@ -47,24 +47,19 @@ climate:
|
||||
operation_mode_comfort_address: '5/1/7'
|
||||
```
|
||||
|
||||
If you want to overwrite the supported operation modes use:
|
||||
`operation_mode_frost_protection_address` / `operation_mode_night_address` / `operation_mode_comfort_address` are not necessary if `operation_mode_address` is specified.
|
||||
|
||||
```yaml
|
||||
# Example configuration.yaml entry
|
||||
climate:
|
||||
- platform: knx
|
||||
name: HASS-Kitchen.Temperature
|
||||
temperature_address: '5/1/1'
|
||||
setpoint_shift_address: '5/1/2'
|
||||
setpoint_shift_state_address: '5/1/3'
|
||||
target_temperature_address: '5/1/4'
|
||||
operation_mode_frost_protection_address: '5/1/5'
|
||||
operation_mode_comfort_address: '5/1/7'
|
||||
override_supported_operation_modes:
|
||||
- "Night"
|
||||
- "Standby"
|
||||
- "Comfort"
|
||||
```
|
||||
If your device doesn't support setpoint_shift calculations (i.e. if you don't provide a `setpoint_shift_address` value) please set the `min_temp` and `max_temp`
|
||||
attributes of the climate device to avoid issues with increasing the temperature in the frontend.
|
||||
|
||||
The following values are valid for the `operation_modes` attribute:
|
||||
|
||||
- Comfort (maps internally to STATE_HEAT within Home Assistant)
|
||||
- Standby (maps internally to STATE_ECO within Home Assistant)
|
||||
- Night (maps internally to STATE_IDLE within Home Assistant)
|
||||
- Frost Protection (maps internally to STATE_MANUAL within Home Assistant)
|
||||
- Fan only (maps internally to STATE_FAN_ONLY within Home Assistant)
|
||||
- Dehumidification (maps internally to STATE_DRY within Home Assistant)
|
||||
|
||||
{% configuration %}
|
||||
name:
|
||||
@ -119,6 +114,14 @@ controller_status_state_address:
|
||||
description: Explicit KNX address for reading HVAC controller status.
|
||||
required: false
|
||||
type: string
|
||||
controller_mode_address:
|
||||
description: KNX address for handling controller modes.
|
||||
required: false
|
||||
type: string
|
||||
controller_mode_state_address:
|
||||
description: Explicit KNX address for reading HVAC Control Mode.
|
||||
required: false
|
||||
type: string
|
||||
operation_mode_frost_protection_address:
|
||||
description: KNX address for switching on/off frost/heat protection mode.
|
||||
required: false
|
||||
@ -131,41 +134,24 @@ operation_mode_comfort_address:
|
||||
description: KNX address for switching on/off comfort mode.
|
||||
required: false
|
||||
type: string
|
||||
override_supported_operation_modes:
|
||||
description: Defines the supported operation modes.
|
||||
operation_modes:
|
||||
description: Overrides the supported operation modes.
|
||||
required: false
|
||||
type: array
|
||||
on_off_address:
|
||||
description: KNX address for switching the device on/off.
|
||||
description: KNX address for switching the climate device on/off.
|
||||
required: false
|
||||
type: string
|
||||
on_off_state_address:
|
||||
description: Explicit KNX address for reading the current on/off status.
|
||||
description: KNX address for gathering the current state (on/off) of the climate device.
|
||||
required: false
|
||||
type: string
|
||||
min_temp:
|
||||
description: Override the minimum temperature.
|
||||
required: false
|
||||
type: float
|
||||
max_temp:
|
||||
description: Override the maximum temperature.
|
||||
required: false
|
||||
type: float
|
||||
{% endconfiguration %}
|
||||
|
||||
`operation_mode_frost_protection_address` / `operation_mode_night_address` / `operation_mode_comfort_address` are not necessary if `operation_mode_address` is specified.
|
||||
|
||||
`override_supported_operation_modes` is an array that can contain any of the following values:
|
||||
|
||||
- Auto
|
||||
- Comfort
|
||||
- Standby
|
||||
- Night
|
||||
- Frost Protection
|
||||
- Heat
|
||||
- Morning Warmup
|
||||
- Cool
|
||||
- Night Purge
|
||||
- Precool
|
||||
- Off
|
||||
- Test
|
||||
- Emergency Heat
|
||||
- Fan only
|
||||
- Ice
|
||||
- Dry
|
||||
- NoDem
|
||||
|
||||
Also check [this](https://github.com/XKNX/xknx/blob/master/xknx/knx/dpt_hvac_mode.py#L13-L30) page for more information.
|
||||
|
||||
|