From f7854d92879759d1911dd5191381b857238b4c2c Mon Sep 17 00:00:00 2001 From: LvivEchoes Date: Fri, 21 Apr 2017 19:04:34 +0300 Subject: [PATCH] Add support of modbus input registers query (#2423) * Add support of modbus input registers query Documentation updated according pull request. Add support of modbus input registers query * Update sensor.modbus.markdown Removed some extra space. * Update according main PR change config option name was changed. --- source/_components/sensor.modbus.markdown | 4 ++++ 1 file changed, 4 insertions(+) diff --git a/source/_components/sensor.modbus.markdown b/source/_components/sensor.modbus.markdown index 691a755be5b..8a589ca0cf2 100644 --- a/source/_components/sensor.modbus.markdown +++ b/source/_components/sensor.modbus.markdown @@ -35,6 +35,8 @@ sensor: unit_of_measurement: °C slave: 1 register: 120 + register_type: input + data_type: float scale: 0.01 offset: -273.16 precision: 2 @@ -46,8 +48,10 @@ Configuration variables: - **name** (*Required*): Name of the sensor. - **slave** (*Required*): The number of the slave (Optional for tcp and upd Modbus). - **register** (*Required*): Register number. + - **register_type** (*Optional*): Modbus register type (holding, input), default holding - **unit_of_measurement** (*Optional*): Unit to attach to value. - **count** (*Optional*): Number of registers to read. - **scale** (*Optional*): Scale factor (output = scale * value + offset), default 1 - **offset** (*Optional*): Final offset (output = scale * value + offset), default 0 - **precision** (*Optional*): Number of valid decimals, default 0 + - **data_type** (*Optional*): Response representation (int, float). If float selected, value will be converted to IEEE 754 floating point format. default int