--- layout: page title: "Min/max Sensor" description: "Instructions on how to integrate min/max sensors into Home Assistant." date: 2016-10-13 12:00 sidebar: true comments: false sharing: true footer: true logo: home-assistant.png ha_category: Utility ha_iot_class: Local Polling ha_release: 0.31 ha_qa_scale: internal redirect_from: - /components/sensor.min_max/ --- The `min_max` sensor platform consumes the state from other sensors to determine the minimum, maximum, latest (last) and the mean of the collected states. The sensor will always show you the lowest/highest/latest value which was received from all monitored sensors. If you have spikes in your values, it's recommended to filter/equalize your values with a [statistics sensor](/components/sensor.statistics/) first. This sensor is an alternative to the [template sensor](/components/sensor.template/)'s `value_template:` to get the average of multiple sensors. {% raw %} ```yaml {{ ((float(states.sensor.kitchen_temperature.state) + float(states.sensor.living_room_temperature.state) + float(states.sensor.office_temperature.state)) / 3) | round(2) }} ``` {% endraw %} Sensors with an unknown state will be ignored in the calculation. If the unit of measurement of the sensors differs, the `min_max` sensor will go to an error state where the value is `UNKNOWN` and unit of measurement is `ERR`. ## {% linkable_title Configuration %} To enable the `min_max` sensor, add the following lines to your `configuration.yaml`: ```yaml # Example configuration.yaml entry sensor: - platform: min_max entity_ids: - sensor.kitchen_temperature - sensor.living_room_temperature - sensor.office_temperature ``` {% configuration %} entity_ids: description: At least two entities to monitor. The unit of measurement of the first entry will be the one that's used. All entities must use the same unit of measurement. required: true type: [list, string] type: description: "The type of sensor: `min`, `max`, `last` or `mean`." required: false default: max type: string name: description: Name of the sensor to use in the frontend. required: false type: string round_digits: description: Round mean value to specified number of digits. required: false type: integer default: 2 {% endconfiguration %}