Update envirophat sensor component configuration (#7572)
This commit is contained in:
parent
5b1b1fc40a
commit
d6d3cb6e7d
@ -47,37 +47,65 @@ sensor:
|
||||
- voltage_3
|
||||
```
|
||||
|
||||
Configuration variables:
|
||||
{% configuration %}
|
||||
display_options:
|
||||
description: List of readings to monitor.
|
||||
required: false
|
||||
default: All the conditions
|
||||
type: list
|
||||
keys:
|
||||
temperature:
|
||||
description: Ambient temperature in Celsius. Since the sensor is close to the Raspberry Pi, that might affect the accuracy of the reading (ie. the Pi might heat up the sensor)
|
||||
pressure:
|
||||
description: Atmospheric pressure in hPa.
|
||||
light:
|
||||
description: Ambient light, as an integer in the 0-65535 range.
|
||||
light_red:
|
||||
description: Red color reading scaled to the ambient light, as an integer in the 0-255 range.
|
||||
light_green:
|
||||
description: Green color reading scaled to the ambient light, as an integer in the 0-255 range.
|
||||
light_blue:
|
||||
description: Blue color reading scaled to the ambient light, as an integer in the 0-255 range.
|
||||
accelerometer_x:
|
||||
description: Accelerometer reading in units of G, along the X axis.
|
||||
accelerometer_y:
|
||||
description: Accelerometer reading in units of G, along the Y axis.
|
||||
accelerometer_z:
|
||||
description: Accelerometer reading in units of G, along the Z axis.
|
||||
magnetometer_x:
|
||||
description: Magnetometer reading, the X component of the raw vector.
|
||||
magnetometer_y:
|
||||
description: Magnetometer reading, the y component of the raw vector.
|
||||
magnetometer_z:
|
||||
description: Magnetometer reading, the z component of the raw vector.
|
||||
voltage_0:
|
||||
description: Voltage reading on Analog In 0 in units of V.
|
||||
voltage_1:
|
||||
description: Voltage reading on Analog In 1 in units of V.
|
||||
voltage_2:
|
||||
description: Voltage reading on Analog In 2 in units of V.
|
||||
voltage_3:
|
||||
description: Voltage reading on Analog In 3 in units of V.
|
||||
use_led:
|
||||
description: Declaring that the on-board LEDs are *not* used for the color measurements thus these readings are based on the ambient light. If the value is set to True, the on-board LEDs will blink whenever a reading is taken.
|
||||
required: false
|
||||
default: false
|
||||
type: boolean
|
||||
{% endconfiguration %}
|
||||
|
||||
- **display_options** (*Optional*) array: List of readings to monitor. Default is monitoring all of them:
|
||||
- **temperature**: ambient temperature in Celsius. Since the sensor is close to the Raspberry Pi, that might affect the accuracy of the reading (ie. the Pi might heat up the sensor)
|
||||
- **pressure**: atmospheric pressure in hPa.
|
||||
- **light**: ambient light, as an integer in the 0-65535 range
|
||||
- **light_red**: red color reading scaled to the ambient light, as an integer in the 0-255 range
|
||||
- **light_green**: green color reading scaled to the ambient light, as an integer in the 0-255 range
|
||||
- **light_blue**: blue color reading scaled to the ambient light, as an integer in the 0-255 range
|
||||
- **accelerometer_x**: accelerometer reading in units of G, along the X axis
|
||||
- **accelerometer_y**: accelerometer reading in units of G, along the Y axis
|
||||
- **accelerometer_z**: accelerometer reading in units of G, along the Z axis
|
||||
- **magnetometer_x**: magnetometer reading, the X component of the raw vector
|
||||
- **magnetometer_y**: magnetometer reading, the Y component of the raw vector
|
||||
- **magnetometer_z**: magnetometer reading, the X component of the raw vector
|
||||
- **voltage_0**: voltage reading on Analog In 0 in units of V
|
||||
- **voltage_1**: voltage reading on Analog In 1 in units of V
|
||||
- **voltage_2**: voltage reading on Analog In 2 in units of V
|
||||
- **voltage_3**: voltage reading on Analog In 3 in units of V
|
||||
- **use_led** (*Optional*) True / False boolean; Default value is False, declaring that the on-board LEDs are *not* used for the color measurements thus these readings are based on the ambient light. If the value is set to True, the on-board LEDs will blink whenever a reading is taken.
|
||||
### {% linkable_title Notes %}
|
||||
|
||||
### Notes
|
||||
#### X, Y, Z axes
|
||||
|
||||
* **X, Y, Z axes**
|
||||
* X is parallel with the long edge of the board
|
||||
* Y is parallel with the short edge of the board
|
||||
* Z is perpendicular to the board
|
||||
* **Voltages**
|
||||
* voltage readings are done in the 0-3.3V range, please do not connect higher voltages than that! See the [Enviro pHAT's getting started guide](https://learn.pimoroni.com/tutorial/sandyj/getting-started-with-enviro-phat) regarding how to make a voltage divider
|
||||
- X is parallel with the long edge of the board
|
||||
- Y is parallel with the short edge of the board
|
||||
- Z is perpendicular to the board
|
||||
|
||||
### Give the values friendly names & icons
|
||||
#### Voltages
|
||||
|
||||
- voltage readings are done in the 0-3.3V range, please do not connect higher voltages than that! See the [Enviro pHAT's getting started guide](https://learn.pimoroni.com/tutorial/sandyj/getting-started-with-enviro-phat) regarding how to make a voltage divider
|
||||
|
||||
### {% linkable_title Give the values friendly names & icons %}
|
||||
|
||||
Add something like the following to your [customize section](/docs/configuration/customizing-devices/):
|
||||
|
||||
|