new NUT sensor 'output' variables (#5623)

* Added output variables to example
Added example command line for 'upsc' to get list of NUT variables

* Remove superfluous spaces
This commit is contained in:
Carl Chan 2018-06-30 09:42:29 -04:00 committed by Fabian Affolter
parent 3c769726a7
commit 74d6bbec71

View File

@ -65,46 +65,51 @@ sensor:
type: list
{% endconfiguration %}
### {% linkable_title Example %}
### {% linkable_title Example %}
Given the following example output from NUT (your variables may differ):
```yaml
'ups.timer.reboot': '0'
'battery.voltage': '27.0'
'ups.firmware.aux': 'L3 -P '
'ups.mfr': 'American Power Conversion'
'battery.runtime.low': '120'
'ups.delay.shutdown': '20'
'ups.load': '19'
'ups.realpower.nominal': '600'
'battery.charge.warning': '50'
'battery.charge.low': '10'
'ups.vendorid': '051d'
'ups.timer.shutdown': '-1'
'ups.test.result': 'No test initiated'
'ups.firmware': '868.L3 -P.D'
'battery.mfr.date': '2015/05/08'
'ups.serial': '3B1519X19994 '
'ups.productid': '0002'
'battery.runtime': '2552'
'battery.date': '2001/09/25'
'battery.voltage.nominal': '24.0'
'battery.type': 'PbAc'
'ups.mfr.date': '2015/05/08'
'ups.status': 'OL'
'ups.model': 'Back-UPS RS1000G'
'ups.beeper.status': 'disabled'
'battery.charge': '100'
'input.sensitivity': 'medium'
'input.transfer.low': '88'
'input.transfer.high': '147'
'input.voltage': '121.0'
'input.voltage.nominal': '120'
'input.transfer.reason': 'input voltage out of range'
$ upsc ups_name@192.168.11.5
ups.timer.reboot: 0
battery.voltage: 27.0
ups.firmware.aux: L3 -P
ups.mfr: American Power Conversion
battery.runtime.low: 120
ups.delay.shutdown: 20
ups.load: 19
ups.realpower.nominal: 600
battery.charge.warning: 50
battery.charge.low: 10
ups.vendorid: 051d
ups.timer.shutdown: -1
ups.test.result: No test initiated
ups.firmware: 868.L3 -P.D
battery.mfr.date: 2015/05/08
ups.serial: 3B1519X19994
ups.productid: 0002
battery.runtime: 2552
battery.date: 2001/09/25
battery.voltage.nominal: 24.0
battery.type: PbAc
ups.mfr.date: 2015/05/08
ups.status: OL
ups.model: Back-UPS RS1000G
ups.beeper.status: disabled
battery.charge: 100
input.sensitivity: medium
input.transfer.low: 88
input.transfer.high: 147
input.voltage: 121.0
input.voltage.nominal: 120
input.transfer.reason: input voltage out of range
output.current: 1.10
output.frequency: 60.20
output.voltage: 121.50
output.voltage.nominal: 120
```
Use the values from the left hand column. Support is included for most values with 'ups', 'battery', and 'input' prefixes.
Use the values from the left hand column. Support is included for most values with 'ups', 'battery', 'input' and 'output' prefixes.
```yaml
sensor: