Added more ebusd sensors. (#10398)

* Added more ebusd sensors.

* Fixed review item. Removed link to sources.

* Fixed spelling
This commit is contained in:
Oleksandr Omelchuk 2019-09-27 19:22:36 +03:00 committed by Franck Nijhof
parent 96f6ce0be5
commit 114e496055

View File

@ -28,7 +28,7 @@ host:
required: true
type: string
circuit:
description: The heating circuit name to monitor, e.g., 700.
description: The heating circuit name to monitor, e.g., '700', 'ehp' or 'bai'.
required: true
type: string
port:
@ -42,7 +42,7 @@ name:
required: false
default: ebusd
monitored_conditions:
description: List of condition to monitor.
description: List of conditions to monitor. Note that not all monitored_conditions listed here can be supported by your circuit. This integration maps limited set of keys to circuit specific ebusd values.
type: list
required: false
keys:
@ -112,4 +112,24 @@ monitored_conditions:
description: Power energy consumption from last month.
PowerEnergyConsumptionThisMonth:
description: Power energy consumption from the actual month.
HotWaterTemperature:
description: Hot water circuit temperature.
StorageTemperature:
description: Boiler temperature.
DesiredStorageTemperature:
description: Target boiler temperature.
OutdoorsTemperature:
description: Temperature used for weather dependent calculations.
AverageIgnitionTime:
description: Average flame ignition time (seconds).
MaximumIgnitionTime:
description: Maximum flame ignition time (seconds).
MinimumIgnitionTime:
description: Minimum flame ignition time (seconds).
ReturnTemperature:
description: Temperature returned into heater from water circuit.
DesiredFlowTemperature:
description: Target heat temperature.
FlowTemperature:
description: Out temperature.
{% endconfiguration %}