diff --git a/source/_integrations/incomfort.markdown b/source/_integrations/incomfort.markdown index 68d0463a76e..3418ca75448 100644 --- a/source/_integrations/incomfort.markdown +++ b/source/_integrations/incomfort.markdown @@ -30,8 +30,6 @@ The boiler is represented as a **Water heater** device. It will report the boile Note that the `current_temperature` will switch between the CV (circulating volume) and Tap temperatures according to the current operating mode of the boiler. If the boiler is neither pumping nor tapping, it will be reported as the higher of the two. -In addition, there is a **Sensor** for each of CV pressure, CV temperature, and Tap temperature, and a **Binary sensor** that will be `on` if there is a fault with the boiler (the fault code will be a state attribute). - ### Rooms Any room thermostats (there can be 0, 1 or 2) are represented as **Climate** devices. They will report the thermostat's `temperature` (setpoint, target temperature) and `current_temperature` and the setpoint can be changed. @@ -52,6 +50,20 @@ Some older room thermostats might report the wrong setpoint when the setpoint is {% include integrations/option_flow.md %} +### Sensors for diagnostics + +Note that **all** sensors are disabled by default. + +- **Sensors** + - Boiler Pressure: Indicates the boilers pressure. + - Boiler Temperature: Indicates the central heating temperature. + - Boiler Tap temperature: Indicates the tap water temperature. +- **Binary sensors** + - Boiler Burner: Indicates if the burner is on. + - Boiler Fault: Indicates if there is a problem. The fault code is set as an attribute. + - Boiler Hot water tap: Indicates if the hot water tap is running. + - Boiler Pump: Indicate the pump is running for cental heating. + ## Automation To send an alert if the CV pressure is too low or too high, consider the following example: @@ -62,7 +74,7 @@ To send an alert if the CV pressure is too low or too high, consider the followi - alias: "Low CV Pressure Alert" triggers: - trigger: numeric_state - entity_id: sensor.cv_pressure + entity_id: sensor.boiler_pressure below: 1.0 actions: - action: notify.pushbullet_notifier