Add MELCloud Air-to-Water device documentation (#12159)
This commit is contained in:
parent
06bc0ca39d
commit
f84c6bdca6
@ -16,7 +16,7 @@ The `melcloud` integration integrates Mitsubishi Electric's [MELCloud](https://w
|
|||||||
## Device support
|
## Device support
|
||||||
|
|
||||||
- Air-to-Air heat pumps, e.g., AC units - **Supported**
|
- Air-to-Air heat pumps, e.g., AC units - **Supported**
|
||||||
- Air-to-Water heat pumps - **Work in progress**
|
- Air-to-Water heat pumps - **Supported**
|
||||||
- Energy recovery ventilators - **Not supported**
|
- Energy recovery ventilators - **Not supported**
|
||||||
- Other - **Not supported**
|
- Other - **Not supported**
|
||||||
|
|
||||||
@ -64,3 +64,49 @@ The following attributes are available for `sensor` platform entities:
|
|||||||
|
|
||||||
- Room temperature
|
- Room temperature
|
||||||
- Energy - The total consumed energy in kWh. **Not supported by all models.**
|
- Energy - The total consumed energy in kWh. **Not supported by all models.**
|
||||||
|
|
||||||
|
## Air-to-Water device
|
||||||
|
|
||||||
|
An Air-to-Water device provides `water_heater`, `climate` and `sensor` platforms.
|
||||||
|
|
||||||
|
### Climate
|
||||||
|
|
||||||
|
A `climate` platform entity is provided for each radiator zone in the air-to-water system. The following parameters can be controlled:
|
||||||
|
|
||||||
|
- Target room temperature
|
||||||
|
|
||||||
|
The radiators need to be configured to run in room temperature control mode either through the local HMI or MELCloud. Flow temperature and curve modes are not supported.
|
||||||
|
|
||||||
|
Some air-to-water devices allow cooling using the radiator zones. This feature has not been implemented due to the lack of sample devices.
|
||||||
|
|
||||||
|
The system cannot be turned on/off through the `climate` entities.
|
||||||
|
|
||||||
|
#### State attributes
|
||||||
|
|
||||||
|
|Attribute|Description|Example|
|
||||||
|
|---------|-----------|-------|
|
||||||
|
|`status` |Current operation status|`idle`|
|
||||||
|
|
||||||
|
### Sensor
|
||||||
|
|
||||||
|
The following attributes are available for `sensor` platform entities:
|
||||||
|
|
||||||
|
- Room temperature for each zone
|
||||||
|
- Tank water temperature
|
||||||
|
- Outside temperature - 1°C precision, polled every 1-2 hours.
|
||||||
|
|
||||||
|
Unlike air-to-air devices, air-to-water devices do not report energy consumption in an easily accessible manner.
|
||||||
|
|
||||||
|
### Water heater
|
||||||
|
|
||||||
|
The following parameters can be controlled for the `water_heater` platform entities:
|
||||||
|
|
||||||
|
- Power - Controls the entire system.
|
||||||
|
- Target tank temperature
|
||||||
|
- Operation mode
|
||||||
|
|
||||||
|
#### State attributes
|
||||||
|
|
||||||
|
|Attribute|Description|Example|
|
||||||
|
|---------|-----------|-------|
|
||||||
|
|`status` |Current operation status|`heat`|
|
||||||
|