title: DSMR Slimme Meter
description: Instructions on how to integrate DSMR Smartmeter within Home Assistant.
logo: netbeheernederland.jpg
ha_category:
- Energy
ha_release: 0.34
ha_iot_class: Local Push
ha_domain: dsmr
ha_codeowners:
- '@Robbie1221'
---
A sensor platform for Dutch Smart Meters which comply to DSMR (Dutch Smart Meter Requirements), also known as 'Slimme meter' or 'P1 poort'.
- Currently support DSMR V2.2, V3, V4, V5 and V5 Belgian through the [dsmr_parser](https://github.com/ndokter/dsmr_parser) module by Nigel Dokter.
- For official information about DSMR refer to: [DSMR Document](https://www.netbeheernederland.nl/dossiers/slimme-meter-15)
- For official information about the P1 port refer to: [P1 Companion Standard](https://www.netbeheernederland.nl/_upload/Files/Slimme_meter_15_a727fce1f1.pdf)
- For unofficial hardware connection examples refer to: [Domoticx](http://domoticx.com/p1-poort-slimme-meter-hardware/)
This integration is known to work for:
- Iskra ME382 / MT382 (DSMR 2.2)
- ISKRA AM550 (DSMR 5.0)
- Landis+Gyr E350 (DMSR 4)
- Landis+Gyr ZCF110 / ZM F110 (DSMR 4.2)
- Kaifa E0026
- Kamstrup 382JxC (DSMR 2.2)
- Sagemcom XS210 ESMR5
USB serial converters:
- Cheap (Banggood/ebay) Generic PL2303
- [Smartmeter Webshop](https://sites.google.com/site/nta8130p1smartmeter/webshop)
- [SOS Solutions](https://www.sossolutions.nl/slimme-meter-kabel)
- [AliExpress](https://nl.aliexpress.com/item/32945187155.html)
Serial to network proxies:
- [ser2net](http://ser2net.sourceforge.net)
DIY solutions (ESP8266 based):
- [esp8266_p1meter (fliphess)](https://github.com/fliphess/esp8266_p1meter)
```yaml
# Example configuration.yaml entry
sensor:
- platform: dsmr
```
{% configuration %}
port:
description: "Serial port to which Smartmeter is connected via USB. For remote (i.e., ser2net) connections, use TCP port number to connect to (i.e., 2001)."
required: false
type: string
default: "/dev/ttyUSB0"
host:
description: "Host to which Smartmeter is connected via serial or USB, see **port**. For remote connections, use IP address of host to connect to (i.e., 192.168.1.13)."
required: false
type: string
dsmr_version:
description: "Version of DSMR used by meter. Choices: `2.2`, `4`, `5`, `5B` (For Belgian Meter)."
required: false
type: string
default: "2.2"
reconnect_interval:
description: The reconnect interval in seconds when the connection is lost with the Smartmeter.
required: false
type: integer
default: 30
precision:
description: Defines the precision of the calculated values, through the argument of round().
required: false
type: integer
default: 3
{% endconfiguration %}
Full configuration examples can be found below:
```yaml
# Example configuration.yaml entry for USB/serial connected Smartmeter
sensor:
- platform: dsmr
port: /dev/ttyUSB1
dsmr_version: 5
group:
meter_readings:
name: Meter readings
entities:
- sensor.energy_consumption_tarif_1
- sensor.energy_consumption_tarif_2
- sensor.energy_production_tarif_1
- sensor.energy_production_tarif_2
- sensor.gas_consumption
```
```yaml
# Example configuration.yaml entry for remote (TCP/IP, i.e., via ser2net) connection to host which is connected to Smartmeter
sensor:
- platform: dsmr
host: 192.168.1.13
port: 2001
dsmr_version: 5
group:
meter_readings:
name: Meter readings
entities:
- sensor.energy_consumption_tarif_1
- sensor.energy_consumption_tarif_2
- sensor.energy_production_tarif_1
- sensor.energy_production_tarif_2
- sensor.gas_consumption
```
Optional configuration example for ser2net:
```sh
# Example /etc/ser2net.conf for proxying USB/serial connections to DSMRv4 smart meters
2001:raw:600:/dev/ttyUSB0:115200 NONE 1STOPBIT 8DATABITS XONXOFF LOCAL -RTSCTS
```
or
```sh
# Example /etc/ser2net.conf for proxying USB/serial connections to DSMRv2.2 smart meters
2001:raw:600:/dev/ttyUSB0:9600 EVEN 1STOPBIT 7DATABITS XONXOFF LOCAL -RTSCTS
```
Docker users have to allow Docker access to the device by adding `--device /dev/ttyUSB21:/dev/ttyUSB21` to the run command:
```hass
$ docker run --device /dev/ttyUSB0:/dev/ttyUSB0 -d --name="home-assistant" -v /home/USERNAME/hass:/config -v /etc/localtime:/etc/localtime:ro --net=host homeassistant/home-assistant
```
### Options
To configure options for DSMR integration go to **Configuration** >> **Integrations** and press **Options** on the DSMR card.
#### Time between updates
Typically the smart meter sends new data every 5-10 seconds. This value defines the minimum time between entity updates in seconds. Setting this value to 0 will update entities each time data is received from the smart meter.
Reducing the default time between updates will increase the amount of events generated and can potentially flood the system with events.
### Technical overview
DSMR is a standard to which Dutch smartmeters must comply. It specifies that the smartmeter must send out a 'telegram' every 10 seconds (every second for DSMR 5.0 devices) over a serial port.
The contents of this telegram differ between version but they generally consist of lines with 'obis' (Object Identification System, a numerical ID for a value) followed with the value and unit.
This module sets up an asynchronous reading loop using the `dsmr_parser` module which waits for a complete telegram, parser it and puts it on an async queue as a dictionary of `obis`/object mapping. The numeric value and unit of each value can be read from the objects attributes. Because the `obis` are know for each DSMR version the Entities for this integration are create during bootstrap.
Another loop (DSMR class) is setup which reads the telegram queue, stores/caches the latest telegram and notifies the Entities that the telegram has been updated.