--- title: KNX description: Instructions on how to integrate KNX components with Home Assistant. ha_category: - Hub - Binary Sensor - Climate - Cover - Light - Notifications - Scene - Sensor - Switch - Weather ha_release: 0.24 ha_iot_class: Local Push ha_codeowners: - '@Julius2342' - '@farmio' - '@marvin-w' ha_domain: knx ha_quality_scale: silver --- The [KNX](https://www.knx.org) integration for Home Assistant allows you to connect to KNX/IP devices. The integration requires a local KNX/IP interface or router. Through this, it will establish a connection between Home Assistant and your KNX bus.
Please note, the `knx` platform does not support KNX Secure.
There is currently support for the following device types within Home Assistant: - [Binary Sensor](#binary-sensor) - [Climate](#climate) - [Cover](#cover) - [Light](#light) - [Notify](#notify) - [Scene](#scene) - [Sensor](#sensor) - [Switch](#switch) - [Weather](#weather) ## Basic Configuration To use your KNX bus in your installation, add the following lines to your `configuration.yaml` file: ```yaml knx: ``` In order to make use of the various platforms KNX offers you will need to have the following configuration inside `configuration.yaml` depending on what platforms you intend to use: ```yaml knx: binary_sensor: !include knx_binary_sensor.yaml switch: !include knx_switch.yaml sensor: !include knx_sensor.yaml cover: !include knx_cover.yaml light: !include knx_light.yaml notify: !include knx_notify.yaml scene: !include knx_scene.yaml ``` Please check the dedicated platform documentation about how to configure them correctly. Optional, or if you want to use the XKNX abstraction also for other scripted tools outside of Home Assistant: ```yaml knx: config_file: '/path/to/xknx.yaml' ``` {% configuration %} config_file: description: The path for XKNX configuration file. See [xknx.io](https://xknx.io/configuration) for details required: false type: string rate_limit: description: Defines the maximum number of telegrams to be sent to the bus per second (range 1-100). required: false default: 20 type: integer individual_address: description: The KNX individual address that shall be used for routing or if a tunnelling server doesn't assign an IA at connection. required: false type: string default: "15.15.250" multicast_group: description: The multicast group to use for automatic interface discovery and routing communication. required: false type: string default: "224.0.23.12" multicast_port: description: The port for multicast communication. required: false type: integer default: 3671 {% endconfiguration %} If the auto detection of the KNX/IP device does not work you can specify IP and port of the tunneling device: ```yaml knx: tunneling: host: '192.168.2.23' port: 3671 local_ip: '192.168.2.109' ``` {% configuration %} host: description: IP address of the KNX/IP tunneling device. type: string required: true port: description: Port of the KNX/IP tunneling device. type: integer required: false local_ip: description: IP address of the local interface. type: string required: false {% endconfiguration %} Explicit connection to a KNX/IP routing device: ```yaml knx: routing: local_ip: '192.168.2.109' ``` {% configuration %} local_ip: description: The local IP address of the interface that shall be used to send multicast packets. type: string required: true {% endconfiguration %} ```yaml knx: fire_event: true fire_event_filter: ["1/0/*", "6/2,3,4-6/*"] ``` {% configuration %} fire_event: description: If set to True, platform will write all received KNX messages to event bus required: inclusive type: boolean default: false fire_event_filter: description: If `fire_event` is set `fire_event_filter` has to be specified. `fire_event_filter` defines a list of patterns for filtering KNX addresses. Only telegrams which match this pattern are sent to the Home Assistant event bus. required: inclusive type: [list, string] state_updater: description: The integration will collect the current state of each configured device from the KNX bus to display it correctly within Home Assistant. Set this option to False to prevent this behavior. required: false default: true type: boolean {% endconfiguration %} ## Services In order to directly interact with the KNX bus, you can use the following service: ```txt Domain: knx Service: send Service Data: {"address": "1/0/15", "payload": 0, "type": "temperature"} ``` {% configuration %} address: description: KNX group address type: string payload: description: Payload to send to the bus. When `type` is not set, raw bytes are sent. Integers are then treated as DPT 1/2/3 payloads. For DPTs > 6 bits send a list. Each value represents 1 octet (0-255). Pad with 0 to DPT byte length. type: [integer, list] type: description: If set, the payload will not be sent as raw bytes, but encoded as given DPT. KNX sensor types are valid values - see table in [KNX Sensor](#sensor). type: [string, integer, float] {% endconfiguration %} You can also use the `homeassistant.update_entity` service call to issue GroupValueRead requests for all `*state_address` of a device. ## Exposing entity states, entity attributes or time to KNX bus KNX integration is able to expose entity states or attributes to KNX bus. The integration will broadcast any change of the exposed value to the KNX bus and answer read requests to the specified group address. It is also possible to expose the current time. ```yaml # Example configuration.yaml entry knx: expose: - type: 'temperature' entity_id: 'sensor.owm_temperature' address: '0/0/2' - type: 'string' address: '0/6/4' entity_id: "sensor.owm_weather" - type: 'binary' entity_id: 'binary_sensor.kitchen_window' address: '0/6/5' - type: 'binary' entity_id: 'light.office' address: '0/3/0' default: False - type: 'percentU8' entity_id: 'light.office' attribute: 'brightness' default: 0 address: '0/3/1' - type: 'time' address: '0/0/1' - type: 'datetime' address: '0/0/23' ``` {% configuration %} type: description: Type of the exposed value. Either 'binary', 'time', 'date', 'datetime' or any supported type of [KNX Sensor](#sensor) (e.g., "temperature" or "humidity"). type: string required: true entity_id: description: Entity id to be exposed. Not needed for types time, date and datetime. type: string required: false attribute: description: Attribute of the entity that shall be sent to the KNX bus. If not set (or `None`) the state will be sent. Eg. for a light the state is eigther "on" or "off" - with attribute you can expose its "brightness". type: string required: false default: description: Default value to send to the bus if the state or attribute value is `None`. Eg. a light with state "off" has no brightness attribute so a default value of `0` could be used. If not set (or `None`) no value would be sent to the bus and a GroupReadRequest to the address would return the last known value. type: [boolean, string, integer, float] default: None required: false address: description: KNX group address. type: string required: true {% endconfiguration %} The `knx` sensor platform allows you to monitor [KNX](https://www.knx.org/) binary sensors. Binary sensors are read-only. To write to the knx-bus configure an exposure [KNX Integration - Expose](/integrations/knx/#exposing-sensor-values-or-time-to-knx-bus). ## Binary Sensor To use your binary sensors please add the relevant configuration to your top level [KNX Integration](/integrations/knx) configuration key in `configuration.yaml`: ```yaml knx: binary_sensor: - name: sensor1 state_address: '6/0/2' ``` {% configuration %} state_address: description: KNX group address of the binary sensor. *DPT 1* required: true type: string name: description: A name for this device used within Home Assistant. required: false type: string sync_state: description: Actively read the value from the bus. If `False` no GroupValueRead telegrams will be sent to the bus. `sync_state` can be set to `init` to just initialize state on startup, `expire ` to read the state from the KNX bus when no telegram was received for \ or `every ` to update it regularly every \. Maximum value for \ is 1440. If just a number is configured "expire"-behaviour is used. Defaults to `True` which is interpreted as "expire 60". required: false type: [boolean, string, integer] default: True device_class: description: Sets the [class of the device](/integrations/binary_sensor/), changing the device state and icon that is displayed on the frontend. required: false type: string reset_after: description: Reset back to OFF state after specified seconds. required: false type: float invert: description: Invert the telegrams payload before processing. This is applied before `context_timeout` or `reset_after` is evaluated. required: false type: boolean default: False ignore_internal_state: description: Specifies if telegrams should ignore the internal state and always trigger a Home Assistant state update. required: false type: boolean default: False context_timeout: description: The time in seconds between multiple identical telegram payloads would count towards the internal counter that is used for automations. Ex. You have automations in place that trigger your lights on button press and another set of lights if you click that button twice. This setting defines the time that a second button press would count toward, so if you set this 3.0 you can take up to 3 seconds in order to trigger the second button press. If set `ignore_internal_state` will be set to `True` internally. Maximum value is 10.0. required: false type: float default: None {% endconfiguration %} ### Support for automations You can use a built in event in order to trigger an automation (e.g. to switch on a light when a switch was pressed). Let's pretend you have a binary sensor with the name `Livingroom.Switch` and you want to switch one light on when the button was pressed once and two other lights when the button was pressed twice. ```yaml # Example automation.yaml entry automation: - trigger: platform: numeric_state entity_id: binary_sensor.Livingroom_Switch attribute: counter above: 0 below: 2 condition: - condition: state entity_id: binary_sensor.cover_abstell state: 'on' action: - entity_id: light.hue_color_lamp_1 service: light.turn_on - trigger: platform: numeric_state entity_id: binary_sensor.Livingroom_Switch attribute: counter above: 1 below: 3 condition: - condition: state entity_id: binary_sensor.cover_abstell state: 'on' action: - entity_id: light.hue_bloom_1 service: homeassistant.turn_on - entity_id: light.hue_bloom_2 service: homeassistant.turn_on ``` {% configuration %} name: description: A name for this device used within Home Assistant. required: false type: string counter: description: Set to 2 if your only want the action to be executed if the button was pressed twice. To 3 for three times button pressed. required: false type: integer default: 1 hook: description: Indicates if the automation should be executed on what state of the binary sensor. Values are "on" or "off". required: false type: string default: "on" action: description: Specify a list of actions analog to the [automation rules](/docs/automation/action/). required: false type: list {% endconfiguration %} ## Climate The `knx` climate platform is used as an interface to KNX thermostats and room controllers. To use your KNX thermostats in your installation, add the following lines to your top level [KNX Integration](/integrations/knx) configuration key in `configuration.yaml`: ```yaml # Example configuration.yaml entry knx: climate: - name: HASS-Kitchen.Temperature temperature_address: '5/1/1' setpoint_shift_address: '5/1/2' setpoint_shift_state_address: '5/1/3' target_temperature_state_address: '5/1/4' operation_mode_address: '5/1/5' operation_mode_state_address: '5/1/6' ``` Alternatively, if your device has dedicated binary group addresses for frost/night/comfort mode: ```yaml # Example configuration.yaml entry knx: climate: - name: HASS-Kitchen.Temperature temperature_address: '5/1/1' setpoint_shift_address: '5/1/2' setpoint_shift_state_address: '5/1/3' target_temperature_state_address: '5/1/4' operation_mode_frost_protection_address: '5/1/5' operation_mode_night_address: '5/1/6' operation_mode_comfort_address: '5/1/7' operation_mode_state_address: '5/1/8' ``` If your device doesn't support setpoint_shift calculations (i.e., if you don't provide a `setpoint_shift_address` value) please set the `min_temp` and `max_temp` attributes of the climate device to avoid issues with exceeding valid temperature values in the frontend. Please do also make sure to add the `target_temperature_address` to the configuration in this case.: ```yaml # Example configuration.yaml entry knx: climate: - name: HASS-Kitchen.Temperature temperature_address: '5/1/2' target_temperature_address: '5/1/4' target_temperature_state_address: '5/1/1' operation_mode_frost_protection_address: '5/1/5' operation_mode_night_address: '5/1/6' operation_mode_comfort_address: '5/1/7' operation_mode_state_address: '5/1/8' operation_mode_standby_address: '5/1/9' min_temp: 7.0 max_temp: 32.0 ``` `setpoint_shift_mode` allows the two following DPTs to be used: - DPT6002 (for 1 byte signed integer) - DPT9002 (for 2 byte float) Example: ```yaml # Example configuration.yaml entry knx: climate: - name: HASS-Kitchen.Temperature temperature_address: '5/1/1' setpoint_shift_address: '5/1/2' setpoint_shift_state_address: '5/1/3' setpoint_shift_mode: 'DPT9002' target_temperature_state_address: '5/1/4' operation_mode_address: '5/1/5' operation_mode_state_address: '5/1/6' ``` `operation_mode_frost_protection_address` / `operation_mode_night_address` / `operation_mode_comfort_address` / `operation_mode_standby_address` are not necessary if `operation_mode_address` is specified. If the actor doesn't support explicit state communication objects the *_state_address can be configured with the same group address as the writeable *_address. The Read-Flag for the *_state_address communication object has to be set in ETS to support initial reading e.g., when starting Home Assistant. The following values are valid for the `heat_cool_address` and the `heat_cool_state_address`: - 0 (cooling) - 1 (heating) The following values are valid for the `hvac_mode` attribute: - Off (maps internally to HVAC_MODE_OFF within Home Assistant) - Auto (maps internally to HVAC_MODE_AUTO within Home Assistant) - Heat (maps internally to HVAC_MDOE_HEAT within Home Assistant) - Cool (maps internally to HVAC_MDOE_COOL within Home Assistant) - Fan only (maps internally to HVAC_MODE_FAN_ONLY within Home Assistant) - Dry (maps internally to HVAC_MODE_DRY within Home Assistant) The following presets are valid for the `preset_mode` attribute: - Auto (maps internally to PRESET_NONE within Home Assistant) - Comfort (maps internally to PRESET_COMFORT within Home Assistant) - Standby (maps internally to PRESET_AWAY within Home Assistant) - Night (maps internally to PRESET_SLEEP within Home Assistant) - Frost Protection (maps internally to PRESET_ECO within Home Assistant) {% configuration %} name: description: A name for this device used within Home Assistant. required: false default: KNX Climate type: string temperature_address: description: KNX group address for reading current room temperature from KNX bus. *DPT 9.001* required: true type: string temperature_step: description: Defines the step size in Kelvin for each step of setpoint_shift. required: false type: float default: 0.1 target_temperature_address: description: KNX group address for setting target temperature. *DPT 9.001* required: false type: string target_temperature_state_address: description: KNX group address for reading current target temperature from KNX bus. *DPT 9.001* required: true type: string setpoint_shift_address: description: KNX address for setpoint_shift. *DPT 6.010 or DPT 9.002 based on setpoint_shift_mode* required: false type: string setpoint_shift_state_address: description: KNX address for reading setpoint_shift. *DPT 6.010 or DPT 9.002 based on setpoint_shift_mode* required: false type: string setpoint_shift_mode: description: Defines the internal device DPT used. Either 'DPT6010' or 'DPT9002'. required: false default: 0.5 type: string default: DPT6010 setpoint_shift_min: description: Minimum value of setpoint shift. required: false default: -6 type: float setpoint_shift_max: description: Maximum value of setpoint shift. required: false default: 6 type: float operation_mode_address: description: KNX address for setting operation mode (Frost protection/night/comfort). *DPT 20.102* required: false type: string operation_mode_state_address: description: KNX address for reading operation mode. *DPT 20.102* required: false type: string controller_status_address: description: KNX address for HVAC controller status (in accordance with KNX AN 097/07 rev 3). required: false type: string controller_status_state_address: description: KNX address for reading HVAC controller status. required: false type: string controller_mode_address: description: KNX address for setting HVAC controller modes. *DPT 20.105* required: false type: string controller_mode_state_address: description: KNX address for reading HVAC Control Mode. *DPT 20.105* required: false type: string heat_cool_address: description: KNX address for switching between heat/cool mode. *DPT 1.100* required: false type: string heat_cool_state_address: description: KNX address for reading heat/cool mode. *DPT 1.100* required: false type: string operation_mode_frost_protection_address: description: KNX address for switching on/off frost/heat protection mode. *DPT 1* required: false type: string operation_mode_night_address: description: KNX address for switching on/off night mode. *DPT 1* required: false type: string operation_mode_comfort_address: description: KNX address for switching on/off comfort mode. *DPT 1* required: false type: string operation_mode_standby_address: description: KNX address for switching on/off standby mode. *DPT 1* required: false type: string operation_modes: description: Overrides the supported operation modes. Provide the supported `preset_mode` values for your device. required: false type: list controller_modes: description: Overrides the supported controller modes. Provide the supported `hvac_mode` values for your device. required: false type: list on_off_address: description: KNX address for switching the climate device on/off. *DPT 1* required: false type: string on_off_invert: description: Value for switching the climate device on/off is inverted. required: false default: false type: boolean on_off_state_address: description: KNX address for gathering the current state (on/off) of the climate device. *DPT 1* required: false type: string min_temp: description: Override the minimum temperature. required: false type: float max_temp: description: Override the maximum temperature. required: false type: float {% endconfiguration %} ## Cover The `knx` cover platform is used as an interface to KNX covers. To use your KNX covers in your installation, add the following lines to your top level [KNX Integration](/integrations/knx) configuration key in `configuration.yaml`: ```yaml # Example configuration.yaml entry knx: cover: - name: "Kitchen.Shutter" move_long_address: '3/0/0' move_short_address: '3/0/1' stop_address: '3/0/4' position_address: '3/0/3' position_state_address: '3/0/2' travelling_time_down: 51 travelling_time_up: 61 ``` {% configuration %} name: description: A name for this device used within Home Assistant. required: false default: KNX Cover type: string move_long_address: description: KNX group address for moving the cover full up or down. *DPT 1* required: false type: string move_short_address: description: KNX group address for moving the cover short time up or down. *DPT 1* required: false type: string stop_address: description: KNX group address for stopping the current movement from the cover. *DPT 1* required: false type: string position_address: description: KNX group address for moving the cover to the dedicated position. *DPT 5.001* required: false type: string position_state_address: description: Separate KNX group address for requesting the current position of the cover. *DPT 5.001* required: false type: string angle_address: description: KNX group address for moving the cover to the dedicated angle. *DPT 5.001* required: false type: string angle_state_address: description: Separate KNX group address for requesting the current angle of cover. *DPT 5.001* required: false type: string travelling_time_down: description: Time cover needs to travel down in seconds. Needed to calculate the intermediate positions of cover while traveling. required: false default: 25 type: integer travelling_time_up: description: Time cover needs to travel up in seconds. Needed to calculate the intermediate positions of cover while traveling. required: false default: 25 type: integer invert_position: description: Set this to true if your actuator report fully closed as 0% in KNX. required: false default: false type: boolean invert_angle: description: Set this to true if your actuator reports tilt fully closed as 0% in KNX. required: false default: false type: boolean device_class: description: Sets the [class of the device](/integrations/cover/), changing the device state and icon that is displayed on the frontend. required: false type: string {% endconfiguration %} ## Light The `knx light` integration is used as an interface to control KNX actuators for lighting applications such as: - switching actuators - dimming actuators - LED controllers - DALI gateways ### Configuration To use your KNX light in your installation, add the following lines to your top level [KNX Integration](/integrations/knx) configuration key in `configuration.yaml`: ```yaml # Example configuration.yaml entry knx: light: - name: 'kitchen' address: '1/0/9' ``` {% configuration %} address: description: KNX group address for switching the light on and off. *DPT 1.001* required: true type: string state_address: description: KNX group address for retrieving the switch state of the light. *DPT 1.001* required: false type: string name: description: A name for this device used within Home Assistant. required: false type: string brightness_address: description: KNX group address for setting the brightness of the light in percent (absolute dimming). *DPT 5.001* required: false type: string brightness_state_address: description: KNX group address for retrieving the brightness of the light in percent. *DPT 5.001* required: false type: string color_address: description: KNX group address for setting the RGB color of the light. *DPT 232.600* required: false type: string color_state_address: description: KNX group address for retrieving the RGB color of the light. *DPT 232.600* required: false type: string rgbw_address: description: KNX group address for setting the RGBW color of the light. *DPT 251.600* required: false type: string rgbw_state_address: description: KNX group address for retrieving the RGBW color of the light. *DPT 251.600* required: false type: string color_temperature_address: description: KNX group address for setting the color temperature of the light. *DPT 5.001 or 7.600 based on color_temperature_mode* required: false type: string color_temperature_state_address: description: KNX group address for retrieving the color temperature of the light. *DPT 5.001 or 7.600 based on color_temperature_mode* required: false type: string color_temperature_mode: description: Color temperature group address data type. `absolute` color temperature in Kelvin. *color_temperature_address -> DPT 7.600*. `relative` color temperature in percent cold white (0% warmest; 100% coldest). *color_temperature_address -> DPT 5.001* required: false type: string default: absolute min_kelvin: description: Warmest possible color temperature in Kelvin. (Used in combination with *color_temperature_address*) required: false type: integer default: 2700 max_kelvin: description: Coldest possible color temperature in Kelvin. (Used in combination with *color_temperature_address*) required: false type: integer default: 6000 {% endconfiguration %} Many KNX devices can change their state internally without a message to the switch address on the KNX bus, e.g., if you configure a scene or a timer on a channel. The optional `state_address` can be used to inform Home Assistant about these state changes. If a KNX message is seen on the bus addressed to the given `state_address` (in most cases from the light actuator), it will overwrite the state of the switch object. For switching/light actuators that are only controlled by a single group address and don't have dedicated state communication objects you can set `state_address` to the same value as `address`. *Note on tunable white:* Home Assistant uses Mireds as the unit for color temperature, whereas KNX typically uses Kelvin. The Kelvin/Mireds relationship is reciprocal, not linear, therefore the color temperature pickers (sliders) in Home Assistant may not align with ones of KNX visualizations. This is the expected behavior. ## Extended configuration example ```yaml knx: light: # dimmable light - name: Bedroom-Light-1 address: '1/0/9' state_address: '1/1/9' brightness_address: '1/2/9' brightness_state_address: '1/3/9' # # RGB light - name: Bathroom-Light-1 address: '1/0/9' state_address: '1/1/9' brightness_address: '1/2/9' brightness_state_address: '1/3/9' color_address: '1/4/9' color_state_address: '1/5/9' # # tunable white light - name: Office-Light-1 address: '1/0/21' state_address: '1/1/21' brightness_address: '1/2/21' brightness_state_address: '1/3/21' color_temperature_address: '1/4/21' color_temperature_state_address: '1/5/21' color_temperature_mode: absolute min_kelvin: 2550 max_kelvin: 6200 # # actuator without dedicated state communication object - name: Cellar-Light-1 address: '1/0/5' state_address: '1/0/5' ``` ## Notify The `knx` notify platform allows you to send notifications to [KNX](https://www.knx.org/) devices. ### Configuration To use your KNX switch in your installation, add the following lines to your top level [KNX Integration](/integrations/knx) configuration key in `configuration.yaml`: ```yaml knx: notify: - name: Alarm address: '5/1/10' ``` {% configuration %} address: description: KNX group address of the notification. *DPT 16.000* required: true type: string name: description: A name for this device used within Home Assistant. required: false type: string {% endconfiguration %} The `knx` scenes platform allows you to trigger [KNX](https://www.knx.org/) scenes. ## Scene ### Configuration To use your KNX scene in your installation, add the following lines to your top level [KNX Integration](/integrations/knx) configuration key in `configuration.yaml`: ```yaml # Example configuration.yaml entry knx: scene: - name: Romantic address: 8/8/8 scene_number: 23 ``` {% configuration %} address: description: KNX group address for the scene. *DPT 17.001* required: true type: string scene_number: description: KNX scene number to be activated. ( 1 ... 64 ) required: true type: integer name: description: A name for this device used within Home Assistant. required: false type: string {% endconfiguration %} ## Sensor The `knx` sensor platform allows you to monitor [KNX](https://www.knx.org/) sensors. Sensors are read-only. To write to the knx-bus configure an exposure [KNX Integration - Expose](/integrations/knx/#exposing-sensor-values-or-time-to-knx-bus). ### Configuration To use your KNX sensor in your installation, add the following lines to your top level [KNX Integration](/integrations/knx) configuration key in `configuration.yaml`: ```yaml # Example configuration.yaml entry knx: sensor: - name: Heating.Valve1 state_address: '2/0/0' ``` In order to actively read the sensor data from the bus all 30 minutes you can add the following lines to your `configuration.yaml`: ```yaml # Example configuration.yaml entry knx: sensor: - name: Heating.Valve1 state_address: '2/0/0' sync_state: every 30 ``` {% configuration %} state_address: description: KNX group address of the sensor. required: true type: string name: description: A name for this device used within Home Assistant. required: false type: string sync_state: description: Actively read the value from the bus. If `False` no GroupValueRead telegrams will be sent to the bus. `sync_state` can be set to `init` to just initialize state on startup, `expire ` to read the state from the KNX bus when no telegram was received for \ or `every ` to update it regularly every \. Maximum value for \ is 1440. If just a number is configured "expire"-behaviour is used. Defaults to `True` which is interpreted as "expire 60". required: false type: [boolean, string, integer] default: True type: description: A type from the following table must be defined. The DPT of the group address should match the expected KNX DPT to be parsed correctly. required: true type: string always_callback: description: Defines if telegrams with equal payload as the previously received telegram should trigger a state update within Home Assistant. required: false type: boolean default: False {% endconfiguration %} | KNX DPT | type | size in byte | range | unit | |--------:|-------------------------------|-------------:|:--------------------------:|----------------| | 5.001 | percent | 1 | 0 ... 100 | % | | 5.003 | angle | 1 | 0 ... 360 | ° | | 5.004 | percentU8 | 1 | 0 ... 255 | % | | 5.010 | pulse | 1 | 0 ... 255 | | | 5.010 | 1byte_unsigned | 1 | 0 ... 255 | | | 6.001 | percentV8 | 1 | -128 ... 127 | % | | 6.010 | counter_pulses | 1 | -128 ... 127 | counter pulses | | 7.001 | 2byte_unsigned | 2 | 0 ... 65535 | pulses | | 7.002 | time_period_msec | 2 | 0 ... 65535 | ms | | 7.003 | time_period_10msec | 2 | 0 ... 65535 | ms | | 7.004 | time_period_100msec | 2 | 0 ... 65535 | ms | | 7.005 | time_period_sec | 2 | 0 ... 65535 | s | | 7.006 | time_period_min | 2 | 0 ... 65535 | min | | 7.007 | time_period_hrs | 2 | 0 ... 65535 | h | | 7.011 | length_mm | 2 | 0 ... 65535 | mm | | 7.012 | current | 2 | 0 ... 65535 | mA | | 7.013 | brightness | 2 | 0 ... 65535 | lx | | 7.600 | color_temperature | 2 | 0 ... 65535 | K | | 8.001 | 2byte_signed | 2 | -32768 ... 32767 | pulses | | 8.002 | delta_time_ms | 2 | -32768 ... 32767 | ms | | 8.005 | delta_time_sec | 2 | -32768 ... 32767 | s | | 8.006 | delta_time_min | 2 | -32768 ... 32767 | min | | 8.007 | delta_time_hrs | 2 | -32768 ... 32767 | h | | 8.010 | percentV16 | 2 | -32768 ... 32767 | % | | 8.011 | rotation_angle | 2 | -32768 ... 32767 | ° | | 9.* | enthalpy | 2 | -671088.64 ... 670760.96 | H | | 9.001 | temperature | 2 | -273 ... 670760 | °C | | 9.002 | temperature_difference_2byte | 2 | -670760 ... 670760 | K | | 9.003 | temperature_a | 2 | -670760 ... 670760 | K/h | | 9.004 | illuminance | 2 | 0 ... 670760 | lx | | 9.005 | wind_speed_ms | 2 | 0 ... 670760 | m/s | | 9.006 | pressure_2byte | 2 | 0 ... 670760 | Pa | | 9.007 | humidity | 2 | 0 ... 670760 | % | | 9.008 | ppm | 2 | -671088.64 ... 670760.96 | ppm | | 9.010 | time_1 | 2 | -670760 ... 670760 | s | | 9.011 | time_2 | 2 | -670760 ... 670760 | ms | | 9.020 | voltage | 2 | -671088.64 ... 670760.96 | mV | | 9.022 | power_density | 2 | -671088.64 ... 670760.96 | W/m² | | 9.023 | kelvin_per_percent | 2 | -671088.64 ... 670760.96 | K/% | | 9.024 | power_2byte | 2 | -671088.64 ... 670760.96 | kW | | 9.025 | volume_flow | 2 | -671088.64 ... 670760.96 | l/h | | 9.026 | rain_amount | 2 | -671088.64 ... 670760.96 | l/m² | | 9.027 | temperature_f | 2 | -459.6 ... 670760 | °F | | 9.028 | wind_speed_kmh | 2 | 0 ... 670760 | km/h | | 12.*** | 4byte_unsigned | 4 | 0 ... 4294967295 | | | 13.*** | 4byte_signed | 4 | -2147483648 ... 2147483647 | | | 13.002 | flow_rate_m3h | 4 | -2147483648 ... 2147483647 | m³/h | | 13.010 | active_energy | 4 | -2147483648 ... 2147483647 | Wh | | 13.011 | apparant_energy | 4 | -2147483648 ... 2147483647 | VAh | | 13.012 | reactive_energy | 4 | -2147483648 ... 2147483647 | VARh | | 13.013 | active_energy_kwh | 4 | -2147483648 ... 2147483647 | kWh | | 13.014 | apparant_energy_kvah | 4 | -2147483648 ... 2147483647 | kVAh | | 13.015 | reactive_energy_kvarh | 4 | -2147483648 ... 2147483647 | kVARh | | 13.100 | long_delta_timesec | 4 | -2147483648 ... 2147483647 | s | | 14.000 | acceleration | 4 | | m/s² | | 14.*** | 4byte_float | 4 | | | | 14.001 | acceleration_angular | 4 | | rad/s² | | 14.002 | activation_energy | 4 | | J/mol | | 14.003 | activity | 4 | | s⁻¹ | | 14.004 | mol | 4 | | mol | | 14.005 | amplitude | 4 | | | | 14.006 | angle_rad | 4 | | rad | | 14.007 | angle_deg | 4 | | ° | | 14.008 | angular_momentum | 4 | | J s | | 14.009 | angular_velocity | 4 | | rad/s | | 14.010 | area | 4 | | m² | | 14.011 | capacitance | 4 | | F | | 14.012 | charge_density_surface | 4 | | C/m² | | 14.013 | charge_density_volume | 4 | | C/m³ | | 14.014 | compressibility | 4 | | m²/N | | 14.015 | conductance | 4 | | S | | 14.016 | electrical_conductivity | 4 | | S/m | | 14.017 | density | 4 | | kg/m³ | | 14.018 | electric_charge | 4 | | C | | 14.019 | electric_current | 4 | | A | | 14.020 | electric_current_density | 4 | | A/m² | | 14.021 | electric_dipole_moment | 4 | | C m | | 14.022 | electric_displacement | 4 | | C/m² | | 14.023 | electric_field_strength | 4 | | V/m | | 14.024 | electric_flux | 4 | | c | | 14.025 | electric_flux_density | 4 | | C/m² | | 14.026 | electric_polarization | 4 | | C/m² | | 14.027 | electric_potential | 4 | | V | | 14.028 | electric_potential_difference | 4 | | V | | 14.029 | electromagnetic_moment | 4 | | A m² | | 14.030 | electromotive_force | 4 | | V | | 14.031 | energy | 4 | | J | | 14.032 | force | 4 | | N | | 14.033 | frequency | 4 | | Hz | | 14.034 | angular_frequency | 4 | | rad/s | | 14.035 | heatcapacity | 4 | | J/K | | 14.036 | heatflowrate | 4 | | W | | 14.037 | heat_quantity | 4 | | J | | 14.038 | impedance | 4 | | Ω | | 14.039 | length | 4 | | m | | 14.040 | light_quantity | 4 | | lm s | | 14.041 | luminance | 4 | | cd/m² | | 14.042 | luminous_flux | 4 | | lm | | 14.043 | luminous_intensity | 4 | | cd | | 14.044 | magnetic_field_strength | 4 | | A/m | | 14.045 | magnetic_flux | 4 | | Wb | | 14.046 | magnetic_flux_density | 4 | | T | | 14.047 | magnetic_moment | 4 | | A m² | | 14.048 | magnetic_polarization | 4 | | T | | 14.049 | magnetization | 4 | | A/m | | 14.050 | magnetomotive_force | 4 | | A | | 14.051 | mass | 4 | | kg | | 14.052 | mass_flux | 4 | | kg/s | | 14.053 | momentum | 4 | | N/s | | 14.054 | phaseanglerad | 4 | | rad | | 14.055 | phaseangledeg | 4 | | ° | | 14.056 | power | 4 | | W | | 14.057 | powerfactor | 4 | | cosΦ | | 14.058 | pressure | 4 | | Pa | | 14.059 | reactance | 4 | | Ω | | 14.060 | resistance | 4 | | Ω | | 14.061 | resistivity | 4 | | Ω m | | 14.062 | self_inductance | 4 | | H | | 14.063 | solid_angle | 4 | | sr | | 14.064 | sound_intensity | 4 | | W/m² | | 14.065 | speed | 4 | | m/s | | 14.066 | stress | 4 | | Pa | | 14.067 | surface_tension | 4 | | N/m | | 14.068 | common_temperature | 4 | | °C | | 14.069 | absolute_temperature | 4 | | K | | 14.070 | temperature_difference | 4 | | K | | 14.071 | thermal_capacity | 4 | | J/K | | 14.072 | thermal_conductivity | 4 | | W/mK | | 14.073 | thermoelectric_power | 4 | | V/K | | 14.074 | time_seconds | 4 | | s | | 14.075 | torque | 4 | | N m | | 14.076 | volume | 4 | | m³ | | 14.077 | volume_flux | 4 | | m³/s | | 14.078 | weight | 4 | | N | | 14.079 | work | 4 | | J | | 16.000 | string | 14 | | | | 17.001 | scene_number | 1 | 1 ... 64 | | ### Full example ```yaml # Example configuration.yaml entry knx: sensor: - name: Heating.Valve1 state_address: '2/0/0' sync_state: init type: 'percent' - name: Kitchen.Temperature state_address: '6/2/1' sync_state: every 60 type: 'temperature' ``` ## Switch The `knx` switch platform is used as an interface to switching actuators. ### Configuration To use your KNX switch in your installation, add the following lines to your top level [KNX Integration](/integrations/knx) configuration key in `configuration.yaml`: ```yaml knx: switch: - name: Kitchen.Coffee address: '1/1/6' ``` {% configuration %} address: description: KNX group address for switching the switch on/off. *DPT 1* required: true type: string name: description: A name for this device used within Home Assistant. required: false default: KNX Switch type: string state_address: description: Separate KNX group address for retrieving the switch state. *DPT 1* required: false type: string invert: description: Invert the telegrams payload before processing or sending. required: false type: boolean default: False {% endconfiguration %} Some KNX devices can change their state internally without any messages on the KNX bus, e.g., if you configure a timer on a channel. The optional `state_address` can be used to inform Home Assistant about these state changes. If a KNX message is seen on the bus addressed to the given state address, this will overwrite the state of the switch object. For switching actuators that are only controlled by a single group address and can't change their state internally, you don't have to configure the state address. ## Weather The `knx` weather platform is used as an interface to KNX weather stations. To use your KNX weather station in your installation, add the following lines to your top level [KNX Integration](/integrations/knx) configuration key in `configuration.yaml`: ```yaml # Example configuration.yaml entry knx: weather: - name: "home" address_temperature: "7/0/0" address_brightness_south: "7/0/1" address_brightness_west: "7/0/2" address_brightness_east: "7/0/3" address_brightness_north: "7/0/11" address_wind_speed: "7/0/4" address_rain_alarm: "7/0/5" address_frost_alarm: "7/0/6" address_wind_alarm: "7/0/7" address_day_night: "7/0/8" address_air_pressure: "7/0/9" address_humidity: "7/0/10" expose_sensors: False sync_state: True ``` {% configuration %} name: description: A name for this device used within Home Assistant. required: false default: KNX Weather type: string address_temperature: description: KNX group address for reading current outside temperature from KNX bus. *DPT 9.001* required: true type: string address_brightness_south: description: KNX group address for reading current brightness to south coordinate from KNX bus. *DPT 9.004* required: false type: string address_brightness_west: description: KNX group address for reading current brightness to west coordinate from KNX bus. *DPT 9.004* required: false type: string address_brightness_east: description: KNX group address for reading current brightness to east coordinate from KNX bus. *DPT 9.004* required: false type: string address_brightness_north: description: KNX group address for reading current brightness to north coordinate from KNX bus. *DPT 9.004* required: false type: string address_wind_speed: description: KNX group address for reading current wind speed from KNX bus. *DPT 9.005* required: false type: string address_rain_alarm: description: KNX group address for reading if rain alarm is on/off. required: false type: string address_frost_alarm: description: KNX group address for reading if frost alarm is on/off. required: false type: string address_wind_alarm: description: KNX group address for reading if wind alarm is on/off. required: false type: string address_day_night: description: KNX group address for reading if it's day/night. required: false type: string address_air_pressure: description: KNX address reading current air pressure. *DPT 9.006* required: false type: string address_humidity: description: KNX address for reading current humidity. *DPT 9.007* required: false type: string expose_sensors: description: If true, exposes all sensor values as dedicated sensors to HA. required: false type: boolean default: False sync_state: description: Actively read the value from the bus. If `False` no GroupValueRead telegrams will be sent to the bus. required: false type: boolean default: True {% endconfiguration %}