--- layout: page title: "Danfoss Air" description: "How to integrate Danfoss Air HRV in Home Assistant." date: 2019-01-14 20:00 sidebar: true comments: false sharing: true footer: true ha_category: - Climate - Binary Sensor - Sensor - Switch ha_release: 0.87 logo: danfoss_air.png ha_iot_class: Local Polling redirect_from: - /components/binary_sensor.danfoss_air/ - /components/sensor.danfoss_air/ - /components/switch.danfoss_air/ --- The `danfoss_air` component allows you to access information from your Danfoss Air HRV unit. *Note*: Danfoss Air CCM only accepts one TCP connection at a time. Due to this the component will not work while you have the HRV PC-Tool open. There is currently support for the following device types within Home Assistant: - [Binary sensor](#binary-sensor) - [Sensor](#sensor) - [Switch](#switch) ```yaml # Example configuration.yaml entry danfoss_air: host: IP_ADDRESS_OF_CCM ``` {% configuration %} host: description: Danfoss Air CCM IP. required: true type: string {% endconfiguration %} ## {% linkable_title Binary sensor %} The following binary sensor is supported. - **Bypass active:** Indicator if heat recovery is currrently bypassed. ## {% linkable_title Sensor %} The following sensors are supported. - **Outdoor temperature:** Outdoor air temperature. - **Supply temperature:** Air temperature of the air supplied to the house. - **Extract temperature:** Air temperature of the air extracted from the house. - **Exhaust temperature:** Exhausted air temperature. - **Remaining filter lifetime:** Reamining filter lifetime measured in percent. ## {% linkable_title Switch %} The following switches are supported. - **Boost:** Switch to manually activate boost.