@ -28,6 +28,24 @@ Configuration variables:
- **pending_time** (*Optional*): The time in seconds of the pending time before arming the alarm. Default is 60 seconds.
- **trigger_time** (*Optional*): The time in seconds of the trigger time in which the alarm is firing. Default is 120 seconds.
- **disarm_after_trigger** (*Optional*): If true, the alarm will automatically disarm after it has been triggered instead of returning to the previous state.
- **armed_home|armed_away|armed_night|triggered** (*Optional*): State specific settings
- **pending_time**: State specific pending time override.
In the config example below, armed_home state will have no pending time and triggered state will have pending time of 20 second whereas armed_away state will have a default pending time of 30 seconds.
```yaml
# Example configuration.yaml entry
alarm_control_panel:
- platform: manual
name: Home Alarm
code: 1234
pending_time: 30
armed_home:
pending_time: 0
triggered:
pending_time: 20
trigger_time: 4
```