mirror of
https://github.com/home-assistant/home-assistant.io.git
synced 2025-07-13 20:36:52 +00:00
Migrate incomfort integration to config flow (#33040)
This commit is contained in:
parent
08aa60cac5
commit
e439e76e33
@ -17,9 +17,7 @@ ha_platforms:
|
||||
- sensor
|
||||
- water_heater
|
||||
ha_integration_type: integration
|
||||
related:
|
||||
- docs: /docs/configuration/
|
||||
title: Configuration file
|
||||
ha_config_flow: true
|
||||
---
|
||||
|
||||
The `incomfort` {% term integration %} links Home Assistant with your Intergas Lan2RF gateway, including the boiler and any room thermostats attached to it.
|
||||
@ -38,50 +36,10 @@ In addition, there is a **Sensor** for each of CV pressure, CV temperature, and
|
||||
|
||||
Any room thermostats (there can be 0, 1 or 2) are represented as **Climate** devices. They will report the thermostat's `temperature` (setpoint, target temperature) and `current_temperature` and the setpoint can be changed.
|
||||
|
||||
## Configuration
|
||||
|
||||
To set up this integration, add one of the following to your {% term "`configuration.yaml`" %} file.
|
||||
{% include integrations/restart_ha_after_config_inclusion.md %}
|
||||
{% include integrations/config_flow.md %}
|
||||
|
||||
The hub does not have to be in the same network as HA, but must be reachable via port 80/HTTP.
|
||||
|
||||
### Older gateways
|
||||
|
||||
Older gateways do not require user authentication:
|
||||
|
||||
```yaml
|
||||
# Example configuration.yaml entry, older firmware with no user credentials
|
||||
incomfort:
|
||||
host: IP_ADDRESS
|
||||
```
|
||||
|
||||
### Newer gateways
|
||||
|
||||
Alternatively, if a **username** & **password** is printed on the back of the gateway:
|
||||
|
||||
```yaml
|
||||
# Example configuration.yaml entry, newer firmware with user credentials
|
||||
incomfort:
|
||||
host: IP_ADDRESS
|
||||
username: USERNAME
|
||||
password: PASSWORD
|
||||
```
|
||||
|
||||
{% configuration %}
|
||||
host:
|
||||
description: The hostname/IP address of the Lan2RF gateway.
|
||||
required: true
|
||||
type: string
|
||||
username:
|
||||
description: "The username of the Lan2RF gateway, if any. Most likely: `admin`."
|
||||
required: inclusive
|
||||
type: string
|
||||
password:
|
||||
description: "The password of the Lan2RF gateway, if any. Most likely: `intergas`."
|
||||
required: inclusive
|
||||
type: string
|
||||
{% endconfiguration %}
|
||||
|
||||
## Automation
|
||||
|
||||
To send an alert if the CV pressure is too low or too high, consider the following example:
|
||||
|