--- layout: page title: NUT Sensor description: "Instructions on how to set up NUT sensors within Home Assistant." date: 2016-11-23 sidebar: true comments: false sharing: true footer: true logo: nut.png ha_category: System Monitor ha_version: 0.34 --- The `nut` sensor platform allows you to monitor a UPS (battery backup) by using data from a [NUT](http://networkupstools.org/) (Network UPS Tools) server. To use this sensor platform, you need to add the following to your `configuration.yaml` file: ```yaml # Example configuration.yaml entry sensor: - platform: nut resources: - ups.load - ups.realpower.nominal - input.voltage - battery.runtime ``` Configuration variables: - **name** (*Optional*): Name prefix for defined sensors. Defaults to 'NUT UPS'. - **host** (*Optional*): The host name or address of the device that is running NUT. Defaults to localhost. - **port** (*Optional*): The port number. Defaults to 3493. - **alias** (*Optional*): Name of the ups on the NUT server. Will default to the first UPS name listed. - **username** (*Optional*): Username to login to the NUT server. Default is none. - **password** (*Optional*): Password to login to the NUT server. Default is none. - **resources** array (*Required*): Contains all entries to display. ### {% linkable_title Example %} Given the following example output from NUT (Your variables may differ): ```yaml 'ups.timer.reboot': '0', 'battery.voltage': '27.0', 'ups.firmware.aux': 'L3 -P ', 'ups.mfr': 'American Power Conversion', 'battery.runtime.low': '120', 'ups.delay.shutdown': '20', 'ups.load': '19', 'ups.realpower.nominal': '600', 'battery.charge.warning': '50', 'battery.charge.low': '10', 'ups.vendorid': '051d', 'ups.timer.shutdown': '-1', 'ups.test.result': 'No test initiated', 'ups.firmware': '868.L3 -P.D', 'battery.mfr.date': '2015/05/08', 'ups.serial': '3B1519X19994 ', 'ups.productid': '0002', 'battery.runtime': '2552', 'battery.date': '2001/09/25', 'battery.voltage.nominal': '24.0', 'battery.type': 'PbAc', 'ups.mfr.date': '2015/05/08', 'ups.status': 'OL', 'ups.model': 'Back-UPS RS1000G', 'ups.beeper.status': 'disabled', 'battery.charge': '100', 'input.sensitivity': 'medium', 'input.transfer.low': '88' 'input.transfer.high': '147', 'input.voltage': '121.0', 'input.voltage.nominal': '120', 'input.transfer.reason': 'input voltage out of range', ``` Use the values from the left hand column. Support is included for most values with 'ups', 'battery', and 'input' prefixes. ```yaml sensor: - platform: nut name: UPS Name host: 192.168.11.5 port: 3493 alias: ups_name username: user password: pass resources: - ups.load - ups.realpower.nominal - input.voltage - battery.runtime ```