The `opentherm_gw` component is used to control the [OpenTherm Gateway](http://otgw.tclcode.com/) from Home Assistant.
|
||||
|
||||
There is currently support for the following device types within Home Assistant:
|
||||
|
||||
- Binary Sensor
|
||||
- Climate
|
||||
- Sensor
|
||||
|
||||
When enabled, this component will automatically add its [`climate` entity](/components/climate.opentherm_gw) to Home Assistant.
|
||||
This component will add a single `climate` entity and multiple `sensor` and `binary_sensor` entities to Home Assistant for each configured gateway.
|
||||
|
||||
<p class='note'>
|
||||
The OpenTherm protocol is based on polling. The thermostat sends requests to the boiler at specific intervals. As a result, it may take some time for changes to propagate between Home Assistant and the thermostat.
|
||||
</p>
|
||||
|
||||
# {% linkable_title Configuration %}
|
||||
|
||||
In this example, one gateway is configured with `gateway_id` `living_room`.
|
||||
```yaml
|
||||
# Example configuration.yaml entry
|
||||
opentherm_gw:
|
||||
living_room:
|
||||
device: /dev/ttyUSB0
|
||||
```
|
||||
|
||||
Each configured gateway accepts the following configuration options.
|
||||
{% configuration %}
|
||||
device:
|
||||
description: "Path to OpenTherm Gateway device as supported by [PySerial](https://pythonhosted.org/pyserial/url_handlers.html)."
|
||||
required: true
|
||||
type: string
|
||||
name:
|
||||
description: "The friendly name used for the entities added for the gateway."
|
||||
required: false
|
||||
type: string
|
||||
default: "The `gateway_id` of the gateway."
|
||||
climate:
|
||||
description: "Settings for the `opentherm_gw` climate entity."
|
||||
required: false
|
||||
type: map
|
||||
keys:
|
||||
name:
|
||||
description: "The name for the device within Home Assistant."
|
||||
required: false
|
||||
type: string
|
||||
default: "OpenTherm Gateway"
|
||||
precision:
|
||||
description: "The desired precision for this device. Can be used to match your actual thermostat's precision. Supported values are `0.1`, `0.5` and `1.0`."
|
||||
required: false
|
||||
type: float
|
||||
default: "`0.5` for Celsius and `1.0` for Fahrenheit."
|
||||
floor_temperature:
|
||||
description: "Some thermostats round all temperatures down to the lower value according to their precision. Default behavior for Home Assistant is to round temperatures to the nearest value. Set this to `true` to override Home Assistant and round to the lower value according to the configured `precision`."
|
||||
description: "Some thermostats round all temperatures down to the lower value according to their precision. Default behavior for Home Assistant is to round temperatures to the nearest value. Set this to `true` to override this behavior and round to the lower value according to the configured `precision`."
|
||||
required: false
|
||||
type: boolean
|
||||
default: false
|
||||
monitored_variables:
|
||||
description: "A list of variables to expose as sensors."
|
||||
required: false
|
||||
type: list
|
||||
keys:
|
||||
burner_hours:
|
||||
description: Boiler flame on time.
|
||||
burner_starts:
|
||||
description: Number of burner starts.
|
||||
ch_pump_hours:
|
||||
description: Central heating pump running time.
|
||||
ch_pump_starts:
|
||||
description: Number of central heating pump starts.
|
||||
ch_water_pressure:
|
||||
description: Central heating water pressure.
|
||||
ch_water_temp:
|
||||
description: Central heating water temperature.
|
||||
ch_water_temp_2:
|
||||
description: Central heating 2 water temperature.
|
||||
control_setpoint:
|
||||
description: Central heating water target temperature.
|
||||
control_setpoint_2:
|
||||
description: Central heating 2 water target temperature.
|
||||
cooling_control:
|
||||
description: Cooling control signal value.
|
||||
dhw_burner_hours:
|
||||
description: Hot water flame on time.
|
||||
dhw_burner_starts:
|
||||
description: Number of hot water burner starts.
|
||||
dhw_flow_rate:
|
||||
description: Hot water flow rate.
|
||||
dhw_pump_hours:
|
||||
description: Hot water pump running time.
|
||||
dhw_pump_starts:
|
||||
description: Number of hot water pump starts.
|
||||
dhw_setpoint:
|
||||
description: Hot water target temperature.
|
||||
dhw_temp:
|
||||
description: Hot water temperature.
|
||||
dhw_temp_2:
|
||||
description: Hot water 2 temperature.
|
||||
exhaust_temp:
|
||||
description: Boiler exhaust temperature.
|
||||
master_ch2_enabled:
|
||||
description: Thermostat requests central heating 2 on.
|
||||
master_ch_enabled:
|
||||
description: Thermostat requests central heating on.
|
||||
master_cooling_enabled:
|
||||
description: Thermostat requests cooling.
|
||||
master_dhw_enabled:
|
||||
description: Thermostat requests hot water to be heated.
|
||||
master_memberid:
|
||||
description: Thermostat member ID.
|
||||
master_ot_version:
|
||||
description: Thermostat OpenTherm protocol version.
|
||||
master_otc_enabled:
|
||||
description: Thermostat is using outside temperature correction.
|
||||
master_product_type:
|
||||
description: Thermostat product type.
|
||||
master_product_version:
|
||||
description: Thermostat product version.
|
||||
max_ch_setpoint:
|
||||
description: Boiler maximum central heating water temperature.
|
||||
oem_diag:
|
||||
description: OEM diagnostic information.
|
||||
otgw_about:
|
||||
description: OpenTherm Gateway firmware version.
|
||||
otgw_build:
|
||||
description: OpenTherm Gateway firmware build date and time.
|
||||
otgw_clockmhz:
|
||||
description: OpenTherm Gateway firmware design clock speed.
|
||||
otgw_dhw_ovrd:
|
||||
description: OpenTherm Gateway hot water override status.
|
||||
otgw_gpio_a:
|
||||
description: OpenTherm Gateway GPIO port A operating mode.
|
||||
otgw_gpio_a_state:
|
||||
description: OpenTherm Gateway GPIO A state.
|
||||
otgw_gpio_b:
|
||||
description: OpenTherm Gateway GPIO port B operating mode.
|
||||
otgw_gpio_b_state:
|
||||
description: OpenTherm Gateway GPIO B state.
|
||||
otgw_ignore_transitions:
|
||||
description: OpenTherm Gateway ignores ripples in the signal during high/low transitions.
|
||||
otgw_led_a:
|
||||
description: OpenTherm Gateway LED A operating mode.
|
||||
otgw_led_b:
|
||||
description: OpenTherm Gateway LED B operating mode.
|
||||
otgw_led_c:
|
||||
description: OpenTherm Gateway LED C operating mode.
|
||||
otgw_led_d:
|
||||
description: OpenTherm Gateway LED D operating mode.
|
||||
otgw_led_e:
|
||||
description: OpenTherm Gateway LED E operating mode.
|
||||
otgw_led_f:
|
||||
description: OpenTherm Gateway LED F operating mode.
|
||||
otgw_mode:
|
||||
description: OpenTherm Gateway operating mode.
|
||||
otgw_ovrd_high_byte:
|
||||
description: OpenTherm Gateway overrides high byte with message ID 100.
|
||||
otgw_setback_temp:
|
||||
description: OpenTherm Gateway setback temperature for `away mode`.
|
||||
otgw_setpoint_ovrd_mode:
|
||||
description: OpenTherm Gateway central heating setpoint override mode.
|
||||
otgw_smart_pwr:
|
||||
description: OpenTherm Gateway smart power operating mode.
|
||||
otgw_thermostat_detect:
|
||||
description: OpenTherm Gateway automatic thermostat detection status.
|
||||
otgw_vref:
|
||||
description: OpenTherm Gateway voltage reference setting.
|
||||
outside_temp:
|
||||
description: Outside temperature as reported in the OpenTherm protocol.
|
||||
relative_mod_level:
|
||||
description: Relative modulation level.
|
||||
remote_rw_dhw:
|
||||
description: Boiler supports writing hot water setpoint.
|
||||
remote_rw_max_ch:
|
||||
description: Boiler supports writing maximum central heating setpoint.
|
||||
remote_transfer_dhw:
|
||||
description: Boiler supports reading hot water setpoint.
|
||||
remote_transfer_max_ch:
|
||||
description: Boiler supports reading maximum central heating setpoint.
|
||||
return_water_temp:
|
||||
description: Boiler return water temperature.
|
||||
room_setpoint:
|
||||
description: Room target temperature.
|
||||
room_setpoint_2:
|
||||
description: Room 2 target temperature.
|
||||
room_setpoint_ovrd:
|
||||
description: Room target temperature override value.
|
||||
room_temp:
|
||||
description: Current room temperature.
|
||||
rovrd_auto_prio:
|
||||
description: Programmed room setpoint change takes priority over remote override setting.
|
||||
rovrd_man_prio:
|
||||
description: Manual room setpoint change takes priority over remote override setting.
|
||||
slave_air_pressure_fault:
|
||||
description: Boiler reports air pressure fault.
|
||||
slave_ch2_active:
|
||||
description: Boiler reports central heating 2 active.
|
||||
slave_ch2_present:
|
||||
description: Boiler has a central heating 2 circuit.
|
||||
slave_ch_active:
|
||||
description: Boiler reports central heating active.
|
||||
slave_ch_max_setp:
|
||||
description: Maximum boiler supported central heating water target temperature.
|
||||
slave_ch_min_setp:
|
||||
description: Minimum boiler supported central heating water target temperature.
|
||||
slave_control_type:
|
||||
description: Boiler control type ('off' is modulating, 'on' is on/off).
|
||||
slave_cooling_active:
|
||||
description: Boiler reports cooling active.
|
||||
slave_cooling_supported:
|
||||
description: Boiler supports cooling.
|
||||
slave_dhw_active:
|
||||
description: Boiler reports hot water active.
|
||||
slave_dhw_config:
|
||||
description: Boiler hot water mode ('off' is instantaneous or unspecified, 'on' is storage tank).
|
||||
slave_dhw_max_setp:
|
||||
description: Maximum boiler supported hot water target temperature.
|
||||
slave_dhw_min_setp:
|
||||
description: Minimum boiler supported hot water target temperature.
|
||||
slave_dhw_present:
|
||||
description: Boiler reports hot water present.
|
||||
slave_diagnostic_indication:
|
||||
description: Boiler diagnostic indication.
|
||||
slave_fault_indication:
|
||||
description: Boiler fault indication.
|
||||
slave_flame_on:
|
||||
description: Boiler reports flame on.
|
||||
slave_gas_fault:
|
||||
description: Boiler reports gas fault.
|
||||
slave_low_water_pressure:
|
||||
description: Boiler reports low water pressure.
|
||||
slave_master_low_off_pump:
|
||||
description: Boiler supports low-off and pump control commands (this sensor is inverted, 'on' is not supported, 'off' is supported)
|
||||
slave_max_capacity:
|
||||
description: Maximum boiler capacity.
|
||||
slave_max_relative_modulation:
|
||||
description: Maximum boiler supported relative modulation.
|
||||
slave_memberid:
|
||||
description: Boiler member ID.
|
||||
slave_min_mod_level:
|
||||
description: Minimum boiler supported modulation level.
|
||||
slave_oem_fault:
|
||||
description: Boiler OEM fault indication.
|
||||
slave_ot_version:
|
||||
description: Boiler OpenTherm protocol version.
|
||||
slave_product_type:
|
||||
description: Boiler product type.
|
||||
slave_product_version:
|
||||
description: Boiler product version.
|
||||
slave_remote_reset:
|
||||
description: Boiler reports 'lockout-reset' supported.
|
||||
slave_service_required:
|
||||
description: Boiler reports service required.
|
||||
slave_water_overtemp:
|
||||
description: Boiler reports water overtemperature.
|
||||
solar_coll_temp:
|
||||
description: Solar collector temperature.
|
||||
solar_storage_temp:
|
||||
description: Solar storage unit temperature.
|
||||
{% endconfiguration %}
|
||||
|
||||
## {% linkable_title Supported Variables %}
|
||||
|
||||
The list above contains all supported variables. Note that not all boilers and thermostats properly support all variables, so the fact that a variable is listed here and published by your system does not necessarily mean that you will get useful data out of it. To see which variables are published in your situation, enable debug logging for the `opentherm_gw` component and look for the status updates.
|
||||
|
||||
# {% linkable_title Services %}
|
||||
|
||||
### {% linkable_title Service `opentherm_gw.reset_gateway` %}
|
||||
|
||||
Reset the OpenTherm Gateway.
|
||||
|
||||
This service takes no parameters.
|
||||
| Service data attribute | Optional | Description |
|
||||
| ---------------------- | -------- | ----------- |
|
||||
| `gateway_id` | no | The `gateway_id` as specified in `configuration.yaml`.
|
||||
|
||||
### {% linkable_title Service `opentherm_gw.set_clock` %}
|
||||
|
||||
@ -289,6 +82,7 @@ Provide the time and day of week to the OpenTherm Gateway. The value provided he
|
||||
|
||||
| Service data attribute | Optional | Default | Description |
|
||||
| ---------------------- | -------- | ------- | ----------- |
|
||||
| `gateway_id` | no | N/A | The `gateway_id` as specified in `configuration.yaml`.
|
||||
| `date` | yes | Today's date | Date from which the day of week will be extracted. Format: `YYYY-MM-DD`.
|
||||
| `time` | yes | Current time | Time in 24h format.
|
||||
|
||||
@ -304,6 +98,7 @@ In a normal situation, the thermostat will calculate and control the central hea
|
||||
|
||||
| Service data attribute | Optional | Description |
|
||||
| ---------------------- | -------- | ----------- |
|
||||
| `gateway_id` | no | The `gateway_id` as specified in `configuration.yaml`.
|
||||
| `temperature` | no | The central heating setpoint. Values between `0.0` and `90.0` are accepted, but your boiler may not support the full range. Set to `0` to disable the override.
|
||||
|
||||
<p class='note'>
|
||||
@ -317,6 +112,7 @@ For an explanation of the possible modes, see [GPIO modes](#gpio-modes)
|
||||
|
||||
| Service data attribute | Optional | Description |
|
||||
| ---------------------- | -------- | ----------- |
|
||||
| `gateway_id` | no | The `gateway_id` as specified in `configuration.yaml`.
|
||||
| `id` | no | The GPIO ID, `A` or `B`.
|
||||
| `mode` | no | The GPIO mode to be set.
|
||||
|
||||
@ -327,6 +123,7 @@ For a list of possible modes with explanation, see [LED modes](#led-modes)
|
||||
|
||||
| Service data attribute | Optional | Description |
|
||||
| ---------------------- | -------- | ----------- |
|
||||
| `gateway_id` | no | The `gateway_id` as specified in `configuration.yaml`.
|
||||
| `id` | no | The LED ID, accepted values are `A` through `F`.
|
||||
| `mode` | no | The LED mode to be set.
|
||||
|
||||
@ -342,6 +139,7 @@ In a normal situation, the thermostat will control the maximum modulation level
|
||||
|
||||
| Service data attribute | Optional | Description |
|
||||
| ---------------------- | -------- | ----------- |
|
||||
| `gateway_id` | no | The `gateway_id` as specified in `configuration.yaml`.
|
||||
| `level` | no | The maximum modulation level. Accepted values are `-1` through `100`. Set to `-1` to disable the override.
|
||||
|
||||
<p class='note'>
|
||||
@ -355,6 +153,7 @@ If your thermostat is unable to display an outside temperature and does not supp
|
||||
|
||||
| Service data attribute | Optional | Description |
|
||||
| ---------------------- | -------- | ----------- |
|
||||
| `gateway_id` | no | The `gateway_id` as specified in `configuration.yaml`.
|
||||
| `temperature` | no | The outside temperature to provide to the thermostat. Accepted values are `-40.0` through `64.0`. Any value above `64.0` will clear a previously configured value (suggestion: `99`).
|
||||
|
||||
### {% linkable_title Service `opentherm_gw.set_setback_temperature` %}
|
||||
@ -364,8 +163,319 @@ The value you provide here will be used with the GPIO `home` (5) and `away` (6)
|
||||
|
||||
| Service data attribute | Optional | Description |
|
||||
| ---------------------- | -------- | ----------- |
|
||||
| `gateway_id` | no | The `gateway_id` as specified in `configuration.yaml`.
|
||||
| `temperature` | no | The setback temperature. Accepted values are `0.0` through `30.0`.
|
||||
|
||||
## {% linkable_title Sensors %}
|
||||
|
||||
The following `sensor` entities will be created for each configured gateway. The `entity_id` of every sensor will have a suffix containing the `gateway_id` of the gateway to which it belongs.
|
||||
<p class='note'>
|
||||
Not all boilers and thermostats properly support all OpenTherm features, so not all of the sensors will have useful values.
|
||||
</p>
|
||||
|
||||
- **burner_hours**
|
||||
Boiler flame on time.
|
||||
|
||||
- **burner_starts**
|
||||
Number of burner starts.
|
||||
|
||||
- **ch_pump_hours**
|
||||
Central heating pump running time.
|
||||
|
||||
- **ch_pump_starts**
|
||||
Number of central heating pump starts.
|
||||
|
||||
- **ch_water_pressure**
|
||||
Central heating water pressure.
|
||||
|
||||
- **ch_water_temp**
|
||||
Central heating water temperature.
|
||||
|
||||
- **ch_water_temp_2**
|
||||
Central heating 2 water temperature.
|
||||
|
||||
- **control_setpoint**
|
||||
Central heating water target temperature.
|
||||
|
||||
- **control_setpoint_2**
|
||||
Central heating 2 water target temperature.
|
||||
|
||||
- **cooling_control**
|
||||
Cooling control signal value.
|
||||
|
||||
- **dhw_burner_hours**
|
||||
Hot water flame on time.
|
||||
|
||||
- **dhw_burner_starts**
|
||||
Number of hot water burner starts.
|
||||
|
||||
- **dhw_flow_rate**
|
||||
Hot water flow rate.
|
||||
|
||||
- **dhw_pump_hours**
|
||||
Hot water pump running time.
|
||||
|
||||
- **dhw_pump_starts**
|
||||
Number of hot water pump starts.
|
||||
|
||||
- **dhw_setpoint**
|
||||
Hot water target temperature.
|
||||
|
||||
- **dhw_temp**
|
||||
Hot water temperature.
|
||||
|
||||
- **dhw_temp_2**
|
||||
Hot water 2 temperature.
|
||||
|
||||
- **exhaust_temp**
|
||||
Boiler exhaust temperature.
|
||||
|
||||
- **master_memberid**
|
||||
Thermostat member ID.
|
||||
|
||||
- **master_ot_version**
|
||||
Thermostat OpenTherm protocol version.
|
||||
|
||||
- **master_product_type**
|
||||
Thermostat product type.
|
||||
|
||||
- **master_product_version**
|
||||
Thermostat product version.
|
||||
|
||||
- **max_ch_setpoint**
|
||||
Boiler maximum central heating water temperature.
|
||||
|
||||
- **oem_diag**
|
||||
OEM diagnostic information.
|
||||
|
||||
- **otgw_about**
|
||||
OpenTherm Gateway firmware version.
|
||||
|
||||
- **otgw_build**
|
||||
OpenTherm Gateway firmware build date and time.
|
||||
|
||||
- **otgw_clockmhz**
|
||||
OpenTherm Gateway firmware design clock speed.
|
||||
|
||||
- **otgw_dhw_ovrd**
|
||||
OpenTherm Gateway hot water override status.
|
||||
|
||||
- **otgw_gpio_a**
|
||||
OpenTherm Gateway GPIO port A operating mode.
|
||||
|
||||
- **otgw_gpio_b**
|
||||
OpenTherm Gateway GPIO port B operating mode.
|
||||
|
||||
- **otgw_led_a**
|
||||
OpenTherm Gateway LED A operating mode.
|
||||
|
||||
- **otgw_led_b**
|
||||
OpenTherm Gateway LED B operating mode.
|
||||
|
||||
- **otgw_led_c**
|
||||
OpenTherm Gateway LED C operating mode.
|
||||
|
||||
- **otgw_led_d**
|
||||
OpenTherm Gateway LED D operating mode.
|
||||
|
||||
- **otgw_led_e**
|
||||
OpenTherm Gateway LED E operating mode.
|
||||
|
||||
- **otgw_led_f**
|
||||
OpenTherm Gateway LED F operating mode.
|
||||
|
||||
- **otgw_mode**
|
||||
OpenTherm Gateway operating mode.
|
||||
|
||||
- **otgw_setback_temp**
|
||||
OpenTherm Gateway setback temperature for `away mode`.
|
||||
|
||||
- **otgw_setpoint_ovrd_mode**
|
||||
OpenTherm Gateway central heating setpoint override mode.
|
||||
|
||||
- **otgw_smart_pwr**
|
||||
OpenTherm Gateway smart power operating mode.
|
||||
|
||||
- **otgw_thermostat_detect**
|
||||
OpenTherm Gateway automatic thermostat detection status.
|
||||
|
||||
- **otgw_vref**
|
||||
OpenTherm Gateway voltage reference setting.
|
||||
|
||||
- **outside_temp**
|
||||
Outside temperature as reported in the OpenTherm protocol.
|
||||
|
||||
- **relative_mod_level**
|
||||
Relative modulation level.
|
||||
|
||||
- **return_water_temp**
|
||||
Boiler return water temperature.
|
||||
|
||||
- **room_setpoint**
|
||||
Room target temperature.
|
||||
|
||||
- **room_setpoint_2**
|
||||
Room 2 target temperature.
|
||||
|
||||
- **room_setpoint_ovrd**
|
||||
Room target temperature override value.
|
||||
|
||||
- **room_temp**
|
||||
Current room temperature.
|
||||
|
||||
- **slave_ch_max_setp**
|
||||
Maximum boiler supported central heating water target temperature.
|
||||
|
||||
- **slave_ch_min_setp**
|
||||
Minimum boiler supported central heating water target temperature.
|
||||
|
||||
- **slave_dhw_max_setp**
|
||||
Maximum boiler supported hot water target temperature.
|
||||
|
||||
- **slave_dhw_min_setp**
|
||||
Minimum boiler supported hot water target temperature.
|
||||
|
||||
- **slave_max_capacity**
|
||||
Maximum boiler capacity.
|
||||
|
||||
- **slave_max_relative_modulation**
|
||||
Maximum boiler supported relative modulation.
|
||||
|
||||
- **slave_memberid**
|
||||
Boiler member ID.
|
||||
|
||||
- **slave_min_mod_level**
|
||||
Minimum boiler supported modulation level.
|
||||
|
||||
- **slave_oem_fault**
|
||||
Boiler OEM fault indication.
|
||||
|
||||
- **slave_ot_version**
|
||||
Boiler OpenTherm protocol version.
|
||||
|
||||
- **slave_product_type**
|
||||
Boiler product type.
|
||||
|
||||
- **slave_product_version**
|
||||
Boiler product version.
|
||||
|
||||
- **solar_coll_temp**
|
||||
Solar collector temperature.
|
||||
|
||||
- **solar_storage_temp**
|
||||
Solar storage unit temperature.
|
||||
|
||||
|
||||
## {% linkable_title Binary Sensors %}
|
||||
|
||||
The following `binary_sensor` entities will be created for each configured gateway. The `entity_id` of every sensor will have a suffix containing the `gateway_id` of the gateway to which it belongs.
|
||||
<p class='note'>
|
||||
Not all boilers and thermostats properly support all OpenTherm features, so not all of the sensors will have useful values.
|
||||
</p>
|
||||
|
||||
- **master_ch2_enabled**
|
||||
Thermostat requests central heating 2 on.
|
||||
|
||||
- **master_ch_enabled**
|
||||
Thermostat requests central heating on.
|
||||
|
||||
- **master_cooling_enabled**
|
||||
Thermostat requests cooling.
|
||||
|
||||
- **master_dhw_enabled**
|
||||
Thermostat requests hot water to be heated.
|
||||
|
||||
- **master_otc_enabled**
|
||||
Thermostat is using outside temperature correction.
|
||||
|
||||
- **otgw_gpio_a_state**
|
||||
OpenTherm Gateway GPIO A state.
|
||||
|
||||
- **otgw_gpio_b_state**
|
||||
OpenTherm Gateway GPIO B state.
|
||||
|
||||
- **otgw_ignore_transitions**
|
||||
OpenTherm Gateway ignores ripples in the signal during high/low transitions.
|
||||
|
||||
- **otgw_ovrd_high_byte**
|
||||
OpenTherm Gateway overrides high byte with message ID 100.
|
||||
|
||||
- **remote_rw_dhw**
|
||||
Boiler supports writing hot water setpoint.
|
||||
|
||||
- **remote_rw_max_ch**
|
||||
Boiler supports writing maximum central heating setpoint.
|
||||
|
||||
- **remote_transfer_dhw**
|
||||
Boiler supports reading hot water setpoint.
|
||||
|
||||
- **remote_transfer_max_ch**
|
||||
Boiler supports reading maximum central heating setpoint.
|
||||
|
||||
- **rovrd_auto_prio**
|
||||
Programmed room setpoint change takes priority over remote override setting.
|
||||
|
||||
- **rovrd_man_prio**
|
||||
Manual room setpoint change takes priority over remote override setting.
|
||||
|
||||
- **slave_air_pressure_fault**
|
||||
Boiler reports air pressure fault.
|
||||
|
||||
- **slave_ch2_active**
|
||||
Boiler reports central heating 2 active.
|
||||
|
||||
- **slave_ch2_present**
|
||||
Boiler has a central heating 2 circuit.
|
||||
|
||||
- **slave_ch_active**
|
||||
Boiler reports central heating active.
|
||||
|
||||
- **slave_control_type**
|
||||
Boiler control type ('off' is modulating, 'on' is on/off).
|
||||
|
||||
- **slave_cooling_active**
|
||||
Boiler reports cooling active.
|
||||
|
||||
- **slave_cooling_supported**
|
||||
Boiler supports cooling.
|
||||
|
||||
- **slave_dhw_active**
|
||||
Boiler reports hot water active.
|
||||
|
||||
- **slave_dhw_config**
|
||||
Boiler hot water mode ('off' is instantaneous or unspecified, 'on' is storage tank).
|
||||
|
||||
- **slave_dhw_present**
|
||||
Boiler reports hot water present.
|
||||
|
||||
- **slave_diagnostic_indication**
|
||||
Boiler diagnostic indication.
|
||||
|
||||
- **slave_fault_indication**
|
||||
Boiler fault indication.
|
||||
|
||||
- **slave_flame_on**
|
||||
Boiler reports flame on.
|
||||
|
||||
- **slave_gas_fault**
|
||||
Boiler reports gas fault.
|
||||
|
||||
- **slave_low_water_pressure**
|
||||
Boiler reports low water pressure.
|
||||
|
||||
- **slave_master_low_off_pump**
|
||||
Boiler supports low-off and pump control commands (this sensor is inverted, 'on' is not supported, 'off' is supported)
|
||||
|
||||
- **slave_remote_reset**
|
||||
Boiler reports 'lockout-reset' supported.
|
||||
|
||||
- **slave_service_required**
|
||||
Boiler reports service required.
|
||||
|
||||
- **slave_water_overtemp**
|
||||
Boiler reports water overtemperature.
|
||||
|
||||
|
||||
## {% linkable_title GPIO modes %}
|
||||
|
||||
Possible modes and their meaning for the GPIO pins are listed here:
|
||||
@ -399,24 +509,21 @@ Possible LED modes and their meaning are listed here:
|
||||
* M. Boiler requires maintenance.
|
||||
* P. Raised power mode active on thermostat interface.
|
||||
|
||||
<p class='note'>
|
||||
The OpenTherm protocol is based on polling. The thermostat sends requests to the boiler at specific intervals. As a result, it may take some time for changes to propagate between Home Assistant and the thermostat.
|
||||
</p>
|
||||
|
||||
# {% linkable_title Example %}
|
||||
|
||||
A full configuration example with the OpenTherm Gateway connected to a remote host running `ser2net` looks like the one below.
|
||||
A full configuration example with two configured OpenTherm Gateways - one connected via USB, the other over the network - looks like the one below.
|
||||
|
||||
```yaml
|
||||
# Full example configuration.yaml entry
|
||||
opentherm_gw:
|
||||
living_room:
|
||||
device: /dev/ttyUSB0
|
||||
name: "Living"
|
||||
holiday_home:
|
||||
device: socket://otgw.example.org:2345
|
||||
name: "Holiday Home"
|
||||
climate:
|
||||
name: Thermostat
|
||||
precision: 0.5
|
||||
floor_temperature: true
|
||||
monitored_variables:
|
||||
- room_setpoint
|
||||
- room_temp
|
||||
- otgw_about
|
||||
```
|
||||
|
Loading…
x
Reference in New Issue
Block a user