mirror of
https://github.com/home-assistant/home-assistant.io.git
synced 2025-07-12 20:06:52 +00:00
Ecoal boiler (#7707)
* Added components.ecoal_boiler docs. * Sensors and pumps control for ecoal_boiler. * Follow configuration layout changes made during component PR review. * Update 'ha_release' * Update 'ha_release' * Delete platform docs * Remove platform docs * Add redirects * Various fixes
This commit is contained in:
parent
7e5647a3bc
commit
c604556a86
78
source/_components/ecoal_boiler.markdown
Normal file
78
source/_components/ecoal_boiler.markdown
Normal file
@ -0,0 +1,78 @@
|
||||
---
|
||||
layout: page
|
||||
title: "eCoal water boiler controller"
|
||||
description: "Instructions on how to integrate eSterownik.pl eCoal.pl controller into Home Assistant."
|
||||
date: 2018-11-29 10:00
|
||||
sidebar: true
|
||||
comments: false
|
||||
sharing: true
|
||||
footer: true
|
||||
# logo: raspberry-pi.png
|
||||
ha_category: Water heater
|
||||
ha_release: 0.87
|
||||
ha_iot_class: "Local Polling"
|
||||
redirect_from:
|
||||
- /components/sensor.ecoal_boiler/
|
||||
- /components/switch.ecoal_boiler/
|
||||
---
|
||||
|
||||
The `ecoal_boiler` component is the base for pumps and sensors managed by [esterownik.pl eCoal boiler controller](https://esterownik.pl/nasze-produkty/ecoal).
|
||||
|
||||
## {% linkable_title Configuration %}
|
||||
|
||||
To use your eCoal pumps or sensors in your installation, add the following to your `configuration.yaml` file:
|
||||
|
||||
```yaml
|
||||
# Example configuration.yaml entry
|
||||
ecoal_boiler:
|
||||
host: YOUR_IP_ADDRESS
|
||||
username: YOUR_USERNAME
|
||||
password: YOUR_PASSWORD
|
||||
switches:
|
||||
monitored_conditions:
|
||||
- central_heating_pump
|
||||
- central_heating_pump2
|
||||
sensors:
|
||||
monitored_conditions:
|
||||
- outdoor_temp
|
||||
- indoor_temp
|
||||
```
|
||||
|
||||
{% configuration %}
|
||||
host:
|
||||
description: The IP address or the hostname of eCoal controller.
|
||||
required: true
|
||||
type: string
|
||||
username:
|
||||
description: Login used to connect to controller.
|
||||
required: false
|
||||
default: admin
|
||||
type: string
|
||||
password:
|
||||
description: Password for username.
|
||||
required: false
|
||||
default: admin
|
||||
type: string
|
||||
switches:
|
||||
description: switch-related configuration options
|
||||
required: false
|
||||
type: map
|
||||
keys:
|
||||
monitored_conditions:
|
||||
description: controller available source of switches
|
||||
required: false
|
||||
type: list
|
||||
default: all (`central_heating_pump`, `central_heating_pump2`, `domestic_hot_water_pump`)
|
||||
sensors:
|
||||
description: sensor-related configuration options
|
||||
required: false
|
||||
type: map
|
||||
keys:
|
||||
monitored_conditions:
|
||||
description: controller available source of sensors
|
||||
required: false
|
||||
type: list
|
||||
default: all (`outdoor_temp`, `indoor_temp`, `indoor2_temp`, `domestic_hot_water_temp`, `target_domestic_hot_water_temp`,
|
||||
`feedwater_in_temp`, `feedwater_out_temp`, `target_feedwater_temp`,
|
||||
`fuel_feeder_temp`, `exhaust_temp`)
|
||||
{% endconfiguration %}
|
Loading…
x
Reference in New Issue
Block a user