Envoy serial number">SN</abbr> Meter status flags active net consumption CT**: Count of CT status flags active. See troubleshooting [CT Active flag count is non-zero](#ct-active-flag-count-is-non-zero) when non-zero.
##### Storage CT sensor entities
@ -211,7 +211,7 @@ CT measure multiple properties of the energy exchange which are available as Env
- **Envoy <abbr title="Envoy serial number">SN</abbr> storage CT current**: Current in A.
- **Envoy <abbr title="Envoy serial number">SN</abbr> Powerfactor storage CT**: Power factor, ratio of active to apparent power.
- **Envoy <abbr title="Envoy serial number">SN</abbr> Metering status storage CT**: Status of the metering process: `normal`, `not-metering`, `check-wiring`.
- **Envoy <abbr title="Envoy serial number">SN</abbr> Meter status flags active storage CT**: Count of CT status flags active. See troubleshooting [CT Active flag count](#ct-active-flag-count) when non-zero.
- **Envoy <abbr title="Envoy serial number">SN</abbr> Meter status flags active storage CT**: Count of CT status flags active. See troubleshooting [CT Active flag count is non-zero](#ct-active-flag-count-is-non-zero) when non-zero.
For storage CT energy entities refer to [battery sensor](#aggregated-iq-battery-sensor-entities) description.
@ -403,7 +403,7 @@ With installed <abbr title="current transformers">CT</abbr>, data granularity in
This integration supports updating the Envoy configuration through a `reconfigure` menu option. The reconfiguration allows for changing the Envoy IP address, username, and/or password. Use this menu option if your Enlighten credentials or the device's IP address has changed and needs to be manually updated. The latter is typically automatically detected and updated.
Use this menu option also when an Envoy firmware upgrade requires a switch from local Envoy username/password to token-based authentication with Enlighten username/password (refer to [authentication requirements](#envoy-authentication-requirements)).
Use this menu option also when an Envoy firmware upgrade requires a switch from local Envoy username/password to token-based authentication with Enlighten username/password (refer to [required manual input](#required-manual-input)).
## Firmware updates