- Climate
|
||||
- Sensor
|
||||
|
||||
This integration will add a single `climate` entity to Home Assistant for each configured gateway. Each gateway also has a collection of `sensor` and `binary_sensor` entities, which are disabled by default. These can be enabled from the `Devices` panel in the `Configuration` page of the web interface.
|
||||
This integration will add three devices to Home Assistant for each configured gateway. The main control of the integration is a single `climate` entity which can be found on the added `OpenTherm Thermostat` device. All added devices have a collection of `sensor` and `binary_sensor` entities, which are disabled by default. To enable them, follow the steps on [enabling entities](/common-tasks/general/#enabling-or-disabling-entities).
|
||||
|
||||
{% note %}
|
||||
The OpenTherm protocol is based on polling. The thermostat sends requests to the boiler at specific intervals. As a result, it may take some time for changes to propagate between Home Assistant and the thermostat.
|
||||
@ -222,315 +222,6 @@ Send a transparent [command](https://otgw.tclcode.com/firmware.html) to the Open
|
||||
| `transp_cmd` | no | The serial command to be sent to the OpenTherm Gateway. |
|
||||
| `transp_arg` | no | The serial command argument to be sent to the OpenTherm Gateway. |
|
||||
|
||||
## Sensors
|
||||
|
||||
The following `sensor` entities will be created for each configured gateway. The `entity_id` of every sensor will have a suffix containing the data source (`boiler`, `gateway` or `thermostat`) and the `gateway_id` of the gateway to which it belongs. All `sensor` entities are disabled by default.
|
||||
{% note %}
|
||||
Not all boilers and thermostats properly support all OpenTherm features, so not all of the sensors will have useful values.
|
||||
{% endnote %}
|
||||
|
||||
- **burner_hours**
|
||||
Boiler flame on time.
|
||||
|
||||
- **burner_starts**
|
||||
Number of burner starts.
|
||||
|
||||
- **ch_pump_hours**
|
||||
Central heating pump running time.
|
||||
|
||||
- **ch_pump_starts**
|
||||
Number of central heating pump starts.
|
||||
|
||||
- **ch_water_pressure**
|
||||
Central heating water pressure.
|
||||
|
||||
- **ch_water_temp**
|
||||
Central heating water temperature.
|
||||
|
||||
- **ch_water_temp_2**
|
||||
Central heating 2 water temperature.
|
||||
|
||||
- **control_setpoint**
|
||||
Central heating water target temperature.
|
||||
|
||||
- **control_setpoint_2**
|
||||
Central heating 2 water target temperature.
|
||||
|
||||
- **cooling_control**
|
||||
Cooling control signal value.
|
||||
|
||||
- **dhw_burner_hours**
|
||||
Hot water flame on time.
|
||||
|
||||
- **dhw_burner_starts**
|
||||
Number of hot water burner starts.
|
||||
|
||||
- **dhw_flow_rate**
|
||||
Hot water flow rate.
|
||||
|
||||
- **dhw_pump_hours**
|
||||
Hot water pump running time.
|
||||
|
||||
- **dhw_pump_starts**
|
||||
Number of hot water pump starts.
|
||||
|
||||
- **dhw_setpoint**
|
||||
Hot water target temperature.
|
||||
|
||||
- **dhw_temp**
|
||||
Hot water temperature.
|
||||
|
||||
- **dhw_temp_2**
|
||||
Hot water 2 temperature.
|
||||
|
||||
- **exhaust_temp**
|
||||
Boiler exhaust temperature.
|
||||
|
||||
- **master_memberid**
|
||||
Thermostat member ID.
|
||||
|
||||
- **master_ot_version**
|
||||
Thermostat OpenTherm protocol version.
|
||||
|
||||
- **master_product_type**
|
||||
Thermostat product type.
|
||||
|
||||
- **master_product_version**
|
||||
Thermostat product version.
|
||||
|
||||
- **max_ch_setpoint**
|
||||
Boiler maximum central heating water temperature.
|
||||
|
||||
- **oem_diag**
|
||||
OEM diagnostic information.
|
||||
|
||||
- **otgw_about**
|
||||
OpenTherm Gateway firmware version.
|
||||
|
||||
- **otgw_build**
|
||||
OpenTherm Gateway firmware build date and time.
|
||||
|
||||
- **otgw_clockmhz**
|
||||
OpenTherm Gateway firmware design clock speed.
|
||||
|
||||
- **otgw_dhw_ovrd**
|
||||
OpenTherm Gateway hot water override status.
|
||||
|
||||
- **otgw_gpio_a**
|
||||
OpenTherm Gateway GPIO port A operating mode.
|
||||
|
||||
- **otgw_gpio_b**
|
||||
OpenTherm Gateway GPIO port B operating mode.
|
||||
|
||||
- **otgw_led_a**
|
||||
OpenTherm Gateway LED A operating mode.
|
||||
|
||||
- **otgw_led_b**
|
||||
OpenTherm Gateway LED B operating mode.
|
||||
|
||||
- **otgw_led_c**
|
||||
OpenTherm Gateway LED C operating mode.
|
||||
|
||||
- **otgw_led_d**
|
||||
OpenTherm Gateway LED D operating mode.
|
||||
|
||||
- **otgw_led_e**
|
||||
OpenTherm Gateway LED E operating mode.
|
||||
|
||||
- **otgw_led_f**
|
||||
OpenTherm Gateway LED F operating mode.
|
||||
|
||||
- **otgw_mode**
|
||||
OpenTherm Gateway operating mode.
|
||||
|
||||
- **otgw_setback_temp**
|
||||
OpenTherm Gateway setback temperature for `away mode`.
|
||||
|
||||
- **otgw_setpoint_ovrd_mode**
|
||||
OpenTherm Gateway central heating setpoint override mode.
|
||||
|
||||
- **otgw_smart_pwr**
|
||||
OpenTherm Gateway smart power operating mode.
|
||||
|
||||
- **otgw_thermostat_detect**
|
||||
OpenTherm Gateway automatic thermostat detection status.
|
||||
|
||||
- **otgw_vref**
|
||||
OpenTherm Gateway voltage reference setting.
|
||||
|
||||
- **outside_temp**
|
||||
Outside temperature as reported in the OpenTherm protocol.
|
||||
|
||||
- **relative_mod_level**
|
||||
Relative modulation level.
|
||||
|
||||
- **return_water_temp**
|
||||
Boiler return water temperature.
|
||||
|
||||
- **room_setpoint**
|
||||
Room target temperature.
|
||||
|
||||
- **room_setpoint_2**
|
||||
Room 2 target temperature.
|
||||
|
||||
- **room_setpoint_ovrd**
|
||||
Room target temperature override value.
|
||||
|
||||
- **room_temp**
|
||||
Current room temperature.
|
||||
|
||||
- **slave_ch_max_setp**
|
||||
Maximum boiler supported central heating water target temperature.
|
||||
|
||||
- **slave_ch_min_setp**
|
||||
Minimum boiler supported central heating water target temperature.
|
||||
|
||||
- **slave_dhw_max_setp**
|
||||
Maximum boiler supported hot water target temperature.
|
||||
|
||||
- **slave_dhw_min_setp**
|
||||
Minimum boiler supported hot water target temperature.
|
||||
|
||||
- **slave_max_capacity**
|
||||
Maximum boiler capacity.
|
||||
|
||||
- **slave_max_relative_modulation**
|
||||
Maximum boiler supported relative modulation.
|
||||
|
||||
- **slave_memberid**
|
||||
Boiler member ID.
|
||||
|
||||
- **slave_min_mod_level**
|
||||
Minimum boiler supported modulation level.
|
||||
|
||||
- **slave_oem_fault**
|
||||
Boiler OEM fault indication.
|
||||
|
||||
- **slave_ot_version**
|
||||
Boiler OpenTherm protocol version.
|
||||
|
||||
- **slave_product_type**
|
||||
Boiler product type.
|
||||
|
||||
- **slave_product_version**
|
||||
Boiler product version.
|
||||
|
||||
- **solar_coll_temp**
|
||||
Solar collector temperature.
|
||||
|
||||
- **solar_storage_temp**
|
||||
Solar storage unit temperature.
|
||||
|
||||
|
||||
## Binary sensors
|
||||
|
||||
The following `binary_sensor` entities will be created for each configured gateway. The `entity_id` of every sensor will have a suffix containing the data source (`boiler`, `gateway` or `thermostat`) and the `gateway_id` of the gateway to which it belongs. All `binary_sensor` entities are disabled by default.
|
||||
{% note %}
|
||||
Not all boilers and thermostats properly support all OpenTherm features, so not all of the sensors will have useful values.
|
||||
{% endnote %}
|
||||
|
||||
- **master_ch2_enabled**
|
||||
Thermostat requests central heating 2 on.
|
||||
|
||||
- **master_ch_enabled**
|
||||
Thermostat requests central heating on.
|
||||
|
||||
- **master_cooling_enabled**
|
||||
Thermostat requests cooling.
|
||||
|
||||
- **master_dhw_enabled**
|
||||
Thermostat requests hot water to be heated.
|
||||
|
||||
- **master_otc_enabled**
|
||||
Thermostat is using outside temperature correction.
|
||||
|
||||
- **otgw_gpio_a_state**
|
||||
OpenTherm Gateway GPIO A state.
|
||||
|
||||
- **otgw_gpio_b_state**
|
||||
OpenTherm Gateway GPIO B state.
|
||||
|
||||
- **otgw_ignore_transitions**
|
||||
OpenTherm Gateway ignores ripples in the signal during high/low transitions.
|
||||
|
||||
- **otgw_ovrd_high_byte**
|
||||
OpenTherm Gateway overrides high byte with message ID 100.
|
||||
|
||||
- **remote_rw_dhw**
|
||||
Boiler supports writing hot water setpoint.
|
||||
|
||||
- **remote_rw_max_ch**
|
||||
Boiler supports writing maximum central heating setpoint.
|
||||
|
||||
- **remote_transfer_dhw**
|
||||
Boiler supports reading hot water setpoint.
|
||||
|
||||
- **remote_transfer_max_ch**
|
||||
Boiler supports reading maximum central heating setpoint.
|
||||
|
||||
- **rovrd_auto_prio**
|
||||
Programmed room setpoint change takes priority over remote override setting.
|
||||
|
||||
- **rovrd_man_prio**
|
||||
Manual room setpoint change takes priority over remote override setting.
|
||||
|
||||
- **slave_air_pressure_fault**
|
||||
Boiler reports air pressure fault.
|
||||
|
||||
- **slave_ch2_active**
|
||||
Boiler reports central heating 2 active.
|
||||
|
||||
- **slave_ch2_present**
|
||||
Boiler has a central heating 2 circuit.
|
||||
|
||||
- **slave_ch_active**
|
||||
Boiler reports central heating active.
|
||||
|
||||
- **slave_control_type**
|
||||
Boiler control type ('off' is modulating, 'on' is on/off).
|
||||
|
||||
- **slave_cooling_active**
|
||||
Boiler reports cooling active.
|
||||
|
||||
- **slave_cooling_supported**
|
||||
Boiler supports cooling.
|
||||
|
||||
- **slave_dhw_active**
|
||||
Boiler reports hot water active.
|
||||
|
||||
- **slave_dhw_config**
|
||||
Boiler hot water mode ('off' is instantaneous or unspecified, 'on' is storage tank).
|
||||
|
||||
- **slave_dhw_present**
|
||||
Boiler reports hot water present.
|
||||
|
||||
- **slave_diagnostic_indication**
|
||||
Boiler diagnostic indication.
|
||||
|
||||
- **slave_fault_indication**
|
||||
Boiler fault indication.
|
||||
|
||||
- **slave_flame_on**
|
||||
Boiler reports flame on.
|
||||
|
||||
- **slave_gas_fault**
|
||||
Boiler reports gas fault.
|
||||
|
||||
- **slave_low_water_pressure**
|
||||
Boiler reports low water pressure.
|
||||
|
||||
- **slave_master_low_off_pump**
|
||||
Boiler supports low-off and pump control commands (this sensor is inverted, 'on' is not supported, 'off' is supported)
|
||||
|
||||
- **slave_remote_reset**
|
||||
Boiler reports 'lockout-reset' supported.
|
||||
|
||||
- **slave_service_required**
|
||||
Boiler reports service required.
|
||||
|
||||
- **slave_water_overtemp**
|
||||
Boiler reports water overtemperature.
|
||||
|
||||