@ -17,9 +17,7 @@ ha_platforms:
- sensor
- water_heater
ha_integration_type: integration
related:
- docs: /docs/configuration/
title: Configuration file
ha_config_flow: true
---
The `incomfort` {% term integration %} links Home Assistant with your Intergas Lan2RF gateway, including the boiler and any room thermostats attached to it.
@ -38,50 +36,10 @@ In addition, there is a **Sensor** for each of CV pressure, CV temperature, and
Any room thermostats (there can be 0, 1 or 2) are represented as **Climate** devices. They will report the thermostat's `temperature` (setpoint, target temperature) and `current_temperature` and the setpoint can be changed.
## Configuration
To set up this integration, add one of the following to your {% term "`configuration.yaml`" %} file.
{% include integrations/restart_ha_after_config_inclusion.md %}
{% include integrations/config_flow.md %}
The hub does not have to be in the same network as HA, but must be reachable via port 80/HTTP.
### Older gateways
Older gateways do not require user authentication:
```yaml
# Example configuration.yaml entry, older firmware with no user credentials
incomfort:
host: IP_ADDRESS
```
### Newer gateways
Alternatively, if a **username** & **password** is printed on the back of the gateway:
```yaml
# Example configuration.yaml entry, newer firmware with user credentials
incomfort:
host: IP_ADDRESS
username: USERNAME
password: PASSWORD
```
{% configuration %}
host:
description: The hostname/IP address of the Lan2RF gateway.
required: true
type: string
username:
description: "The username of the Lan2RF gateway, if any. Most likely: `admin`."
required: inclusive
type: string
password:
description: "The password of the Lan2RF gateway, if any. Most likely: `intergas`."
required: inclusive
type: string
{% endconfiguration %}