Statistics additional binary characteristics (#20543)
This commit is contained in:
parent
2744f0c7ef
commit
f9a8396d6d
@ -18,7 +18,7 @@ The `statistics` sensor platform observes the state of a source sensor and provi
|
||||
|
||||
The statistics sensor updates with every source sensor update. The value of the sensor represents one statistical characteristic, with `mean` being the default. The time period and/or number of recent state that should be considered is an important factor here. Check the configuration section below for options.
|
||||
|
||||
Both `sensor` and `binary_sensor` are supported as source sensor. In the case of a binary sensor only the state changes are counted.
|
||||
Both `sensor` and `binary_sensor` are supported as source sensor. A number of characteristics is supported by each, please check below.
|
||||
|
||||
Assuming the [`recorder`](/integrations/recorder/) integration is running, historical sensor data is read from the database on startup and is available immediately after a restart of the platform. If the [`recorder`](/integrations/recorder/) integration is *not* running, it can take some time for the sensor to start reporting data because some characteristics calculations require more than one source sensor value.
|
||||
|
||||
@ -26,6 +26,10 @@ Assuming the [`recorder`](/integrations/recorder/) integration is running, histo
|
||||
|
||||
The following statistical characteristics are available. Pay close attention to the right configuration of `sampling_size` and `max_age`, as most characterists are directly related to the count of samples or the age of processed samples.
|
||||
|
||||
### Numeric Source Sensor
|
||||
|
||||
The following characteristics are supported for `sensor` source sensors:
|
||||
|
||||
| State Characteristic | Description |
|
||||
| -------------------- | ----------- |
|
||||
| `average_linear` | The average value of stored measurements under consideration of the time distances between them. A linear interpolation is applied per measurement pair. Good suited to observe a source sensor with non-periodic sensor updates and when continuous behavior is represented by the measurements (e.g. outside temperature).
|
||||
@ -50,6 +54,17 @@ The following statistical characteristics are available. Pay close attention to
|
||||
| `value_min` | The smallest value among the number of measurements.
|
||||
| `variance` | The [variance](https://en.wikipedia.org/wiki/Standard_deviation) of an assumed normal distribution from all measurements.
|
||||
|
||||
### Binary Source Sensor
|
||||
|
||||
The following characteristic are supported for `binary_sensor` source sensors:
|
||||
|
||||
| State Characteristic | Description |
|
||||
| -------------------- | ----------- |
|
||||
| `average_step` | A percentage of time across all stored measurements, in which the binary source sensor was "On". If over the course of one hour, movement was detected for 6 minutes, the `average_step` is 10%.
|
||||
| `average_timeless` | The percentage of stored measurements, for which the binary source sensor was "On". Time in on/off states is ignored. If over the course of one hour, a single movement was detected, the `average_timeless` is 33.3% (assuming the stored measurements "Off", "On", "Off"). Equal to `mean`.
|
||||
| `count` | The number of stored source sensor readings. This number is limited by `sampling_size` and can be low within the bounds of `max_age`.
|
||||
| `mean` | The percentage of stored measurements, for which the binary source sensor was "On". Time in on/off states is ignored. If over the course of one hour, a single movement was detected, the `average_timeless` is 33.3% (assuming the stored measurements "Off", "On", "Off").
|
||||
|
||||
## Attributes
|
||||
|
||||
A statistics sensor presents the following attributes for context about its internal status.
|
||||
@ -69,6 +84,7 @@ sensor:
|
||||
- platform: statistics
|
||||
name: "Bathroom humidity mean over last 24 hours"
|
||||
entity_id: sensor.bathroom_humidity
|
||||
state_characteristic: mean
|
||||
max_age:
|
||||
hours: 24
|
||||
|
||||
@ -83,6 +99,7 @@ sensor:
|
||||
|
||||
- platform: statistics
|
||||
entity_id: binary_sensor.movement
|
||||
state_characteristic: count
|
||||
```
|
||||
|
||||
{% configuration %}
|
||||
@ -96,9 +113,9 @@ name:
|
||||
default: Stats
|
||||
type: string
|
||||
state_characteristic:
|
||||
description: The characteristic that should be used as the state of the statistics sensor (see table above).
|
||||
description: The characteristic that should be used as the state of the statistics sensor (see table above). **Beware** that this parameter will become mandatory in a future version. Include in your configuration. If currently omitted, the default characteristic for a `sensor` source sensor is "mean", for a `binary_sensor` "count".
|
||||
required: false
|
||||
default: mean
|
||||
default: mean / count
|
||||
type: string
|
||||
sampling_size:
|
||||
description: Maximum number of source sensor measurements stored. Be sure to choose a reasonably high number if the limit should be driven by `max_age` instead.
|
||||
@ -125,7 +142,3 @@ quantile_method:
|
||||
default: exclusive
|
||||
type: string
|
||||
{% endconfiguration %}
|
||||
|
||||