--- title: Switcher description: Integrate Switcher devices. ha_category: - Switch ha_release: 0.93 ha_iot_class: Local Push ha_codeowners: - '@tomerfi' - '@thecode' ha_domain: switcher_kis ha_platforms: - sensor - switch ha_config_flow: true --- This `Switcher` integration allows you to control your [Switcher Devices](https://www.switcher.co.il/). Supported devices: - Switcher Power Plug - Switcher Touch (from firmware 1.51) - Switcher V2 (Espressif chipset - from firmware 3.21) - Switcher V2 (Qualcomm chipset - from firmware 72.32) - Switcher V4 If you completed the integration setup but are still unable to control the device, please make sure your device's firmware is up-to-date. {% include integrations/config_flow.md %} ## Sensors | Sensor Name | Description | Example | | ------------------- | ------------------------------------------------------ | ----------------- | | `Auto Shutdown` | The auto shutdown time limit configured on the device | 01:30:00 | | `Remaining Time` | Time remaining to shutdown (auto or timer) | 01:29:41 | | `Electric Current` | The electric current in amps | 12.5 A | | `Power Consumption` | The power consumption in watts | 2756 W | ## Services ### Service: `switcher_kis.set_auto_off` You can use the `switcher_kis.set_auto_off` service to set the auto-off configuration setting for the device. Meaning the device will turn itself off when reaching the auto-off configuration limit. | Service Field | Mandatory | Description | Example | | ------------- | --------- | -------------------------------------------------------------------------------------- | -------------------------- | | `entity_id` | Yes | Name of the entity id associated with the integration, used for permission validation | switch.switcher_kis_boiler | | `auto_off` | Yes | Time period string containing hours and minutes | "02:30" | ### Service: `switcher_kis.turn_on_with_timer` You can use the `switcher_kis.turn_on_with_timer` service to turn on the switcher device with timer. Meaning the device will turn itself off when timer ends. Note: This does not affect the auto off timer. | Service Field | Mandatory | Description | Example | | ------------- | --------- | -------------------------------------------------------------------------------------- | -------------------------- | | `entity_id` | Yes | Name of the entity id associated with the integration, used for permission validation | switch.switcher_kis_boiler | | `timer_minutes` | Yes | Integer containing timer minutes (valid range 1 to 150) | 90 |