new NUT sensor 'output' variables (#5623)
* Added output variables to example Added example command line for 'upsc' to get list of NUT variables * Remove superfluous spaces
This commit is contained in:
parent
3c769726a7
commit
74d6bbec71
@ -65,46 +65,51 @@ sensor:
|
||||
type: list
|
||||
{% endconfiguration %}
|
||||
|
||||
### {% linkable_title Example %}
|
||||
### {% linkable_title Example %}
|
||||
|
||||
Given the following example output from NUT (your variables may differ):
|
||||
|
||||
```yaml
|
||||
'ups.timer.reboot': '0'
|
||||
'battery.voltage': '27.0'
|
||||
'ups.firmware.aux': 'L3 -P '
|
||||
'ups.mfr': 'American Power Conversion'
|
||||
'battery.runtime.low': '120'
|
||||
'ups.delay.shutdown': '20'
|
||||
'ups.load': '19'
|
||||
'ups.realpower.nominal': '600'
|
||||
'battery.charge.warning': '50'
|
||||
'battery.charge.low': '10'
|
||||
'ups.vendorid': '051d'
|
||||
'ups.timer.shutdown': '-1'
|
||||
'ups.test.result': 'No test initiated'
|
||||
'ups.firmware': '868.L3 -P.D'
|
||||
'battery.mfr.date': '2015/05/08'
|
||||
'ups.serial': '3B1519X19994 '
|
||||
'ups.productid': '0002'
|
||||
'battery.runtime': '2552'
|
||||
'battery.date': '2001/09/25'
|
||||
'battery.voltage.nominal': '24.0'
|
||||
'battery.type': 'PbAc'
|
||||
'ups.mfr.date': '2015/05/08'
|
||||
'ups.status': 'OL'
|
||||
'ups.model': 'Back-UPS RS1000G'
|
||||
'ups.beeper.status': 'disabled'
|
||||
'battery.charge': '100'
|
||||
'input.sensitivity': 'medium'
|
||||
'input.transfer.low': '88'
|
||||
'input.transfer.high': '147'
|
||||
'input.voltage': '121.0'
|
||||
'input.voltage.nominal': '120'
|
||||
'input.transfer.reason': 'input voltage out of range'
|
||||
$ upsc ups_name@192.168.11.5
|
||||
ups.timer.reboot: 0
|
||||
battery.voltage: 27.0
|
||||
ups.firmware.aux: L3 -P
|
||||
ups.mfr: American Power Conversion
|
||||
battery.runtime.low: 120
|
||||
ups.delay.shutdown: 20
|
||||
ups.load: 19
|
||||
ups.realpower.nominal: 600
|
||||
battery.charge.warning: 50
|
||||
battery.charge.low: 10
|
||||
ups.vendorid: 051d
|
||||
ups.timer.shutdown: -1
|
||||
ups.test.result: No test initiated
|
||||
ups.firmware: 868.L3 -P.D
|
||||
battery.mfr.date: 2015/05/08
|
||||
ups.serial: 3B1519X19994
|
||||
ups.productid: 0002
|
||||
battery.runtime: 2552
|
||||
battery.date: 2001/09/25
|
||||
battery.voltage.nominal: 24.0
|
||||
battery.type: PbAc
|
||||
ups.mfr.date: 2015/05/08
|
||||
ups.status: OL
|
||||
ups.model: Back-UPS RS1000G
|
||||
ups.beeper.status: disabled
|
||||
battery.charge: 100
|
||||
input.sensitivity: medium
|
||||
input.transfer.low: 88
|
||||
input.transfer.high: 147
|
||||
input.voltage: 121.0
|
||||
input.voltage.nominal: 120
|
||||
input.transfer.reason: input voltage out of range
|
||||
output.current: 1.10
|
||||
output.frequency: 60.20
|
||||
output.voltage: 121.50
|
||||
output.voltage.nominal: 120
|
||||
```
|
||||
|
||||
Use the values from the left hand column. Support is included for most values with 'ups', 'battery', and 'input' prefixes.
|
||||
Use the values from the left hand column. Support is included for most values with 'ups', 'battery', 'input' and 'output' prefixes.
|
||||
|
||||
```yaml
|
||||
sensor:
|
||||
|
Loading…