--- title: Integration - Riemann sum integral description: Instructions on how to integrate Integration Sensor into Home Assistant. ha_category: - Energy - Helper - Sensor - Utility ha_release: 0.87 ha_iot_class: Local Push ha_quality_scale: internal ha_codeowners: - '@dgomes' ha_domain: integration ha_config_flow: true ha_platforms: - sensor ha_integration_type: helper --- This integrations provides the [Riemann sum](https://en.wikipedia.org/wiki/Riemann_sum) of the values provided by a source sensor. The Riemann sum is an approximation of an **integral** by a finite sum. The integration sensors are updated upon changes of the **source**. Fast sampling source sensors provide more accurate results. In this implementation, the default is the Trapezoidal method, but Left and Right methods can optionally be used. {% include integrations/config_flow.md %} {% configuration_basic %} Name: description: The name the sensor should have. You can change it again later. Input sensor: description: The entity providing numeric readings to integrate. Integral method: description: Riemann sum method to be used. Precision: description: Round the calculated integration value to at most N decimal places. Metric prefix: description: Metric unit to prefix the integration result. Integration time: description: SI unit of time to integrate over. {% endconfiguration_basic %} ## YAML configuration Alternatively, this integration can be configured and set up manually via YAML as well. To enable the Integration sensor in your installation, add the following to your `configuration.yaml` file: ```yaml # Example configuration.yaml entry sensor: - platform: integration source: sensor.current_power ``` {% configuration %} source: description: The entity ID of the sensor providing numeric readings. required: true type: string name: description: Name to use in the frontend. required: false default: source entity ID integral type: string unique_id: description: An ID that uniquely identifies the integration sensor. Set this to a unique value to allow customization through the UI. required: false type: string round: description: Round the calculated integration value to at most N decimal places. required: false default: 3 type: integer unit_prefix: description: "Metric unit to prefix the integration result. Available units are `k`, `M`, `G` and `T`." required: false default: None type: string unit_time: description: "SI unit of time to integrate over. Available units are `s`, `min`, `h` and `d`." required: false default: h type: string method: description: "Riemann sum method to be used. Available methods are `trapezoidal`, `left` and `right`." required: false type: string default: trapezoidal {% endconfiguration %} In case you expect that your source sensor will provide several subsequent values that are equal, you should opt for the `left` method to get accurate readings. The unit of `source` together with `unit_prefix` and `unit_time` is used to generate a unit for the integral product (e.g. a source in `W` with prefix `k` and time `h` would result in `kWh`). Note that `unit_prefix` and `unit_time` are _also_ relevant to the Riemann sum calculation. ## Integration method Riemann Sum is a approximation of an integral by a finite sum and is therefore intrinsically inaccurate, nonetheless, depending on the method used, values can be more or less accurate. Regardless of the method used the integration will be more accurate if the source updates more often. If your source is not updated, neither will the Riemann Sum sensor, as all this integration does is calculate the next step in the event of a source update. ### Trapezoidal The `trapezoidal` method follows the [Trapezoidal rule](https://en.wikipedia.org/wiki/Trapezoidal_rule). This method is the most accurate of the currently implemented methods, **if** the source updates often, since it better fits the curve of the intrinsic source. ### Left The `left` method follows the [Left rule](https://en.wikipedia.org/wiki/Riemann_sum#Left_rule). The method **underestimates** the intrinsic source, but is extremely accurate at estimating rectangular functions which are very stable for long periods of time and change very rapidly (e.g. such as the power function of a resistive load can jump instantly to a given value and stay at the same value for hours). If your source keeps its state for long periods of time, this method is preferable to the `trapezoidal`. ### Right The `right` method follows the [Right rule](https://en.wikipedia.org/wiki/Riemann_sum#Right_rule). The method is similar to the left method, but **overestimates** the intrinsic source. Again it is only appropriate to be used with rectangular functions. ## Energy An integration sensor is quite useful in energy billing scenarios since energy is generally billed in kWh and many sensors provide power in W (Watts). If you have a sensor that provides you with power readings in Watts (uses W as `unit_of_measurement`, `device_class` of `power`), then you can use the `integration` sensor to track how much energy is being spent. Take the next manual YAML configuration as an example: ```yaml sensor: - platform: integration source: sensor.current_power name: energy_spent unit_prefix: k round: 2 ``` This configuration will provide you with `sensor.energy_spent` which will have your energy in kWh, as a `device_class` of `energy`.