--- layout: page title: "KNX Cover" description: "Instructions on how to integrate KNX covers with Home Assistant." date: 2017-06-18 12:00 sidebar: true comments: false sharing: true footer: true logo: knx.png ha_category: Cover ha_release: 0.48 ha_iot_class: "Local Polling" --- The `knx` cover platform is used as in interface with KNX covers. The `knx` component must be configured correctly, see [KNX Component](/components/knx). To use your KNX covers in your installation, add the following to your `configuration.yaml` file: ```yaml # Example configuration.yaml entry cover: - platform: knx name: "Kitchen.Shutter" move_long_address: '3/0/0' move_short_address: '3/0/1' position_address: '3/0/3' position_state_address: '3/0/2' travelling_time_down: 51 travelling_time_up: 61 ``` - **name** (*Optional*): A name for this device used within Home Assistant. - **move_long_address**: KNX group address for moving the cover full up or down. - **move_short_address**: (*Optional*) KNX group address for moving the cover short time up or down. - **position_address**: (*Optional*) KNX group address for moving the cover to the dedicated position. - **position_state_address**: (*Optional*) Separate KNX group address for requesting the current position of the cover. - **angle_address**: (*Optional*) KNX group address for moving the cover to the dedicated angle. - **angle_state_address**: (*Optional*) Separate KNX group address for requesting the current angle of cover. - **travelling_time_down**: (*Optional*) Time cover needs to travel down in seconds. Needed to calculate the intermediate positions of cover while traveling. Defaults to 25. - **travelling_time_up**: (*Optional*) Time cover needs to travel up in seconds. Needed to calculate the intermediate positions of cover while traveling. Defaults to 25. - **invert_position**: (*Optional*) Set this to true if your actuator report fully closed as 100% - **invert_angle**: (*Optional*) Set this to true if your actuator reports tilt fully closed as 100%