Add Renson services (#27767)

* add Renson endura delta integration documentation

* Fixed text lint error in renson endura delta

* Changed metadata header

* Changed integration domain to renson

* Removed manual configuration
Changed intro a bit

* Add services to renson page

* removed service that will be implemented as a number sensor

* Remove sync_time from service documentation

* removed set manual level

* Fix merge confict changes

* Removed set_day_night_time + change keys
This commit is contained in:
jimmyd-be 2023-12-07 10:52:16 +01:00 committed by GitHub
parent 6a3a114d67
commit d5377b2ea1
No known key found for this signature in database
GPG Key ID: 4AEE18F83AFDEB23

View File

@ -25,3 +25,38 @@ ha_integration_type: integration
The Renson integration pulls in data from the Renson Endura delta device. Most of the sensors that can be monitored from inside the Android/iOS application can be monitored with this integration.
{% include integrations/config_flow.md %}
## Services
### Service `renson.set_timer_level`
Set the ventilation timer.
| Service data attribute | Required | Description | Example |
| ---------------------- | -------- | ----------- | ------- |
| `timer_level`| yes | Level setting | |
| `minutes` | yes | Time of the timer (0 will disable the timer) | |
### Service `renson.set_breeze`
Set the breeze function of the ventilation system.
| Service data attribute | Required | Description | Example |
| ---------------------- | -------- | ----------- | ------- |
| `breeze_level`| no | Ventilation level when breeze function is activated | |
| `temperature` | no | Temperature when the breeze function should be activated in °C | |
| `activate` | yes | Activate or disable the breeze feature | `2020-05-01T17:45:00` |
### Service `renson.set_pollution_settings`
Set all the pollution settings of the ventilation system.
| Service data attribute | Required | Description | Example |
| ---------------------- | -------- | ----------- | ------- |
| `day_pollution_level`| no | Ventilation level when pollution is detected in the day | |
| `night_pollution_level` | no | Ventilation level when pollution is detected in the night | |
| `humidity_control` | no | Activate or disable the humidity control | |
| `airquality_control` | no | Activate or disable the air quality control | |
| `co2_control` | no | Activate or disable the CO2 control | `2020-05-01T17:45:00` |
| `co2_threshold` | no | Sets the CO2 pollution threshold level in ppm | `2020-05-01T17:45:00` |
| `co2_hysteresis` | no | Sets the CO2 pollution threshold hysteresis level in ppm | `2020-05-01T17:45:00` |